Illustration 1 | g01501613 |
When the electric starting motor is viewed from the pinion end, the motor rotates in the following direction. ... Clockwise
Mount the electric starting motor in a position that places the solenoid assembly no less than the following angle above the horizontal. ... 15 Degrees
Specifications
- System voltage ... 24 V
No load performance at
- Speed ... 6950 ± 1650rpm
- Current ... 115 ± 25 amp
- Voltage ... 23 V
- Current ... 115 ± 25 amp
Operating temperature range of the starting motor ...
(B) Clearance between the pinion and the housing is the following value. ...
(1) Final installation torque for the ground terminal nut ...
(2) Final installation torque for the ground terminal nut ...
Note: The switch terminal must be insulated with heat shrink tubing. Do not use molded terminals.
(3) Final installation torque for the switch terminal nut ...
(4) Final installation torque for the motor terminal nut ...
Note: A maximum of three cable terminals or wire terminals may be used with the battery terminal nut. A maximum of two of the terminals may be equal to or greater than 0 AWG.
(5) Final installation torque for the battery terminal nut ...
(6) Final installation torque for the motor frame terminal nut ...