- Engines:
- 3606 (S/N: 8RB)
- 3608 (S/N: 6MC)
- 3612 (S/N: 2NZ; 9FR; 9RC)
- 3616 (S/N: 1FN; 1PD)
- 3618 (S/N: 2MW)
The 203-7811 Engine Monitoring Control Group is the service replacement for the 146-3117 Monitoring Control and the 162-1662 Monitoring Control that are used in Marine Monitoring Systems (MMS). The 203-7811 Engine Monitoring Control Group uses Wonderware as the "Graphic Display Application".
The 203-7810 Engine Monitoring Control Group is the optional monitor that is used in the Marine Monitoring System II (MMS II) and the Generator Monitoring System (GMS). The 203-7810 Engine Monitoring Control Group uses the RSView as the "Graphic Display Application".
When these engine monitoring control groups are used as service replacements in the field, use the procedure that follows to register the software to the user. This procedure can be done when the engine monitoring control group is connected to the Programmable Logic Controller (PLC). This procedure can also be done when the engine monitoring control group is not connected to the PLC.
- Connect a keyboard that is compatible with the PS/2 style of connector. Connect electrical power to the monitor.
- Turn on the power.
- When you are prompted, accept the license agreement. Press the "Next" button.
- Enter the Microsoft Windows NT product identification number. This number is located on the right side of the computer. Press "Next".
- When the message indicates that the system could not complete the login, select "OK".
- Input "Administrator" for the login username. Input "3600" for the login password.
- After a successful login as "Administrator", do one of the items that follow:
- Restart the computer.
- Close all of the programs and use a different login username.
- Restart the computer.
- When the message indicates that the system could not complete the login, select "OK".
- Input "Operator" for the login username. Input "password" for the login password.
- After a successful login as "Operator", one of the items that follow will occur:
- Remove the keyboard. The setup is complete.
In applications that use Wonderware or RSView, the engine monitoring control group must be connected to the PLC in order for the data to be displayed.
After a successful login to the "Operator" account, the computer will automatically start and the computer will start the application in the "Operator" account. The automatic start-up can be bypassed by doing the operations that follow:
- Attach a keyboard.
- Hold the "shift" key in the down position while the start-up of the computer is initiated.