Illustration 1 | g00508708 |
(1) Torque for 36 bolts that fasten the impeller to the housing ... 50 ± 7 N·m (37 ± 5 lb ft)
(2) Torque for eight bolts that fasten the carrier assembly to the housing assembly ... 50 ± 7 N·m (37 ± 5 lb ft)
(3) Outside diameter of a new hub in the bearing area ... 60.258 ± 0.013 mm (2.3724 ± 0.0005 inch)
(3) Inside diameter of the new bearings in the flange assembly after installation ... 60.388 ± 0.038 mm (2.3775 ± 0.0015 inch)
(4) Depth for the bearings in the flange assembly ... 3.0 ± 0.5 mm (0.12 ± 0.02 inch)
(5) Torque for 16 bolts that fasten the turbine to the hub ... 50 ± 7 N·m (37 ± 5 lb ft)
(6) Torque for eight bolts that fasten the gear and the impeller to the hub ... 50 ± 7 N·m (37 ± 5 lb ft)
(7) Torque for the bolt that fastens the retainer to the shaft ... 120 ± 15 N·m (89 ± 11 lb ft)
Torque Converter Clearance Chart
Clearance Between the Components     | Diameter Across the Components     | Running (1)     | |
---|---|---|---|
(A) The Stator and Turbine     | new     | 0.49 to 1.01 mm (0.019 to 0.040 inch)     |
0.25 to 0.51 mm (0.010 to 0.020 inch)     |
max wear | 1.50 mm (0.59 inch)     |
0.75 mm (0.030 inch)     |
|
(B) The Stator and Impeller     | new     | 0.49 to 1.01 mm (0.019 to 0.040 inch)     |
0.25 to 0.51 mm (0.010 to 0.020 inch)     |
max wear | 1.50 mm (0.059 inch)     |
0.75 mm (0.030 inch)     |
( 1 ) | Half the clearance across the diameter |