MID 039 - Machine Control Module (MCM)
CID 3454 - Autonomous Steering Enable Solenoid #1
FMI 05 - Current below normal
This diagnostic code is active when the MCM has determined the Autonomous Steering Enable Solenoid #1 (Primary EH Steer Pilot SOL [P1]) current is below normal.
Test Step 1. CHECK IF THE DIAGNOSTIC CODE IS STILL ACTIVE
- The keyswitch and the disconnect switch remain in the OFF position.
- Inspect the contacts of the harness connectors that are used in the solenoid circuit. Ensure that the contacts are secure. Clean all of the contacts in the harness connectors.
- Reconnect all harness connectors.
- Turn the disconnect switch and the keyswitch to the ON position.
- Operate the machine.
- Determine if the CID 3454 FMI 05 is active.
Expected Result:
The CID 3454 FMI 05 is active.
Results:
- YES - The CID 3454 FMI 05 is active.
Repair: CID 3454 FMI 05 is not expected to trigger in normal operation. If CID 3454 FMI 05 is active, follow the troubleshooting steps for MID 039 CID 3456 FMI 05.
STOP
- NO - The CID 3454 FMI 03 is not active. The problem does not exist at this time.
Repair: The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors. When disconnected and reconnected the short or poor connection was corrected. Resume normal machine operation.