Warming The Hydraulic System Caterpillar


Warming The Hydraulic System

Usage:

WHEEL LOADERSALL MEDIUM WHEEL LOADERS

Problem:

Extended use of any one relief valve while raising the hydraulic oil temperature for testing may cause damage to components due to the build-up of localized heating.

Solution:

Vary the relief valve usage and evenly circulate the oil when raising the temperature of the hydraulic system. Operate the control levers between the main and various line relief valves at maximum cylinder displacement. Cycle the cylinders to completely circulate the oil. Do not use any one relief valve for more than 10 seconds with the engine at high idle. After running the engine at high idle at the relief setting, run the engine between 1200 and 1500 RPM. Then change the direction of the cylinder actuation before you continue to warm the hydraulic system at high idle with the relief valve. This operation will evenly distribute the oil temperature and protect components from potential damage.

COPYRIGHT 1999 CATERPILLAR ALL RIGHTS RESERVED

Caterpillar Information System:

Roller Retainer Bolt Loosening Roller Retainer Bolt Loosening
4T (4T3130-4T3134) Series HPCU Filters May Delay Ability To Move Machine With Cold Oil 4T (4T3130-4T3134) Series HPCU Filters May Delay Ability To Move Machine With Cold Oil
Missing Rear Gear Train Idler Shaft Mounting Bolt Seals May Result In Oil Leaks Missing Rear Gear Train Idler Shaft Mounting Bolt Seals May Result In Oil Leaks
Reported Failtures Of Lift/Tilt Pressure Sensor Reported Failtures Of Lift/Tilt Pressure Sensor
Correct Service Replacement Part Numbers For 100-5778 Caterpillar Monitoring System Control Correct Service Replacement Part Numbers For 100-5778 Caterpillar Monitoring System Control
Alternator Drive Belt Retention Alternator Drive Belt Retention
Electrical Problems And Malfunctions Electrical Problems And Malfunctions
Actions That May Cause Inadvertent Dropping Of Pallet Forks Actions That May Cause Inadvertent Dropping Of Pallet Forks
Fan Drive Bearing Failures Fan Drive Bearing Failures
Bolt Loosening On Lower Articulated Hitch Bolt Loosening On Lower Articulated Hitch
New 9.6X Class Of Vims On Board Source Software Now Available New 9.6X Class Of Vims On Board Source Software Now Available
Seat Looseness - Conversion To Floor Mounted Controls Seat Looseness - Conversion To Floor Mounted Controls
Rotation Of Coupler Pins Causes Difficulty Coupling Work Tools Rotation Of Coupler Pins Causes Difficulty Coupling Work Tools
Transmission Serial Number Prefixes Transmission Serial Number Prefixes
Secondary Steering Pumps Installation Changed Secondary Steering Pumps Installation Changed
Water Drainage Holes For Loader Frame Water Drainage Holes For Loader Frame
Roof Assembly May Break During Transport Roof Assembly May Break During Transport
Speed Hold Control May Not Disengage Speed Hold Control May Not Disengage
Lack Of Spring Stiffness In Pilot Valve May Cause Decreased Prefeel Lack Of Spring Stiffness In Pilot Valve May Cause Decreased Prefeel
Clogged Atmospheric Pressure Sensors Clogged Atmospheric Pressure Sensors
A Nuisance Mid 82 CID 358 FMI 05 Service Code May Be Logged By The Implement Electronic Control Module A Nuisance Mid 82 CID 358 FMI 05 Service Code May Be Logged By The Implement Electronic Control Module
Undesired Machine Movement May Occur Under Certain Conditions Undesired Machine Movement May Occur Under Certain Conditions
Service Replacement Of Electronic Monitoring System (EMS) Module May Also Require Installation Of New Engine Software Service Replacement Of Electronic Monitoring System (EMS) Module May Also Require Installation Of New Engine Software
Air Filter Identification Film Air Filter Identification Film
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.