Procedure to Restore the Residual Magnetic Field on Brushless Alternators{1405} Caterpillar


Procedure to Restore the Residual Magnetic Field on Brushless Alternators{1405}

Usage:

3304 04B
Engine:
3116 (S/N: 4PG3542-UP; 2MR277-UP)
3126B (S/N: BEJ154-UP; DCS739-UP)
3176C (S/N: 2AW375-UP)
3196 (S/N: 1DW483-UP)
3304 (S/N: 04B27163-UP; 23C2672-UP; 66D50755-UP; 67U10731-UP; 38S17134-UP; 4XB1081-UP; 10E2942-UP)
3306 (S/N: 64Z2682-UP; 85Z8567-UP)
3306B (S/N: 7JB8011-UP; 5GZ314-UP)
3408E (S/N: 7PR414-UP)
3412E (S/N: 4CR500-UP)
3508B (S/N: ZAD245-UP)
3512 (S/N: ZAF114-UP)
3512B (S/N: BLF176-UP)
3516 (S/N: 8TW1-UP)
3516B (S/N: FDN1322-UP; 7RN1953-UP; ZAP186-UP; 2JW414-UP; 8NW1-UP)
C-10 (S/N: BCX130-UP)
C-12 (S/N: BDL156-UP)
C-9 (S/N: CLJ306-UP)
C7 (S/N: JRA288-UP; JTF387-UP)
C9 (S/N: X3R1-UP)
G3408C (S/N: BAZ2218-UP)
G3520B (S/N: BGW1-UP)
Generator Set:
3406 GEN SET (S/N: 4ZR351-UP)
3406C GEN SET (S/N: KPS2010-UP; 9ES1-UP; LRX1-UP)
3456 GEN SET (S/N: BGA1-UP; CCB481-UP; CAH1-UP; CBX620-UP)
C15 GEN SET (S/N: PEC101-UP; X4R1-UP)
C15 PET GS ENG (S/N: PET101-UP)
C18 GEN SET (S/N: STD149-UP; PEJ101-UP; STM1-UP)
C27 GEN SET (S/N: DWB233-UP)
Industrial Engine:
3406B IND (S/N: 6TB5569-UP)
3406C IND (S/N: 3ER525-UP)
3406E IND (S/N: 6BR616-UP)
3412E IND (S/N: BDT4483-UP)
C-15 IND (S/N: BEM135-UP)
C-16 IND (S/N: BFM148-UP)
C13 INDUSTRIAL (S/N: LGK319-UP)
C15 IND (S/N: JRE102-UP)
C18 INDUSTRIAL (S/N: WJH101-UP)
C9 INDUSTRIAL (S/N: JSC108-UP; MBD146-UP)
Marine Engine:
3408C MARINE (S/N: 9ER311-UP)
Power Module:
PM3508 (S/N: BLM244-UP)

Introduction

This Special Instruction describes the procedure that is used in order to restore the residual magnetic field in the alternator.

Description

Charging problems may be encountered when you install brushless alternators that are new or remanufactured. The alternators may not begin to charge in some instances. The alternators may be considered faulty. Brushless alternators are self-excited. Self-excited alternators begin to charge at start-up, without the use of an external power source. Self-excited brushless alternators use residual magnetism in order to generate sufficient current to start the charging process. Charging problems with these alternators usually result when the residual magnetic field in the alternator is reduced below the level that is needed to excite the alternator. The following factors can lead to residual magnetism that is reduced:

  • Rough handling

  • Storage temperatures above approximately 38° C (100° F)

  • Extended storage periods of more than three to six months

  • Manufacturing tolerances in the alternator

  • Disassembled for repair

Procedure

Before returning or replacing a brushless alternator for failing to charge, use an external power source to restore the residual magnetic field. Use a jumper wire in order to connect the positive "+" output terminal of the alternator to the "R-Terminal" of the alternator for approximately two seconds. Refer to Illustration 1. This temporary connection should provide sufficient current from the vehicle batteries in order to restore the residual magnetic field in the alternator. If the alternator failed to charge due to one of the causes above, this procedure should restore residual magnetism. If the residual magnetism is restored, self-excitation will occur at the next start-up.




Illustration 1g01652497

Note: The unit must not be rotating while the field is being flashed. If you rotate the alternator during this procedure, you may damage the unit. The unit should be electrically connected. The unit must have battery voltage at "B+" and the unit must be properly grounded. Touch a jumper wire from "B+" to the "R-Terminal" for no more than two seconds. Be careful not to touch ground (case) with the ends of the wire. During the two second period, there should be a small flow of current of about two to five amperes, depending on the model number and system voltage. The current flow is between two to three amperes on 24 volt units. You should notice a tiny spark when the wire is touched to the "R-Terminal". If a large arc occurs when you flash the field, the "R-Terminal" of the alternator has a short to ground and the unit should not be used.

Caterpillar Information System:

G3500B Engines Engine Monitoring System
3000 Frame SR5 Electric Power Generation Rotor - Remove and Install
3000 Frame SR5 Electric Power Generation Bus Bar - Remove and Install
3000 Frame SR5 Electric Power Generation Bearing - Remove and Install - Rear Bearing - Remove and Install
3000 Frame SR5 Electric Power Generation Exciter - Remove and Install
2008/12/08 A New Cat Compression Brake Is Available. {1119, 1129}
3512B Engine Engine Crankcase Breather - Clean
345D, 349D and 349D2 Excavators and 345D MHPU and 349D MHPU Mobile Hydraulic Power Units Machine Systems Operator Console - Remove and Install
3512B Engine Product Lifting
3408E and 3412E Engines for Caterpillar Built Machines Gear Group (Rear)
345D, 349D and 349D2 Excavators and 345D MHPU and 349D MHPU Mobile Hydraulic Power Units Machine Systems Piston Motor (Hydraulic Fan) - Install
345D, 349D and 349D2 Excavators and 345D MHPU and 349D MHPU Mobile Hydraulic Power Units Machine Systems Piston Motor (Hydraulic Fan) - Remove
3512B Engine Air Shutoff - Test
G3500B Engines Air Inlet and Exhaust System Components
3512B Engine Auxiliary Water Pump - Inspect
Electrical Application and Installation Guide for the CX31-P600 and CX35-P800 Petroleum Transmissions {1400, 3030} Electrical Application and Installation Guide for the CX31-P600 and CX35-P800 Petroleum Transmissions {1400, 3030}
3412, 3412C, and 3412E Generator Set Engines Sensor Signal (Analog, Active) - Test
C13, C15, and C18 Tier 4 Final Engines Cylinder Liner
TH48-E70 Petroleum Transmission Lubricant Viscosities
Correct Usage of the 137-5541 Fuel Priming Pump As {1258, 1261} Correct Usage of the 137-5541 Fuel Priming Pump As {1258, 1261}
3000 Frame SR5 Electric Power Generation End Bracket - Remove
3000 Frame SR5 Electric Power Generation End Bracket - Install
2008/09/29 A Conversion Kit is Now Available to Convert a Digital Voltage Regulator (DVR) to a Caterpillar Digital Voltage Regulator (CDVR) {4467}
G3500B Engines Electronic Control System Operation
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.