3054, 3054B and 3056 Marine Engines Caterpillar


Starting the Engine

Usage:

3056 CKS
Refer to the Owner's Manual of the OEM for your type of controls. Use the following procedure in order to start the engine.

  1. Place the transmission in NEUTRAL.

  1. Move the throttle to the low idle position.

  1. Turn the ignition switch to the ON position.

  1. Press the start button or turn the ignition switch to the START position in order to crank the engine. If the engine fails to start within 15 seconds, release the start button, or the ignition switch. Wait for two minutes in order to allow the starting motor to cool before attempting to start the engine again.

  1. As soon as the engine starts, release the start button, or the ignition switch.


    NOTICE

    Oil pressure should rise within 15 seconds after the engine starts. Do not increase engine rpm until the oil pressure gauge indicates normal. If oil pressure is not indicated on the gauge within 15 seconds, DO NOT operate the engine. STOP the engine, investigate and correct the cause.


  1. Allow the engine to idle for approximately five minutes. Idle the engine until the water temperature gauge has begun to rise. Check all gauges during the warm-up period.

    Note: Oil pressures and fuel pressures should be in the normal range on the instrument panel, if equipped. Do not apply a load to the engine or increase engine rpm until the oil pressure gauge indicates at least normal pressure. Inspect the engine for leaks and/or unusual noises.

  1. Operate the engine at low load until the coolant temperature reaches 60 °C (140 °F). Check the gauges during the warm-up period.
Back to top