Gerotor Motor - Disassemble
Disassembly Procedure
Show/hide table
NOTICE |
---|
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to Special Publication, NENG2500, "Caterpillar Tools and Shop Products Guide" for tools and supplies suitable to collect and contain fluids on Caterpillar products. Dispose of all fluids according to local regulations and mandates. |
- Make an identification mark along the length of the housing on the gerotor motor. Mark the orientation of each section of the motor. This procedure must be done in order to ensure correct assembly of the motor.
- Remove seven bolts (1) that secure cover (2) to the motor. Remove the cover from the motor.
Show/hide table
Illustration 1 | g00549974 |
- Remove seal (3) from cover (2) .
Show/hide table
Illustration 2 | g00679281 |
- Remove commutator ring (4) .
Show/hide table
Illustration 3 | g00679285 |
- Remove commutator (5) and seal (6) .
- Remove seal (7) from manifold (8) .
Show/hide table
Illustration 4 | g00679291 |
- Remove manifold (8) .
- Remove seal (9) from the bottom of manifold (8) .
Show/hide table
Illustration 5 | g00550167 |
- Remove rotor set (10) .
Show/hide table
Illustration 6 | g00679235 |
- Remove seal (11) from rotor set (10) .
Show/hide table
Illustration 7 | g00679253 |
- Remove plate (12) .
Show/hide table
Illustration 8 | g00679256 |
- Remove seal (13) from housing (16) .
Show/hide table
Illustration 9 | g00679245 |
- Remove intermediate shaft (14) .
- Remove thrust bearing (15) .
- Remove output shaft (17) from housing (16) .
Show/hide table
Illustration 10 | g00679243 |
Caterpillar Information System:
Generator Set Control Panel for Switchgear Conversion Clear/Mode Switch - Troubleshoot
P16, P20, P25, P28, P40 and P60 Pulverizers Gerotor Motor - Install
Generator Set Control Panel for Switchgear Conversion Charging System - Test
Generator Set Control Panel for Switchgear Conversion CID 0263 FMI 04 Sensor Power Supply Voltage Below Normal - Test
G3408 and G3412 Engines Governor Linkage
Generator Set Control Panel for Switchgear Conversion CID 0271 FMI 06 Alarm (Action) Current Above Normal - Test
G3408 and G3412 Engines Governor Control
G3408 and G3412 Engines Governor
3116 and 3126 Marine Engines Turbocharger - Inspect
G3408 and G3412 Engines Magneto
G3408 and G3412 Engines Gas Pressure Regulator
G3408 and G3412 Engines Flywheel
3606 and 3608 Engines General Information (Lubrication System)
3408E and 3412E Engines for Caterpillar Built Machines Fuel Transfer Pump
3054 and 3056 Industrial and Generator Set Engines Engine Oil Cooler - Remove
Generator Set Control Panel for Switchgear Conversion Component Location
SR4 HV and SR4B HV Generators Before Starting Engine
3054 Engine for Caterpillar Built Machines Housing (Front) - Remove
3054 Engine for Caterpillar Built Machines Housing (Front) - Install
3054 Engine for Caterpillar Built Machines Rocker Shaft and Pushrod - Remove
SR4 HV and SR4B HV Generators Walk-Around Inspection
3054 Truck Engine Rocker Shaft and Pushrod - Install
3054 Engine for Caterpillar Built Machines Rocker Shaft - Disassemble
Generator Set Control Panel for Switchgear Conversion Cycle Crank - Adjust