1991/04/15 Caterpillar


Simplified Battery Test Procedure SEHS7633-02 And Battery Test Sheet SEHS9326 Available{1401}

Usage:


SUPPLEMENT: 10/07/91

Service Magazine; April 15, 1991; Page 4; "Simplified Battery Testing Procedure SEHS7633-02 And Battery Test Sheet SEHS9326 Available". In COSA, use form G1052 only for testing batteries in accordance with Special Instruction SEHS7633-02. This was announced in the COSA General Letter, CSD No. 12 dated May 15, 1990. DO NOT use form SEHS9326.

Paragraph 3 and 4 of the article refer to an Open Circuit Voltage (OCV) of 12.40 as having sufficient charge to use, sell or load test the battery. This is correct providing it is a stabilized voltage. If the OCV was measured shortly after recharging, invariably the reading will be falsely high due to a surface charge on the plates. Remove the surface charge as described in Special Instruction SEHS7633-02 by applying a load of half the cold cranking amperes (cca) rating for 5 seconds. Allow the battery to recover and measure the OCV. If the OCV recovers to 12.40 or more, the battery can be put into use or load tested. If it does not, further charge the battery.

NOTE: Always use a digital voltmeter for all battery voltage checks.

NOTE: If testing 8 or 6 volt batteries, the equivalent OCV is 8.27 and 6.20 volts, respectively.

--------------- END SUPPLEMENT ---------------

Reference: Special Instructions: SEHS7633-02, "Battery Test Procedure" and SEHS9326, "Battery Test Sheet".Information Release Memo (IRM): PELE0187, BAT 91-4, "Simplified Battery Test Procedure"; PELE0172, BAT 90-7, "New Battery Test Tool Available" PELE0178, BAT 90-9A, "New Battery Load Tester".

A new Battery Test Procedure, SEHS7633-02, has been published. The new procedure covers all aspects of testing batteries. It also covers charging and warranty determination.

You can save time and money by using this new, simplified method of testing batteries. Instead of using a hydrometer to measure the specific gravity of the acid in each cell, you simply touch a voltmeter to the battery terminals. The voltmeter reading will tell you the open circuit voltage which indicates state of charge. Any reading of 12.4 volts or more (in a 12 volt battery) means there is sufficient charge to use, sell, or load test. Any reading less than 12.4 means a recharge is needed.

Once the battery is at a sufficient state of charge (12.4 or more), a load test can be performed to determine if the battery is good or bad. Connect the battery to a load tester. Set at 1/2 the cold cranking amp (CCA) rating from the Parts Sales Kit, PEKP9100. After 15 seconds, the voltage should be 9.5 or more (for a 12 volt battery). Any lower reading indicates a bad battery.

Use a digital voltmeter for measuring the battery's state of charge. Analog-type (moving needle) testers are not accurate enough for battery work. A fully charged battery will measure 12.7 volts; 12.4 volts indicates a 75% charge; and 12.0 indicates the battery is almost dead.

Never load test a battery that reads less than 12.4 volts. It will always test bad. When the battery is charged, it may test good.

A Battery Test Sheet, SEHS9326, is now available. It follows the same step-by-step procedure used in the Battery Test Procedure, SEHS7633-02. Use this sheet whenever claiming warranty on a battery.

New service tools recently released for battery work will also streamline your operation. They include a low-cost 4C6600 Voltmeter, a new 4C4911 Load Tester with build-in LCD meters, and 4C4920, 4C4921 and 4C4910Battery Chargers.

The 4C6600 Voltmeter was announced in IRM BAT90-7, PELE0172. The 4C4911 Load Tester was announced in IRM Bat90-9A, PELE0178. The battery chargers are all heavy-duty units. Use the 4C4920 Battery Charger for 110 volt AC input and charging six, eight, or 12 volt batteries. (Use the highest six volt setting for eight volt batteries.) Use the 4C4921 Battery Charger for 110 volt AC input and charging six, 12, or 24 volt batteries. The 24 volt setting on the 4C4921 Battery Charger can charge multiple 12 volt batteries connected in series in 24 volt electrical systems. This means you can charge batteries in machines without disconnecting the cables.

For 220 volt AC input and charging six, 12, or 24 volt batteries, use the 4C4910 Battery Charger. This charger will also be suitable for Europe and other regions that use a 220-240 volt AC power supply.

Remember to leave the vent caps on Cat batteries when charging or testing. They are protective caps designed to prevent an explosion. Never charge a frozen battery. If a battery feels cold to the touch, let it warm up before charging.

Caterpillar Information System:

1991/04/08 Remote Mounted Pressure Sensor Used In Temperature And Pressure Control Group In Electronic Modular Control Panel (ECMP){4490}
1991/04/08 New Carburetor Control Leakage Improves Idle Stability{1266}
1991/04/08 New Bolt Improves Retention Of Backplate To Housing Assembly In Turbocharger Cartridge Groups{1052,1053,1056,7553}
1991/04/08 Two Different Air Inlet Heater Control Modules Available{1090,1087,1058}
1991/04/01 Continuous Single Cylinder Misfire When Engine Is Under Load {1552}
1991/04/01 Remanufactured Type 1 Fuel Injector Assembly Available For 3500 Family Of Engines Equipped With UG8 Governors {1254,1264}
1991/04/01 Fuel Injection Pump Bushing Torque Increased {1253}
1991/04/01 New Performance Category For Engine Crankcase Oil {1318}
1991/04/01 Correct Position Of Lockwashers For Electrical Components With Screw Terminals {1400,7553}
1991/03/25 New Cylinder Blocks And Crankshafts Used{1201,1202,1231}
1991/03/25 New Shaft Bracket And Oil Supply Plug Used In Rocker Valve Shaft Assembly{1102,7553}
1991/03/18 New Air Compressor Crankshaft Has Improved Spline Lubrication{1803}
1991/04/15 New Specification For Transmission And Drive Train Oil (TDTO){0645,3004,3150,3179}
1991/04/15 New Auxiliary Water Pump Used; New Chart Lists Auxiliary Water Pump Group Numbers, Pulley Sizes, And Drive Belts{1371,1357,1384}
1991/04/15 New Shaft Bracket And Oil Supply Plug Used In Rocker Valve Shaft Assembly{1102,7553}
1991/04/15 New Oil Filter Element Assembly Used In Oil Filter Groups{1318}
1991/04/22 Procedure For Applying 1U8846 Gasket Maker{0648,7555}
1991/04/22 Procedure To Set Voltage Droop On SR 4 Generators With VR3 Voltage Regulators Using Resistive Load Bank{4475,4467}
1991/04/22 6L7896 Starting Motor (24V DC) Is No Longer Available From Caterpillar{1453}
1991/04/22 New Diagnostic Code 28 "Check Throttle Sensor Adjustment" Is On 1991 Engines{1900}
1991/04/22 Special Instruction, SEHS9340, Gives Jacket Water Heater Installation Procedures{1383}
1991/04/22 Improved Turbocharger Water Lines Group Eliminates Tube Cracking And Coolant Loss{1380,1052}
1991/04/22 Corrections For Systems Operation, Troubleshooting, And Specifications For 2301 Electric Governors For Generator Set And Industrial Engines, SENR2928-01{1289}
1991/04/29 Remove And Clean Flame Arrestors At Each Top End Overhaul{1058,1087}
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.