Usage:

725C2 2L6
The Machine Security System can be programmed to disarm for a time period. The MSS can be set to disarm for different time periods on each day. Within these periods of time, any Caterpillar ® key (a standard key or an electronic key) will operate the machine.

Note: It is not possible to configure the "bypass times" for an individual electronic key. The "bypass times" are not associated to an individual electronic key.

"Security System Bypass Times" are time periods that can be set to disarm the Machine Security System automatically. An electronic key is not required during these periods. This feature can be used for the normal work shift of the machine. Outside the normal work shift, the Machine Security System would be armed. When the MSS is armed, an electronic key is required to start the machine. This feature would minimize the number of electronic keys that are needed.

Table 1
"Sunday Security System Bypass Start Time"  00:00 
"Sunday Security System Bypass Stop Time"  00:00 
"Monday Security System Bypass Start Time"  6:00 
"Monday Security System Bypass Stop Time"  18:00 
"Tuesday Security System Bypass Start Time"  6:00 
"Tuesday Security System Bypass Stop Time"  18:00 
"Wednesday Security System Bypass Start Time"  6:00 
"Wednesday Security System Bypass Stop Time"  18:00 
"Thursday Security System Bypass Start Time"  6:00 
"Thursday Security System Bypass Stop Time"  18:00 
"Friday Security System Bypass Start Time"  6:00 
"Friday Security System Bypass Stop Time"  12:00 
"Saturday Security System Bypass Start Time"   12:00 
"Saturday Security System Bypass Stop Time"  12:00 

Table 1 shows an example of "Security System Bypass". The "Start Time" is the time when the Machine Security System will disarm. The Machine Security System will return to the "armed" state at the "Stop Time". Between these two periods of time, any Caterpillar ® key will operate the machine. Thus, the MSS is disarmed during this time period.

All times are based on a 24 hour clock. For example, 6:00 am is 06:00 and 3:00 pm is 15:00. The Machine Security System will be disarmed during the times that are listed below: Monday through Thursday from 06:00 to 18:00

On Friday, the MSS is disarmed for only half of the workday. After 12:00 on Friday, the Machine Security System will be armed automatically. Operation will be restricted to operators with electronic keys that are authorized in the ECM on that machine. Refer to Table 1.

The Machine Security System is "armed" on the weekend. Because the "Start Time" and the "Stop Time" are set for the same time, the Machine Security System will be armed throughout the day.

See Testing and Adjusting, "Scheduled Access - Program" in order to program the security system bypass times.

Caterpillar Information System:

Machine Security System (MSS3i) Integrated Key Information
120 and 120 AWD Motor Grader Engine Shutdown Switch
3512C Generator Set Engine Engine Oil Filter Housing - Disassemble
Machine Security System (MSS3i) Integrated Operation of Status Indicator
Machine Security System (MSS3i) Integrated System Overview
120 and 120 AWD Motor Grader Battery Disconnect Switch
Machine Security System (MSS3i) Integrated General Information
120 and 120 AWD Motor Grader Mirror - If Equipped
Energy Storage System Cell Level Faults
Aftertreatment Intake NOx Sensor Failing at Early Hours on Certain C13 Engines used in Claas Combines{191N} Aftertreatment Intake NOx Sensor Failing at Early Hours on Certain C13 Engines used in Claas Combines{191N}
Energy Storage System Module Level Faults
Energy Storage System System Level Faults
Machine Security System (MSS3i) Integrated Diagnostic Operation
Machine Security System (MSS3i) Integrated Protected Functions
Machine Security System (MSS3i) Integrated Service Operation Using Service Tool
Machine Security System (MSS3i) Integrated Electronic Control Module (ECM)
Procedure to Use the Correct Mounting Bolts with the 10R-2356 Flywheel As {1156} Procedure to Use the Correct Mounting Bolts with the 10R-2356 Flywheel As {1156}
Machine Security System (MSS3i) Integrated System Components
Machine Security System (MSS3i) Integrated Data Link
Machine Security System (MSS3i) Integrated General Information
Machine Security System (MSS3i) Integrated Troubleshooting
Machine Security System (MSS3i) Integrated Key - Program
120 and 120 AWD Motor Grader Stopping the Engine if an Electrical Malfunction Occurs
Machine Security System (MSS3i) Integrated Scheduled Access - Program - Security System Bypass
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.