Installation Procedure
Required Tools     | |||
Tool     | Part Number     | Part Description     | Qty     |
A     | 5P-0306     | Vacuum Transducer     | 1     |
FT-1115 | Vacuum Cap     | 1     | |
6V-4142 | Fitting     | 1     | |
5K-5068 | Fitting     | 1     |
Note: Cleanliness is an important factor. Before assembly, all parts should be thoroughly cleaned in cleaning fluid. Allow the parts to air dry. Wiping cloths or rags should not be used to dry parts. Lint may be deposited on the parts which may cause later trouble. Inspect all parts. If any parts are worn or damaged, use new parts for replacement.
NOTICE |
---|
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to Special Publication, NENG2500, "Caterpillar Tools and Shop Products Guide" for tools and supplies suitable to collect and contain fluids on Caterpillar products. Dispose of all fluids according to local regulations and mandates. |
- Position swing cushion valve (4) and install bolts (3) .
Note: The refrigerant receiver has been removed for photographic purposes.
Illustration 1 | g01167453 |
- Connect hose assemblies (2) .
Illustration 2 | g01167452 |
- Install panel (1) .
Illustration 3 | g01167434 |
- Remove Tooling (A) from the hydraulic tank.