Reference Material
Show/hide table
Single Phase Inverter Specifications (3 kW) | ||
---|---|---|
527-7543 Photovoltaic Inverter Gp | ||
DC Input | ||
Rated input power | 5300 W | |
Maximum input voltage | 600 V | |
Minimum start voltage | 125 V | |
Maximum input current | 11 A | |
AC Output | ||
Rated active power | 5000 W | |
AC voltage range | 180 V to 280 V | |
Rated power frequency / Rated grid voltage | 50 Hz / 230 V | |
Maximum output current | 22.8 A | |
Power factor | 1 |
Show/hide table
Single Phase Inverter Specifications (3 - 5 kW) | ||||
---|---|---|---|---|
524-8850 Photovoltaic Inverter Gp | 524-8851 Photovoltaic Inverter Gp | 524-3878 Photovoltaic Inverter Gp | 524-8852 Photovoltaic Inverter Gp | |
DC Input | ||||
Maximum power | 5500 W | 5500 W | 7500 W | 7500 W |
Maximum input voltage | 600 V | |||
Rated input voltage | 365 V | |||
Minimum input voltage | 100 V | |||
Minimum initial input voltage | 125 V | |||
Maximum input current | 15 A | |||
AC Output | ||||
Rated Power | 3000 W | 3680 W | 4000 W | 5000 W |
Nominal AC voltage / range | 220 V, 230 V, 240 V / 180 V to 280 V | |||
Rated power frequency / rated grid voltage | 50 Hz / 230 V | |||
Maximum output current | 16 A | 16 A | 22 A | 22 A |
Power factor at rated power | 1 |
Show/hide table
Single Phase Inverter Specifications (3 - 7 kW) | |||||||
---|---|---|---|---|---|---|---|
524-5583 Photovoltaic Inverter Gp | 524-3876 Photovoltaic Inverter Gp | 524-8854 Photovoltaic Inverter Gp | 524-8855 Photovoltaic Inverter Gp | 524-8856 Photovoltaic Inverter Gp | 524-8857 Photovoltaic Inverter Gp | ||
DC Input | |||||||
Maximum power | 208 V | 3100 W | 3450 W | 5150 W | 5400 W | 6900 W | 6900 W |
240 V | 3100 W | 4000 W | 5150 W | 6200 W | 7200 W | 7950 W | |
Maximum input voltage | 600 V | ||||||
Operating input voltage range | 100 V - 550 V | ||||||
Minimum input voltage | 100 V | ||||||
Minimum initial input voltage | 125 V | ||||||
Maximum input current | 10 A | ||||||
AC Output | |||||||
Rated power | 208 V | 3000 W | 3330 W | 5000 W | 5200 W | 6660 W | 6660 W |
240 V | 3000 W | 3800 W | 5000 W | 6000 W | 7000 W | 7680 W | |
AC voltage range | 208 V | 183 V - 229 V | |||||
240 V | 211 V - 264 V | ||||||
Rated grid frequency | 60 Hz / 50 Hz | ||||||
Maximum output current | 208 V | 14.5 A | 16 A | 24 A | 25 A | 32 A | 32 A |
240 V | 12.5 A | 16 A | 24 A | 25 A | 29.2 A | 32 A | |
Power factor at rated power | 1 |
Show/hide table
3-Phase Inverter Specifications (4 kW) | ||
---|---|---|
509-6889 Photovoltaic Inverter Gp Specifications | ||
DC Input | ||
Maximum DC power | 4200 W | |
Maximum input voltage | 750 V | |
Rated input voltage | 400 V | |
Minimum input voltage | 125 V | |
Initial input voltage | 150 V | |
Maximum input current (input A) | 15 A | |
Maximum input current (input B) | 15 A | |
Maximum short-circuit current per input | 20 A | |
Maximum reverse current from the inverter in the system | 0 A | |
AC Output | ||
Rated power | 4000 W | |
Maximum apparent AC power | 4000 VA | |
AC voltage range | 180 V to 280 V | |
Nominal AC current | At 220 V | 18.2 A |
At 240 V | 17.4 A | |
At 260 V | 16.7 A | |
Maximum output current | 22 A | |
