3512 and 3516 EUI Engines and 784B, 785B, 789B and 793B Off-Highway Truck/Tractors Caterpillar


Sending Unit

Usage:

793B 1HL


Illustration 1g00506047

Table 1
INSPECTION CHART 
Bath Temperature   Constant Voltage  Series Resistance   Current Limits (mA)  Resistance  
54.4 °C (130 °F)  27.2  312 Ohms  3.6 to 4.5  5806 to 7264 Ohms 
115.6 °C (240 °F)  27.2  312 Ohms  30.3 to 32.5  524 to 586 Ohms 

The sensing portion of the sending unit must project at least 9 mm (0.3543 inch) into the fluid.

The resistance value of the sender unit is shown in table 1. The applied voltage and series resistance are specified in the table. Apply power to the sender unit for at least seven minutes before inspection.

Test the sending unit in a continuous flow bath.

Medium for the oil bath ... UCON oil spec 50-HB-280X
Flow rate of the oil bath ... 228.6 mm (9 inch) to 254 mm (10 inch) per second
Back to top