Electronic Modular Control Panel II (EMCP II) Caterpillar


Starting Motor Remains Engaged (for EUI and PEEC Engines)

Usage:

3412C 4BZ
System Operation Description:

The starting motor remains engaged after the engine has started.




Illustration 1g00518564

Schematic For Starting Motor Relay (SMR) On "PEEC" Engines




Illustration 2g00680589

Schematic For Starting Motor Relay (SMR) On "EUI" Engines

Test Step 1. CHECK THE SETPOINTS.

This test step checks the following setpoints: P11 (crank terminate speed), P17 (total cycle crank time) and P18 (cycle crank time).

  1. View the setpoints and make a note of setpoints P11, P17 and P18. See Systems Operation, "Engine/Generator Setpoint Viewing OP2".

  1. Compare the setpoints with the specified setpoints of the particular generator set. The default value for P11 is 400 rpm. The default value for P17 is 90 seconds. The default value for P18 is 10 seconds.

Note: Engines that are equipped with prelube pumps may require cycle crank times (setpoint P18) of 30 seconds or more.

Expected Result:

The setpoint value that is being viewed should match the specified setpoint value.

Results:

  • OK - The setpoint is correct. Proceed to test step 2.

  • NOT OK - The setpoint that is being viewed does not agree with the specified setpoint.

    Repair: Reprogram setpoints P11, P17 and P18. See Systems Operation, "Engine/Generator Programming OP5-0".

    Stop.

Test Step 2. CHECK THE START FUNCTION OF THE ENGINE.

The following procedure will require checks to be made during simulated engine starting. Disable the fuel system.

  1. Disable the fuel shutoff solenoid or the PEEC in order to prevent the engine from starting but not from cranking. To disable the EUI engine ECM, remove the J1-40 pin connector.

  1. Prepare to manually stop the engine from cranking, if necessary. Turn the battery disconnect switch to the OFF position or shut the engine off by using mechanical means.

  1. Turn the engine control switch (ECS) to the START position. Allow the engine to crank.

  1. Turn the ECS to the OFF/RESET position.

Expected Result:

The engine should stop cranking.

Results:

  • OK - The engine does not crank. Proceed to test step 6.

  • NOT OK - The engine continues to crank. Proceed to test step 3.

Test Step 3. CHECK THE START FUNCTION OF THE ENGINE.

  1. The conditions of the previous step remain. The fuel system is disabled. The engine is cranking.

  1. While the engine is still cranking, push the emergency stop push button.

Expected Result:

The engine should stop cranking.

Results:

  • YES - The engine does not crank.

    Repair: Check the wire on "RM-18" of the relay module for a short to +battery. Repair the short or replace the harness. If a short is not found, replace the relay module. See Testing And Adjusting, "Relay Module - Replace".

    Stop.

  • NO - The engine continues to crank. Proceed to test step 4.

Test Step 4. CHECK THE START FUNCTION OF THE ENGINE.

  1. The conditions of the previous step remain. The fuel system is disabled. The engine is cranking.

  1. Stop the engine. Turn the battery disconnect switch to the OFF or shut the engine off by using mechanical means.

  1. Remove all wires from TS1-25 in the generator housing. For dual starting motors, remove all wires from TS1-26.

  1. Turn the ECS to START. Attempt to crank the engine.

Expected Result:

The engine should not crank.

Results:

  • OK - The engine does not crank.

    Repair: The "SMS" or related wiring has failed. Troubleshoot the "SMMS" and the related wiring. See the Generator Set Wiring Diagram in Testing And Adjusting, "Schematics & Wiring Diagrams".

    Stop.

  • NOT OK - The engine continues to crank. Proceed to test step 5.

Test Step 5. CHECK THE START FUNCTION OF THE ENGINE.

  1. The conditions of the previous step remain. The fuel system is disabled. The engine is cranking.

  1. Stop the engine. Turn the battery disconnect switch to OFF or shut the engine off by using mechanical means.

  1. Disconnect the "B+" wire on the pinion solenoid of the starting motor.

  1. Turn the ECS to START and attempt to crank the engine.

Expected Result:

The engine should not crank.

Results:

  • OK - The engine does not crank.

    Repair: On "PEEC" engines, wire 052-125 or 125-152 in the engine harness is shorted to the battery. On "EUI" engines, wire 304-WH or 314-PU in the engine harness is shorted to the battery. Troubleshoot the wiring. See the Generator Set Wiring Diagram in Testing And Adjusting, "Schematics And Wiring Diagrams".

    Stop.

  • NOT OK - The engine continues to crank.

    Repair: The starting motor has failed. Troubleshoot the starting motor. Refer to the Starting Motor and/or Engine Service Manuals.

    Stop.

Test Step 6. CHECK THE STARTING MOTOR CYCLING.

  1. The fuel delivery is disabled.

  1. Turn the ECS to the START position.

Expected Result:

The starting motor should cycle on and off according to setpoint P18 (cycle crank time).

Results:

  • OK - If the starting motor cycles correctly, the problem is not present. Stop.

  • NOT OK - If the starting motor remains engaged, the starting motor has failed.

    Repair: Troubleshoot the starting motor. Refer to the Starting Motor and/or Engine Service Manuals.

    Stop.

Caterpillar Information System:

G3304 and G3306 Engines General Information (Lubrication System)
Electronic Modular Control Panel II (EMCP II) System Communication Module (Customer)
Electronic Modular Control Panel II (EMCP II) Relay Driver Module
G3406 Engine Measuring Engine Oil Pressure
G3304 and G3306 Engines Engine Oil Pressure is Low
G3304 and G3306 Engines Engine Oil Pressure is High
Electronic Modular Control Panel II (EMCP II) Fault Log Viewing OP1
3500B Marine Engines Secondary ECM Assumes Control
3126B and 3126E On-highway Engines Ignition Keyswitch Circuit and Battery Supply Circuit - Test
C-10, C-12, C-15 and C-16 Industrial Engines Air Shutoff System - Test
C-10, C-12, C-15 and C-16 Industrial Engines PTO Ramp Up/Down Switch Circuit - Test
C-9 Industrial Engine E095 Fuel Filter Restriction Warning
G3304 and G3306 Engines General Information (Cooling System)
Electronic Modular Control Panel II (EMCP II) Starting Motor Remains Engaged (for MUI 3412C, 3508, 3512, 3516 Engines)
Electronic Modular Control Panel II (EMCP II) Engine Does Not Shutdown (for EUI Engines)
Electronic Modular Control Panel II (EMCP II) Engine Does Not Shutdown (for MUI 3306B, 3406C Engines)
Electronic Modular Control Panel II (EMCP II) Engine Does Not Shutdown (for MUI 3412C, 3508,3512, 3516 Engines)
Electronic Modular Control Panel II (EMCP II) AC Offset Adjustment OP10
Electronic Modular Control Panel II (EMCP II) Engine Does Not Shutdown (for PEEC Engines)
Electronic Modular Control Panel II (EMCP II) GSC Operation Is Erratic
Electronic Modular Control Panel II (EMCP II) Display of Voltage or Current Is Zero
Electronic Modular Control Panel II (EMCP II) Normal Mode
Electronic Modular Control Panel II (EMCP II) Fault Log Clearing OP4
G3406 Engine Air Inlet and Exhaust System Components
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.