Illustration 1 | g01102594 |
Illustration 2 | g01102596 |
When the electric starting motor is viewed from the pinion end, the motor rotates in the following direction. ... Clockwise
No load conditions at 25 °C (77 °F)
- Speed ... 3300 rpm minimum
- Current draw ... 80 Amp maximum
- Voltage ... 23.5 V
- Current draw ... 80 Amp maximum
(1) Tighten the nut on the battery terminal to the following torque. ... 30.5 ± 3.5 N·m (22 ± 3 lb ft)
(2) Tighten the nut on the ground terminal to the following torque. ... 30.5 ± 3.5 N·m (22 ± 3 lb ft)
(3) Tighten the nut on the motor terminal to the following torque. ... 30.5 ± 3.5 N·m (22 ± 3 lb ft)
(4) Tighten to the following torque. ... 1.5 ± 0.5 N·m (13 ± 4 lb in)
(5) Tighten the nut on the switch terminal to the following torque. ... 2.25 ± 0.25 N·m (20 ± 2 lb in)
(6) Tighten the nut on the motor frame terminal to the following torque. ... 17.5 ± 2.5 N·m (13 ± 2 lb ft)
3E-0135 Solenoid
Current consumption at 25 °C (77 °F)
- Pull in windings at 24V ... 103 Amp
- Hold in windings at 24V ... 19 Amp