3512B Marine Auxiliary Engine Caterpillar


System Configuration Parameters

Usage:

3512B AAG
System Configuration Parameters are parameters that affect emissions, power of the engine, and other features. The parameters are programmed at the factory. In most cases, the parameters do not need to be changed. The System Configuration Parameters must be reprogrammed if an Electronic Control Module (ECM) is replaced and/or the engine rating is reprogrammed. System Configuration Parameters do not need to be reprogrammed if the Personality Module is replaced. Proper values for these parameters are available on the Caterpillar Electronic Technician (ET). Certain Configuration Parameters are also stamped on the Engine Information Plate.

Note: If the parameters that are protected with the factory passwords are changed, the Caterpillar warranty may be voided.

Engine Serial Number

The engine serial number should be programmed to match the engine information plate. The serial number is not programmed on a new ECM.

FRC Offset Value

The ECM determines a value that is based on the atmospheric pressure. The value is used to adjust the fuel ratio control. This will control the exhaust while the engine accelerates. An offset value of ± 25 may be used to adjust for customer preference, fuel quality or other factors that affect engine performance.

Note: This parameter may not be available on all applications.

Rated Fuel Position

This parameter is used to set engine power. A Factory Password is required to change this setting.

Table 1
Minimum     Default     Maximum    
Minimum Rack     Engine Dependent     Engine Dependent    

Low Idle

The parameter defines the lowest rpm level.

Table 2
Minimum     Default     Maximum    
810 rpm     900 rpm     1450 rpm    

Cooldown Speed

This parameter defines the engine rpm level when the ECS is placed in the STOP position.

Table 3
Minimum     Default     Maximum    
810 rpm     810 rpm     1800 rpm    

Cooldown Period

This parameter defines engine operation at the cooldown speed. Programming this parameter to 0 will disable this function.

Table 4
Minimum     Default     Maximum    
0 minutes     0 minutes     30 minutes    

Prelube Time

The parameter sets the amount of time for prelubrication. Programming this parameter to 0 will disable this function.

Table 5
Minimum     Default     Maximum    
0 seconds     0 seconds     210 seconds    

Crank Duration

The crank duration determines when the starting motors will be energized. The crank duration determines when the starting motors will be disengaged. Programming this parameter to 0 will prevent the ECM from engaging the starting motors.

Table 6
Minimum     Default     Maximum    
0 seconds     0 seconds     60 seconds    

Cranking Cycles

This parameter is the total number of crank cycles that can be performed.

Table 7
Minimum     Default     Maximum    
0     0     10    

Crank Terminate Speed

This parameter determines when the starting motor will disengage.

Table 8
Minimum     Default     Maximum    
100 rpm     400 rpm     500 rpm    

Air Shutoff

Programming the parameter to "OFF" will disable the air shutoff. This parameter should be programmed to "OFF" if the function is not being used or installed on this engine. This will prevent diagnostics from being logged.

Note: This parameter can only be read from the secondary ECM.

Table 9
Minimum     Default     Maximum    
DISABLED     ENABLED     ENABLED    

Caterpillar Information System:

3512B Marine Auxiliary Engine Engine Monitoring System
HDB Series and M1 Series Heavy Duty Brushless Alternators Alternator - Disassemble - M1 Series Alternator (35 Amp)
G3500 Engines Manifold Air Pressure Sensor
C15 Petroleum Generator Set Engines Electronic Unit Injector - Adjust
G3408C and G3412C Engines Connecting Rod Bearings - Remove and Install
G3406 Engine Starting System
3608 Engine Marine Monitoring System Connector Contact Description
3608 Engine Marine Monitoring System Central Processing Unit - Replace
G3406 Engine Grounding Practices
3608 Engine Marine Monitoring System Memory Module - Replace
3126E Truck Engines Exhaust Brake
3608 Engine Marine Monitoring System Battery - Replace
3054 and 3056 Industrial and Generator Set Engines Maintenance Interval Schedule
TK711, TK721, TK722 and TK732 Track Feller Bunchers Seat Belt - Replace
3412E, C30 and C32 Marine Engines Exhaust Manifold - Remove and Install
3512B Marine Auxiliary Engine Speed Control
HDB Series and M1 Series Heavy Duty Brushless Alternators Alternator - Assemble - M1 Series Alternator (35 Amp)
G3408C and G3412C Engines Balancer Group - Rear
3126B Marine Engines Sensors and Electrical Connectors
2001/08/01 Be Sure To Check The Counterweights On The Engine Crankshaft For Counterweight Sequence Numbers {1231}
HDB Series and M1 Series Heavy Duty Brushless Alternators Field Winding - Test
G3600 Engines Aftercooler
HDB Series and M1 Series Heavy Duty Brushless Alternators Capacitor - Test
3412E, C30 and C32 Marine Engines Engine Oil Filter Base - Remove
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.