Cell Level Faults
Table 1 lists the cell level faults
Show/hide table
Fault Name | Description | Troubleshooting Steps |
Cell Anode/Cathode - DD2 Time Out | The cell exceeded the normal time for maintenance. | 1. Replace the cell. |
Cell Anode/Cathode - Relative Performance Low | The cell has a low performance when compared to the other cells in the module. The cell likely has an irreparable failure. | 1. Replace the cell. |
PIT Board - Anode FET Failure (Short) | There is a short circuit on the anode FET of the cell. | 1. Replace the cell.
2. Execute the open and short circuit detection command after replacement of the cell. |
PIT Board - Bypass FET Failure (Impedance) | There is a high impedance on the bypass FET of the cell. | 1. Replace the cell.
2. Execute the open and short circuit detection command after replacement of the cell. |
PIT Board - Bypass FET Failure (Open) | There is an open circuit on the bypass FET of the cell. | 1. Replace the cell.
2. Execute the open and short circuit detection command after cell replacement. |
PIT Board - Bypass FET Failure (Short) | There is a short circuit on the bypass FET of the cell. | 1. Replace the cell.
2. Execute the open and short circuit detection command after cell replacement. |
PIT Board - Cath./OEE FET Failure (Short) | There is a short circuit on the cathode or OEE FET of the cell. | 1. Replace the cell.
2. Execute the open and short circuit detection command after cell replacement. |
PIT Board - Cathode FET Failure (Impedance) | There is a high impedance on the cathode FET of the cell. | 1. Replace the cell.
2. Execute the open and short circuit detection command after cell replacement. |
PIT Board - General FET Failure | There is a FET failure on the cell. | 1. Replace the cell.
2. Execute the open and short circuit detection command after cell replacement. |
PIT Board - LIN Communication Failure | There is no LIN communication to/from the cell. | 1. Execute the address cells command.
2. If the fault persists, replace the cell. |
PIT Board - OEE FET Failure (Impedance) | There is a high impedance on the OEE FET of the cell. | 1. Replace the cell. |
PIT Board - OEE/Anode FET Failure (Open) | There is an open circuit on the OEE or anode FET of the cell. | 1. Replace the cell. |
Caterpillar Information System:
Aftertreatment Intake NOx Sensor Failing at Early Hours on Certain C13 Engines used in Claas Combines{191N} Aftertreatment Intake NOx Sensor Failing at Early Hours on Certain C13 Engines used in Claas Combines{191N}
Energy Storage System Module Level Faults
Energy Storage System System Level Faults
Energy Storage System Fault Codes Structure
Energy Storage System Harness and Cable - Replace
Energy Storage System Modem - Replace
Energy Storage System Subscriber Identity Module (SIM) Card - Replace
Energy Storage System Enclosure Filter - Replace
Energy Storage System Enclosure Fan - Replace
Energy Storage System Cathode Fan - Replace
Energy Storage System Communication Control - Replace
Energy Storage System Cell - Replace
120 and 120 AWD Motor Grader Mirror - If Equipped
Machine Security System (MSS3i) Integrated General Information
120 and 120 AWD Motor Grader Battery Disconnect Switch
Machine Security System (MSS3i) Integrated System Overview
Machine Security System (MSS3i) Integrated Operation of Status Indicator
3512C Generator Set Engine Engine Oil Filter Housing - Disassemble
120 and 120 AWD Motor Grader Engine Shutdown Switch
Machine Security System (MSS3i) Integrated Key Information
Machine Security System (MSS3i) Integrated Scheduled Access - "Security System Bypass Times"
Machine Security System (MSS3i) Integrated Diagnostic Operation
Machine Security System (MSS3i) Integrated Protected Functions
Machine Security System (MSS3i) Integrated Service Operation Using Service Tool