Operation of Status Indicator
The Machine Security System (MSS) uses a status indicator that is mounted in the cab near the key start switch or in the dash cluster. The status indicator provides a visible alert of the presence of the security system. When the key start switch is first turned to the ON or START positions, and MSS is armed, a red light status indicator momentarily displays. This light provides a warning that the machine is armed with a security system.
Show/hide table
Illustration 1 | g01014891 |
Typical installation of the Status Indicator (1) Status Indicator |
The status of the MSS is displayed by the status indicator in accordance with Table 1. The operator can use the status indicator to determine the status of the system or for troubleshooting.
Show/hide table
Status Indicators(1) | Description |
---|---|
Red | The MSS is armed.(2) |
Green | The MSS is disarmed.
The green LED will remain ON 30 seconds after power down (Grace Period). After the 30 seconds have passed, the MSS automatically returns to the "armed" mode. |
Show/hide table
(1) | The LED's are illuminated during initial power-up in order to test the LED's. |
(2) | The red LED will remain ON while the key is in the ON position or until a valid key is read. |
Caterpillar Information System:
Machine Security System (MSS3i) Integrated System Overview
120 and 120 AWD Motor Grader Battery Disconnect Switch
Machine Security System (MSS3i) Integrated General Information
120 and 120 AWD Motor Grader Mirror - If Equipped
Energy Storage System Cell Level Faults
Aftertreatment Intake NOx Sensor Failing at Early Hours on Certain C13 Engines used in Claas Combines{191N} Aftertreatment Intake NOx Sensor Failing at Early Hours on Certain C13 Engines used in Claas Combines{191N}
Energy Storage System Module Level Faults
Energy Storage System System Level Faults
Energy Storage System Fault Codes Structure
Energy Storage System Harness and Cable - Replace
Energy Storage System Modem - Replace
Energy Storage System Subscriber Identity Module (SIM) Card - Replace
3512C Generator Set Engine Engine Oil Filter Housing - Disassemble
120 and 120 AWD Motor Grader Engine Shutdown Switch
Machine Security System (MSS3i) Integrated Key Information
Machine Security System (MSS3i) Integrated Scheduled Access - "Security System Bypass Times"
Machine Security System (MSS3i) Integrated Diagnostic Operation
Machine Security System (MSS3i) Integrated Protected Functions
Machine Security System (MSS3i) Integrated Service Operation Using Service Tool
Machine Security System (MSS3i) Integrated Electronic Control Module (ECM)
Procedure to Use the Correct Mounting Bolts with the 10R-2356 Flywheel As {1156} Procedure to Use the Correct Mounting Bolts with the 10R-2356 Flywheel As {1156}
Machine Security System (MSS3i) Integrated System Components
Machine Security System (MSS3i) Integrated Data Link
Machine Security System (MSS3i) Integrated General Information