Maximum output current under fault conditions | 34 A | |
Rated power frequency | 50 Hz / 60 Hz | |
Operating range | At AC power frequency 50 Hz | 45 Hz to 55 Hz |
At AC power frequency 60 Hz | 55 Hz to 65 Hz | |
Power factor at rated power | 1 | |
Displacement power factor cos(Φ) | 0.8 underexcited, 1 to 0.8 overexcited | |
Feed-in phases | 1 | |
Connection Phases | 1 | |
Maximum efficiency | 97% | |
European maximum efficiency | 96.4% |
Show/hide table
3-Phase Inverter Specifications (4- 7 kW) | |||
---|---|---|---|
509-6888 Photovoltaic Inverter Gp | 517-4492 Photovoltaic Inverter Gp | ||
DC Input | |||
Maximum DC power | 7300 W | 4200 W | |
Maximum input voltage | 600 V | 600 V | |
Rated input voltage | 400 V | 400 V | |
Minimum input voltage | 125 V | 125 V | |
Initial input voltage | 125 V | 150 V | |
Maximum input current | 30 A | 24 A | |
AC Output | |||
Rated power | At 208 V and 60 Hz | 6000 W | 4000 W |
At 240 V and 60 Hz | 7000 W | 4050 VA | |
Maximum apparent AC power | At 208 V and 60 Hz | 6000 VA | 208 V / 240 V |
At 240 V and 60 Hz | 7000 VA | 183 V / 229 V | |
AC voltage range | At 208 V and 60 Hz | 183 V to 229 V | 183 V to 229 V |
At 240 V and 60 Hz | 211 V to 264 V | 211 V to 264 V | |
Nominal AC current | At 208 V and 60 Hz | 29.2 A | 19.5 A |
At 240 V and 60 Hz | 29.2 A | 16.7 A | |
Maximum output current | 29.2 A | 20 A | |
Maximum output current under fault conditions | 40 A | 30 A | |
Rated power frequency | 60 Hz | 60 Hz | |
Operating range | 59.3 Hz to 60.5 Hz | 59.3 Hz to 60.5 Hz | |
Power factor at rated power | 1 | 1 | |
Connection conductor | 2 | 2 | |
Output connections | L1, L2, N, PE | L1, L2, N, PE | |
Efficiency | |||
Maximum efficiency | 97% | 97% |
Show/hide table
Single Phase Inverter Specifications (4 - 10kW) | ||||||
---|---|---|---|---|---|---|
527-7544 Photovoltaic Inverter Gp | 527-7545 Photovoltaic Inverter Gp | 527-7546 Photovoltaic Inverter Gp | 527-7547 Photovoltaic Inverter Gp | 527-7548 Photovoltaic Inverter Gp | ||
DC Input | ||||||
Maximum power | 4560 W | 3450 W | 5150 W | 5400 W | 6900 W | |
Maximum input voltage | 1000 V | |||||
Operating input voltage range | 200 V - 900 V | |||||
Minimum input voltage | 640 V | |||||
Minimum initial input voltage | 250 V | |||||
Maximum input current | 11 A | |||||
AC Output | ||||||
Rated power | 4000 W | 3330 W | 5000 W | 5200 W | 6660 W | |
AC voltage range | 183 V - 229 V | |||||
Rated grid frequency | 60 Hz / 50 Hz | |||||
Maximum output current | 14.5 A | 16 A | 24 A | 25 A | 32 A | |
Power factor at rated power | 1 |
Show/hide table
3-Phase Inverter Specifications (5 - 12 kW) | |||||
---|---|---|---|---|---|
509-6887 Photovoltaic Inverter Gp | 517-4486 Photovoltaic Inverter Gp | 517-4488 Photovoltaic Inverter Gp | 517-4490 Photovoltaic Inverter Gp | ||
DC Input | |||||
Maximum DC power | 7175 W | 12275 W | 10250 W | 8200 W | |
Maximum input voltage | 1000 V | 1000 V | 1000 V | 1000 V | |
Rated input voltage | 580 V | 580 V | 580 V | 580 V | |
Minimum input voltage | 150 V | 150 V | 150 V | 150 V | |
Initial input voltage | 188 V | 188 V | 188 V | 188 V | |
Maximum input current (input A) | 15 A | 18 A | 18 A | 15 A | |
Maximum input current (input B) | 10 A | 10 A | 10 A | 10 A | |
