Oil Mist Detectors Caterpillar


Number 9 LED is Blinking - Troubleshoot

Usage:

3616 1FN
This condition indicates that the temperature of the electronic module is less than 0 °C (32 °F).

Indication of the Condition




Illustration 1g00738119

  • The red number 9 LED is flashing.

  • No other LED is illuminated.

Probable Causes

  • The ventilation in the engine compartment is blowing cold air onto the detector.

Recommended Repairs

  1. Direct the air from the ventilation away from the detector.

  1. After the ventilation is redirected, press the "RESET" button.

    Expected Result

    The number 9 LED is no longer flashing. The detector is operating normally.

    Results

    OK - The detector is operating normally.

    Not OK - Reset the system again. Troubleshoot any active faults.