Removal Procedure
Required Tools     | |||
Tool     | Part Number     | Part Description     | Qty     |
A     | 138-7573     | Link Bracket     | 1     |
NOTICE |
---|
Keep all parts clean from contaminants. Contaminants may cause rapid wear and shortened component life. |
NOTICE |
---|
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to Special Publication, NENG2500, "Caterpillar Dealer Service Tool Catalog" for tools and supplies suitable to collect and contain fluids on Caterpillar products. Dispose of all fluids according to local regulations and mandates. |
- Drain the raw water system.
Note: Refer to Disassembly and Assembly, "General Information (Reference Material)" for more information.
- Attach Tooling (A) and a suitable lifting device to auxiliary water pump (2). The weight of auxiliary water pump (2) is approximately 83 kg (182 lb).
Illustration 1 | g01430451 |
(X) Sea Water Inlet (Y) Sea Water Outlet |
- Remove bolts (1) and auxiliary water pump (2) .