Maximum input current per string (input A) | 15 A | 18 A | 18 A | 15 A | |
Maximum input current per string (input B) | 10 A | 10 A | 10 A | 10 A | |
Maximum short-circuit current (input A) | 22.5 A | 25 A | 25 A | 22.5 A | |
Maximum short-circuit current (input B) | 15 A | 15 A | 15 A | 15 A | |
AC Output | |||||
Rated power | 7000 W | 12000 W | 10000 W | 8000 W | |
Maximum apparent AC power | 7000 VA | 12000 VA | 10000 W | 8000 VA | |
Rated grid voltage | ~3/N/PE, 230 V / 400 V | ~3/N/PE, 230 V / 400 V | ~3/N/PE, 230 V / 400 V | ~3/N/PE, 240 V / 400 V | |
AC voltage range | 160 V to 280 V | 160 V to 280 V | 160 V to 280 V | 160 V to 280 V | |
Nominal AC current | Current at 220 V | 10.2 A | 17.4 A | 14.5 A | 11.6 A |
Current at 230 V | 10.2 A | 17.1 A | 14.5 A | 11.6 A | |
Current at 240 V | 10.1 A | 16.7 A | 13.9 A | 11.1 A | |
Maximum output current | 10.2 A | 17.4 A | 14.5 A | 11.6 A | |
Maximum output current under fault conditions | 17 A | 30 A | 25 A | 20 A | |
Rated power frequency | 50 Hz | 50 Hz | 50 Hz | 50 Hz | |
AC power frequency | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz | |
Operating range | at AC power frequency 50 Hz | 45.5 Hz to 54.5 Hz | 45.5 Hz to 54.5 Hz | 45.5 Hz to 54.5 Hz | 45.5 Hz to 54.5 Hz |
at AC power frequency 60 Hz | 55.5 Hz to 64.5 Hz | 55.5 Hz to 64.5 Hz | 55.5 Hz to 64.5 Hz | 55.5 Hz to 64.5 Hz | |
Displacement power factor cos(ϕ) | 0.8 underexcited to 1 to 0.8 overexcited | 0.8 underexcited to 1 to 0.8 overexcited | 0.8 underexcited to 1 to 0.8 overexcited | 0.8 underexcited to 1 to 0.8 overexcited | |
Feed-in phases | 3 | 3 | 3 | 3 | |
Connection phases | 3 | 3 | 3 | 3 | |
Efficiency | |||||
Maximum efficiency | 98% | 98.2% | 98% | 98% | |
European efficiency | 97.5% | 97.9% | 97.6% | 97.6% |
Show/hide table
3-Phase Inverter Specifications (5 - 12 kW) | ||||
---|---|---|---|---|
524-8857 Photovoltaic Inverter Gp | 524-8858 Photovoltaic Inverter Gp | 524-8859 Photovoltaic Inverter Gp | ||
DC Input | ||||
Maximum DC power (1) | 5100 W | 6125 W | 9225 W | |
Maximum input voltage | 1000 V | 1000 V | 1000 V | |
Rated input voltage | 580 V | 580 V | 580 V | |
Minimum input voltage | 150 V | 150 V | 150 V | |
Initial input voltage | 188 V | 188 V | 188 V | |
Maximum input current (input A) | 11 A | 11 A | 15 A | |
Maximum input current (input B) | 10 A | 10 A | 10 A | |
Maximum input current per string (input A) | 11 A | 11 A | 15 A | |
Maximum input current per string (input B) | 10 A | 10 A | 10 A | |
AC Output | ||||
Rated power (2) | 5000 W | 6000 W | 9000 W | |
AC voltage range | 160 V to 280 V | 160 V to 280 V | 160 V to 280 V | |
Maximum output current | 7.3 A | 8.7 A | 13.1 A | |
Rated power frequency | 50 Hz | 50 Hz | 50 Hz | |
Power factor at rated load | 1 | |||
Efficiency | ||||
Maximum efficiency | 98% | 98% | 98% | |
European efficiency | 97.1% | 97.4% | 97.6% |
Show/hide table
(1) | When cos(ϕ) is 1 |
(2) | At 230 V, and 50 Hz |
Show/hide table
3-Phase Inverter Specifications (12 - 30 kW) | ||||
---|---|---|---|---|
492-5427 Photovoltaic Inverter Gp | 509-6886 Photovoltaic Inverter Gp | 515-0666 Photovoltaic Inverter Gp | ||
DC Input | ||||
