Usage:
04Aug2015 |
After Failure Only | PRODUCT SUPPORT PROGRAM FOR REWORKING THE MULTI GENSET DATA LINK ETHERNET WIRING ON CERTAIN C15 GENERATOR SETS EQUIPPED WITH EMCP 4.4 |
|
1408 4490 | PS53005 |
NOTE: | Caterpillar’s obligations under this Service Letter are subject to, and shall not apply in contravention of, the laws, rules, regulations, directives, ordinances, orders, or statutes of the United States, or of any other applicable jurisdiction, without recourse or liability with respect to Caterpillar. |
NOTE: | This Program can only be administered after a failure occurs. The decision whether to apply the Program is made by the dealer. When reporting the repair, use "PS53005" as the Part Number and "7755" as the Group Number. Use "96" as the Warranty Claim Description Code and use "Z" as the SIMS Description Code. |
NOTE: | The information supplied in this service letter may not be valid after the termination date of this program. Do not perform the work outlined in this Service Letter after the termination date without first contacting your Caterpillar product analyst. |
TERMINATION DATE |
31Aug2017 |
PROBLEM
The existing multi genset data link (MGDL) network can intermittently communicate on certain C15 Generator Sets equipped with EMCP 4.4. If the existing wiring is incorrect it can cause the intermittent communication faults to occur. |
AFFECTED PRODUCT
Model | Identification Number |
C15 | T4A00452, 551-552, 562-576, 579-580, 582, 585, 609, 614-615, 625, 627-628, 630, 632, 640-641, 647, 661-663, 687, 690-696, 723, 739, 743, 750-759, 768-769, 781-782, 797-798, 813-816, 825, 836, 849-854, 889-891 |
PARTS NEEDED
No parts needed for this program |
ACTION REQUIRED
Inspect the wiring and determine if the two twisted pairs within the 9X-8922 Cable are isolated. Each twisted pair is isolated by a polyester foil to isolate noise from the other circuit. Refer to the attached Rework Procedure. |
SERVICE CLAIM ALLOWANCES
0-24 mo |
NOTE: This is a 0.5-hour job | ||||||
PARTS DISPOSITION
Handle the parts in accordance with your Warranty Bulletin on warranty parts handling. |
Important Safety Information Work safely. Most accidents that involve product operation, maintenance, and repair are caused by failure to observe basic safety rules or precautions. An accident can often be avoided by recognizing potentially hazardous situations before an accident occurs. A person must be alert to potential hazards. This person should also have the necessary training, skills, and tools in order to perform these functions properly. Safety precautions and warnings are provided in this instruction, on the product, and in this product's Operation and Maintenance Manual (OMM). If these hazard warnings are not heeded, bodily injury or death could occur to you or to other persons. Caterpillar cannot anticipate every possible circumstance that might involve a potential hazard. Therefore, the warnings in this publication, the warnings that are on the product, and the warnings that are in the OMM are not all inclusive. If a tool, a procedure, a work method, or operating technique that is not recommended by Caterpillar is used, the user must ensure that it is safe for the user and for other people to use. The user should ensure that the product will not be damaged or the product will be made unsafe by the operation, lubrication, maintenance, or the repair procedures that are used. WARNING: The generator set must be isolated electrically before and while the rework is performed. Follow the proper lockout tag out procedures to protect against the unexpected energizing or startup of the generator set. Failure to follow these warnings could result in injury to personnel during service. Attach a "Do Not Operate" warning tag to the machine start switch or the controls before you perform any service to the machine. |
1)Inspect the MGDL Ethernet network cable for proper isolation and termination of the two twisted pairs. The two twisted pairs are isolated by a polyester foil. Refer to Image 1.2.1. |
Image1.2.1 |
2)If the wires are not terminated correctly communication will be intermittent as the signal is corrupted. Make modifications to the existing wiring to correspond with Image 1.3.1 to correct the communication faults. |
Image1.3.1 |