Usage:
Challenger 35 (8DN, 8RD, ADK),
Challenger 45 (1DR, ABF, 3BK),
Challenger 55 (7DM, 6NN, AEN) Agricultural Tractors
Reference: Special Instruction REHS0456; "Installation of Flow Limiters and Compensator Tubes".
Description of Change: Improved flow controls ("flow limiters") are now available. The new flow limiters now have shaft seals. In addition, the flow limiters allow easier adjustment while the circuit is under pressure. Internally, the flow compensator spool dynamic response in Circuit No. 3 and Circuit No. 4 has been changed to provide better flow stability in speed-critical applications such as fan drive motors, air seeders, and air drills.
Adaptability: The improved flow limiters and flow compensator spools/springs were effective with Challenger 35 (8RD76, ADK330), Challenger 45 (ABF122, 3BK370), and Challenger 55 (6NN172, AEN461) Agricultural Tractors.
For complete installation instructions, refer to the reference special instruction at the beginning of this article.