Maximum DC power | 24500 W | 12250 W | 30800 W | |
Maximum input voltage | 1000 V | 1000 V | 1000 V | |
Rated input voltage | 712 V | 675 V | 720 V | |
Minimum input voltage | 150 V | 150 V | 150 V | |
Initial input voltage | 188 V | 188 V | 188 V | |
Maximum input current (input A) | 33 A | 33 A | 33 A | |
Maximum input current (input B) | 33 A | 33 A | 33 A | |
Maximum short-circuit current per string | 43 A | 43 A | 43 A | |
Maximum reverse current in the system for 0.01s | 1187 Apk | 1187 Apk | 28.8 Apk | |
AC Output | ||||
Rated power | 24000 W | 12000 W | 30000 W | |
Maximum apparent AC power | 24000 VA | 12000 VA | 30000 VA | |
Rated grid voltage | 480 V / 277 V | 480 V / 277 V | 480 V / 277 V | |
480 V | ||||
AC voltage range | 244 V to 305 V | 243.7 V to 304.7 V | 244 V to 305 V | |
Nominal AC current | Current at 277 V | 29 A | 14.5 A | 36.2 A |
Maximum output current | 29 A | 14.5 A | 36.2 A | |
Maximum residual output current for 0.01s | 142.5 Apk | 142.5 Apk | 79.8 Apk | |
Rated power frequency | 60 Hz | |||
Operating range | 59.3 Hz to 60.5 Hz | |||
Power factor at rated power | 1 | |||
Feed-in phases | 3 | |||
Connection phases | 3 | |||
Efficiency | ||||
Maximum efficiency | 98% |
Show/hide table
3-Phase Inverter Specifications (12 - 30 kW) | |||
---|---|---|---|
524-8862 Photovoltaic Inverter Gp | 524-8883 Photovoltaic Inverter Gp | ||
DC Input | |||
Maximum DC power | 15300 W | 20400 W | |
Maximum input voltage | 1000 V | 1000 V | |
Minimum input voltage | 150 V | 150 V | |
Initial input voltage | 188 V | 188 V | |
Maximum input current | 66 A | 66 A | |
AC Output | |||
Rated power | 15000 W | 20000 W | |
Rated grid voltage | 480 V / 277 V | 480 V / 277 V | |
AC voltage range | 244 V to 305 V | 243.7 V to 304.7 V | |
Maximum output current | 18 A | 24 A | |
Rated power frequency | 60 Hz | ||
Power factor at rated power | 1 | ||
Efficiency | |||
Maximum efficiency | 98% |
Show/hide table
3-Phase Inverter Specifications (20 kW) | ||
---|---|---|
520-9714 Photovoltaic Inverter Gp Specifications | ||
DC Input | ||
Rated input power | 20800 W | |
Maximum recommended input power | 23000 W | |
Maximum input voltage | 1000 V | |
Rated input voltage | 640 V | |
Initial input voltage | 300 V | |
Minimal feed-in voltage | 270 V | |
Maximum input current (input A) | 22 A | |
Maximum input current (input B) | 22 A | |
Turn-on power | 25 W | |
DC-switch | Optional | |
AC Output | ||
Power connection | 3-phase | |
Rated output power | 20000 W | |
Maximum output active power | 20000 W | |
Maximum output apparent power | 20000 VA | |
Rated grid voltage | 3/N/PE, 200/380 V | |
3/N/PE, 230/400 V | ||
3/N/PE, 240/415 V | ||
AC voltage range | 160 V to 300 V | |
Operating range | At AC power frequency 50 Hz | 45 Hz to 55 Hz |
At AC power frequency 65 Hz | 55 Hz to 65 Hz | |
Maximum output current | 30 A | |
Power factor | At 20% load | 0.97 |
At 100% load | 0.99 | |
Recommended AC circuit breaker | 300 V, 40 A, Type C circuit breaker | |
Evening loss | Less than 1 W | |
Standby loss | Less than 12 W |
Show/hide table
3-Phase Inverter Specifications (25 kW) | ||
---|---|---|
492-5426 Photovoltaic Inverter Gp Specifications | ||
DC Input | ||
