Sub-Base Tank Water Retention Rework for Certain C15, C18, and C9 Generator Sets{1273} Caterpillar


Sub-Base Tank Water Retention Rework for Certain C15, C18, and C9 Generator Sets{1273}

Usage:

C15 C5E
Generator Set:
C15 GEN SET (S/N: C5E1-UP; NAP1-UP)
C18 GEN SET (S/N: EKW1-UP; NAW1-UP)
C9 GEN SET (S/N: NBP1-UP; NGP1-UP)

Introduction

The problem that is identified below does have a permanent solution. Use the solution detailed below to correct the issue.

Important Safety Information

Work safely. Most accidents that involve product operation, maintenance, and repair are caused by failure to observe basic safety rules or precautions. An accident can often be avoided by recognizing potentially hazardous situations before an accident occurs.

A person must be alert to potential hazards. This person should also have the necessary training, skills, and tools in order to perform these functions properly.

Safety precautions and warnings are provided in this instruction, on the product, and in this product's Operation and Maintenance Manual (OMM). If these hazard warnings are not heeded, bodily injury or death could occur to you or to other persons. Caterpillar cannot anticipate every possible circumstance that might involve a potential hazard.

Therefore, the warnings in this publication, the warnings that are on the product, and the warnings that are in the OMM are not all inclusive. If a tool, a procedure, a work method, or operating technique that is not recommended by Caterpillar is used, the user must ensure that it is safe for the user and for other people to use.

The user should ensure that the product will not be damaged or the product will be made unsafe by the operation, lubrication, maintenance, or the repair procedures that are used.

Problem

Water retention may be a concern on certain in-line six generator sets with sub-base tanks.

Solution

Introduce drain holes in sub-base tank rails as an outlet for water.

The generator set must be isolated electrically before and while the rework is performed.




Illustration 1g03564320

Follow the proper lockout tag out procedures against the unexpected energizing or startup of the generator. Failure to follow these warnings could result in injury to personnel during service. Attach a "Do Not Operate" warning tag to the machine start switch or the controls before you perform any service to the machine.

Refer to Illustration 2 and perform the following rework procedure.




Illustration 2g03882264

(A) See detailed view of area

(B) Radius 5 mm (0.20 inch)

(C) Diameter 6 mm (0.24 inch)

(D) 8 mm (0.31 inch)

(E) 90.24 mm (3.55 inch)

(F) 98.24 mm (3.87 inch)

(G) Drill hole every 1000 mm (39.37 inch) (both sides)

  1. Measure from bottom of base rail to top of tank to get dimension (F). 98.24 mm (3.87 inch) in this example.

  1. Subtract 8 mm (0.3 inch) from dimension (F) and mark location for drilling hole. 90.24 mm (3.55 inch) in this example.

  1. Using a 6 mm (0.2 inch) drill bit, drill hole through rail to allow water to drain.

  1. Drill four holes at same dimension along both rails every 1000 mm (39.4 inch).

Caterpillar Information System:

C7.1 Commercial Marine Engine Flywheel Housing - Inspect
G3600 A4 Engines Maintenance Interval Schedule - G3600 Wellhead or Natural Gas Engines with a 7.6 :1 Compression Ratio
EMCP 4.4 Supervisory Control Panel Control Panel
EMCP 4.4 Supervisory Control Panel Plate Locations and Film Locations
EMCP 4.4 Supervisory Control Panel Model View Illustrations
EMCP 4.4 Supervisory Control Panel Electrical System
EMCP 4.4 Supervisory Control Panel Safety Messages
EMCP 4.4 Supervisory Control Panel Fire Prevention and Explosion Prevention
EMCP 4.4 Supervisory Control Panel Control Panel - Inspect/Test
797F Off-Highway Truck Field Assembly Walkway - Install
Some Reman Injectors Have Been Labeled With The Incorrect Part Number{1254, 1290} Some Reman Injectors Have Been Labeled With The Incorrect Part Number{1254, 1290}
320D3 and 323D3 Excavators Machine System Specifications Cab Window
C7.1 Commercial Marine Engine Gear Group - Inspect
C7.1 Commercial Marine Engine V-Belt - Test
Energy Storage System Safety
Energy Storage System Plate Locations and Film Locations
2015/09/11 New Product Link Software for PL300 Is Now Available for All Cat® Products {7606, 7620}
WS273 XD, WS305 XD, WSF273 XD, WSF305 XD, WSP273 and WSP305 Well Stimulation Pumps Fluid End - Remove and Install
XQ35 Rental Generator Set Product Lifting
C7.1 Marine Engine Event Codes
3516E Generator Set Engine Air Inlet and Exhaust System Operation
3516E Generator Set Engine Turbocharger
Crankshaft Bearing Housing Assembly Instructions for Well Stimulation Pumps {1202, 5070} Crankshaft Bearing Housing Assembly Instructions for Well Stimulation Pumps {1202, 5070}
3516B Generator Set Engines with Dynamic Gas Blending Test Tools for the Cooling System
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.