UPSB505 Uninterruptible Power Supply UPS Battery - 50Hz Caterpillar


General Information

Usage:

UPSB 505 YTM

General Description




Illustration 1g02559160

UPSB505 cabinet




Illustration 2g02559480

UPS display

The 50 Hz battery uninterruptible power supply (UPS) is a three-phase double conversion UPS, designed for flexibility to meet a wide range of application requirements.

The 50 Hz battery UPS offers many options to allow for customizing a solution to meet the unique specifications of the customer. The options that are offered include, but are not limited to the following:

  • Adjacent and remote battery cabinets

  • Parallel system bypass cabinets

  • Variety of communication cards

Description of Information

This manual provides the following information:

  • Detailed 3-dimensional views of system components

  • Troubleshooting

  • Preventive maintenance

  • System checks

  • Testing and Adjusting procedures

Safety

Ensure that all safety precautions are followed to protect personnel and equipment before performing any operational or service procedures on the UPS.

ReferenceOperations and Maintenance Manual, SEBU8275, "Safety Signs and Labels, General Hazard Information, Fire Prevention, and Explosion Prevention"

Operation and Maintenance Manual

Operation and Maintenance Manual, SEBU8275 contains detailed instruction for the following:

  • Personnel and equipment safety

  • Installation guidelines and procedures

  • Equipment specifications

  • Operating procedures

  • General service procedures

Preventive Maintenance

Always follow the preventive maintenance procedure. The listed preventive maintenance procedures are used to ensure the following:

  • The equipment is serviced uniformly.

  • The equipment is configured properly.

  • The equipment is in proper operating condition.

All preventive maintenance is to be performed only by qualified technicians who have been trained to maintain the product. Preventive maintenance procedures include the following:

Basic Preventive Maintenance - These routines are performed on a minimum of a yearly basis.

Advanced Preventive Maintenance - These routines are performed as needed and for troubleshooting the system.

Complete all maintenance for power distribution equipment that is upstream of the UPS first. Servicing the upstream equipment first will ensure that there will not be any changes to the infrastructure for the power distribution after servicing the UPS.

Before starting these tests, complete the following:

  • Place the upstream disconnects in the ON position. The upstream disconnects are now closed.

  • Ensure that the system is configured to operate in Test Mode.

Test Mode

Test Mode consists of the following:

  • Place the MAINS 1 (Q1) input switch in the ON position. The MAINS 1 input switch is now closed.

  • Place the MAINS 2 (Q4S) input switch in the ON position. The MAINS 2 input switch is now closed.

  • Place the output switch in the ON position. The output switch is now closed.

  • Place the battery disconnects in the ON position. The battery disconnects are now closed.

  • Place the internal maintenance bypass switch in the OFF position. The internal maintenance bypass switch is now open.

If any conditions do not occur, troubleshoot the fault and correct the issue. Verify that the operations and alarm functions of the UPS are correct.

Caterpillar Information System:

CG137-08 and CG137-12 Engines Product Lifting
XQ125 Generator Set Fuel Tank Water and Sediment - Drain
Additional Procedure when Replacing the Engine, ECM, or CEM Tier 4 Engines{1000, 108D, 108F, 1901} Additional Procedure when Replacing the Engine, ECM, or CEM Tier 4 Engines{1000, 108D, 108F, 1901}
C13, C15, and C18 Tier 4 Final Engines Speed/Timing Sensor
C13 Tier 4 Final Engines Solenoid Valve - Air Control Valve Gp
C13, C15, and C18 Tier 4 Final Engines Speed/Timing Sensor
3500 Engines Engine Oil Cooler Bypass and Cooling Jet Sequence Valves
3500B Engines for Caterpillar Built Power Modules Engine Oil Cooler Bypass and Cooling Jet Sequence Valves
C175-16 Locomotive Engine Cylinder Head Valves
CG137-08 and CG137-12 Engines Plate Locations and Film Locations
Network Management Card and Network Management Card with Environmental Monitoring for the UPSB505 Uninterruptible Power Supply Environmental Monitoring
Network Management Card and Network Management Card with Environmental Monitoring for the UPSB505 Uninterruptible Power Supply UPS Monitor and Configure
2011/08/26 A New Wiring Harness Is Used On Certain Commercial Engines {1408, 1900}
3516C IMO III Petroleum Engines Engine Oil Cooler - Remove
UPSB505 Uninterruptible Power Supply UPS Battery - 50Hz Component Location
C15 and C18 Industrial Engines Electric Starting Motor
3500 Engines Engine Oil Filter
C13, C15, and C18 Generator Set Engines Turbocharger
C175-16 Locomotive Engine Cylinder Liner
C15 and C18 Industrial Engines Electric Starting Motor
C15 and C18 Petroleum Engines Turbocharger
2011/08/23 Introduction of Radiator Protection Screen on C4.4 and C4.4 (Mech) Engines {1353}
C15 and C18 Engines for Caterpillar Built Machines Electric Starting Motor
C9.3 Tier 4 Final Engines Engine Oil Filter Base
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.