Maximum DC power (1) | 25550 W | |
Maximum input voltage | 1000 V | |
Rated input voltage | 600 V | |
Minimum input voltage | 150 V | |
Initial input voltage | 188 V | |
Maximum input current (input A) | 33 A | |
Maximum input current (input B) | 33 A | |
Maximum short-circuit current per string | 43 A | |
Maximum reverse current in the system for maximum 1ms | 0 A | |
AC Output | ||
Rated power | 25000 W | |
Maximum apparent AC power | 25000 VA | |
Rated grid voltage | 230 V | |
AC voltage range | 180 V to 280 V | |
Nominal AC current | Current at 220 V | 36.2 A |
Current at 230 V | ||
Current at 240 V | ||
Maximum output current | 36.2 A | |
Maximum output current under fault conditions | 50 A | |
Rated power frequency | 50 Hz | |
AC power frequency | 50 Hz / 60 Hz | |
Operating range | at AC power frequency 50 Hz | 44 Hz to 55 Hz |
at AC power frequency 60 Hz | 54 Hz to 65 Hz | |
Power factor at rated power | 1 | |
Feed-in phases | 3 | |
Connection phases | 3 | |
Efficiency | ||
Maximum efficiency | 98 % | |
European efficiency | 98 % |
Show/hide table
(1) | When cos(ϕ) is 1 |
Show/hide table
3-Phase Inverter Specifications (30 - 40 kW) | |||
---|---|---|---|
513-4852 Photovoltaic Inverter Gp | 520-9716 Photovoltaic Inverter Gp | ||
DC Input | |||
Rated input power | 34000 W | 41000 W | |
Maximum recommended input power | 40800 W | 48000 W | |
Maximum input voltage | 1000 V | 1000 V | |
Rated input voltage | 620 V | 720 V | |
Initial input voltage | 300 V | 300 V | |
Minimum feed-in voltage | 270 V | 270 V | |
Maximum input current (input 1 and input 2) | 34 A | 38 A | |
Turn-on power | 25 W | 25 W | |
DC-switch | optional | optional | |
AC Output | |||
Power connection | 3-phase | 3-phase | |
Rated output power | 30000 W | 40000 W | |
Maximum output active power | 33000 W | 40000 W | |
Maximum output apparent power | 33000 VA | 40000 VA | |
Rated grid voltage | 3/N/PE, 220 V / 380 V | 3/PE/, 277/480 V | |
3/N/PE, 230 V / 400 V | |||
3/N/PE, 240 V / 415 V | |||
AC voltage range | 160 V to 300 V | 160 V to 300 V | |
Operating range | At AC power frequency 50 Hz | 45 Hz to 55 Hz | 45 Hz to 55 Hz |
At AC power frequency 65 Hz | 55 Hz to 65 Hz | 55 Hz to 65 Hz | |
Maximum output current | 48 A | 48 A | |
Power factor | At 20% load | 0.97 | 0.97 |
At 100% load | 0.99 | 0.99 | |
Recommended AC circuit breaker | 300 V, 63 A, Type C circuit breaker | 400 V, 63 A, Type C circuit breaker | |
Evening loss | Less than 1 W | Less than 1 W | |
Standby loss | Less than 12 W | Less than 12 W |
Show/hide table
3-Phase Inverter Specifications (50 kW) | ||
---|---|---|
527-7578 Photovoltaic Inverter Gp and 527-7579 Photovoltaic Inverter GpSpecifications | ||
DC Input | ||
Rated input power | 51000 W | |
Maximum recommended input power | 51000 W | |
Maximum input voltage | 1000 V | |
Rated input voltage | 150 V | |
Initial input voltage | 188 V | |
Maximum input current | 120 A | |
AC Output | ||
Rated output power | 50000 W | |
zMaximum output apparent power | 53000 VA | |
Rated grid voltage | 3/N/PE, 220 V / 380 V | |
3/N/PE, 230 V / 400 V | ||
3/N/PE, 240 V / 415 V | ||
AC voltage range | 160 V to 300 V | |
