Voltage ... 24 V
Amperage ... 60 Amp
Note: Load the battery with a carbon pile 4C-4911 Battery Load Tester in order to get the maximum alternator output.
Polarity ... Negative ground
Rotation ... Either direction
Minimum full load current at 5000 rpm ... 112 Amp
Minimum full load current at 2000 rpm ... 63 Amp
Output voltage ... 28 ± 1 V
(1) Final installation torque for the flange nut ... 102 ± 7 N·m (75 ± 5 lb ft)
(2) (B+) terminal. Final installation torque for the nut ... 6.2 ± 0.6 N·m (55 ± 5 lb in)
Note: Use a 7/16 ring terminal for (B+) terminal.
(3) The peak voltage for (R) terminal must not be less than the output voltage for (B+) terminal.
(4) (D+) terminal. Final installation torque for the nut ... 2.25 ± 0.25 N·m (20 ± 2 lb in)
(5) Voltage regulator assembly
- Voltage setting ... No adjustment
- Permissible voltage range ... 27 to 29 V