Enclosure Fan - Replace
Enclosure Fan Replacement Procedure
- Verify that the system is shut down and isolated from any other power source.
- Open the door that houses the enclosure fan that is to be replaced.
Show/hide table
Illustration 1 g06005837 - Unplug the pigtail cable from the enclosure fan harness but leave communication control side connected.
Show/hide table
Illustration 2 g06005844 - Remove the four mounting screws and washers. The fan cover and fan will loosen. Remove the fan.
- Install the replacement fan using the reverse procedure for removal.
Show/hide table
Illustration 3 g06005849 - Verify that the air flow direction and cable position are correct. The flow direction must be pointed out of the enclosure.
- Install the enclosure fan and cover using one of the screws and washers. Hand tighten.
- Install the remaining screws and washers and tighten.
- Connect the pigtail cable from the enclosure fan to the enclosure fan harness.
Caterpillar Information System:
Energy Storage System Cathode Fan - Replace
Energy Storage System Communication Control - Replace
Energy Storage System Cell - Replace
Energy Storage System Powering Off and On
Energy Storage System Safety Precautions
Energy Storage System Serviceable Parts and Tools
Energy Storage System Preventative Maintenance
Energy Storage System General Information
Energy Storage System Acceptance Test Procedure
Energy Storage System Site Load Discharge
Energy Storage System Initial Charge
Energy Storage System Communication Control Configuration
Energy Storage System Enclosure Filter - Replace
Energy Storage System Subscriber Identity Module (SIM) Card - Replace
Energy Storage System Modem - Replace
Energy Storage System Harness and Cable - Replace
Energy Storage System Fault Codes Structure
Energy Storage System System Level Faults
Energy Storage System Module Level Faults
Aftertreatment Intake NOx Sensor Failing at Early Hours on Certain C13 Engines used in Claas Combines{191N} Aftertreatment Intake NOx Sensor Failing at Early Hours on Certain C13 Engines used in Claas Combines{191N}
Energy Storage System Cell Level Faults
120 and 120 AWD Motor Grader Mirror - If Equipped
Machine Security System (MSS3i) Integrated General Information
120 and 120 AWD Motor Grader Battery Disconnect Switch