Operating range | At AC power frequency 50 Hz | 45 Hz to 55 Hz |
At AC power frequency 65 Hz | 55 Hz to 65 Hz | |
Maximum output current | 48 A | |
Power factor | At 20% load | 0.97 |
At 100% load | 0.99 | |
Recommended AC circuit breaker | 300 V, 63 A, Type C circuit breaker | |
Evening loss | Less than 1 W | |
Standby loss | Less than 12 W |
Caterpillar Information System:
3512B Generator Set Engines with Dynamic Gas Blending Injector Solenoid - Test
G3500H Generator Set Engine Fuel Differential Pressure Is High
3516B Generator Set Engines with Dynamic Gas Blending Electrical Power Supply - Test
3516B Generator Set Engines with Dynamic Gas Blending Sensor Signal (Analog, Passive) - Test
3516B Generator Set Engines with Dynamic Gas Blending Sensor Signal (Analog, Active) - Test
C175 Oil&Gas Offshore Engine Clean Fuel Module - Test
A New Turbocharger Is Now Used On Certain C175-16 Engines {1052, 1053} A New Turbocharger Is Now Used On Certain C175-16 Engines {1052, 1053}
C175 Oil&Gas Offshore Engine Fuel Rail Pressure Leakage Is High
797F and 797F XQ Off-Highway Trucks Machine Systems Oil Cooler Core (Brake) - Remove and Install
C175 Oil&Gas Offshore Engine Fuel Flow Is High
PM820, PM822, and PM825 Cold Planer Machine Systems Side Plate - Remove and Install - Right Hand
C2.4 Tier 4 Final Engines for Caterpillar Built Machines Fuel System
3600 Heavy Fuel Engines Engine Operation
C175 Oil&Gas Offshore Engine Electrical Power Supply - Test
New Software Is Used on Certain C9 and C13 Engines {1920} New Software Is Used on Certain C9 and C13 Engines {1920}
C175 Oil&Gas Offshore Engine Circuit Breaker - Test
Applied Failure Analysis and Reuse & Salvage Publications Have Been Updated To Aid in Identifying Cause of Inlet Valve Radial Crack on Certain C175 Engines {1100} Applied Failure Analysis and Reuse & Salvage Publications Have Been Updated To Aid in Identifying Cause of Inlet Valve Radial Crack on Certain C175 Engines {1100}
A New Transmission Output Speed Sensor Mounting Bracket is Now Used on Certain 797F Large Off-Highway Truck {1408, 1439, 3160, 3175, 3258} A New Transmission Output Speed Sensor Mounting Bracket is Now Used on Certain 797F Large Off-Highway Truck {1408, 1439, 3160, 3175, 3258}
G3512 Generator Set Engine Aftercooler - Disassemble
PM820, PM822, and PM825 Cold Planer Machine Systems Side Plate - Remove and Install - Left Hand
Instructions for Installing Connector Lock Wires on Off-Highway Trucks {1401, 1402, 1408} Instructions for Installing Connector Lock Wires on Off-Highway Trucks {1401, 1402, 1408}
Applied Failure Analysis and Reuse & Salvage Publications Have Been Updated to Aid in Identifying Cause of Liner Cuff Cracking Certain C175 Generator Set Engines {1000, 1216} Applied Failure Analysis and Reuse & Salvage Publications Have Been Updated to Aid in Identifying Cause of Liner Cuff Cracking Certain C175 Generator Set Engines {1000, 1216}
Special Instruction, "Instructions for Installing Connector Lock Wires on Off-Highway Trucks" is Now Available {1401, 1402, 1408} Special Instruction, "Instructions for Installing Connector Lock Wires on Off-Highway Trucks" is Now Available {1401, 1402, 1408}
G3512 Generator Set Engine Aftercooler - Assemble