Removal Procedure
Start By:
- Release the hydraulic system pressure. Refer to Disassembly and Assembly, "Hydraulic System Pressure - Release".
Note: Put identification marks on all hoses, on all hose assemblies, on all wires, and on all tube assemblies for installation purposes. Plug all hose assemblies and all tube assemblies. This helps to prevent fluid loss, and this helps to keep contaminants from entering the system.
NOTICE |
---|
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to Special Publication, NENG2500, "Caterpillar Tools and Shop Products Guide" for tools and supplies suitable to collect and contain fluids on Caterpillar products. Dispose of all fluids according to local regulations and mandates. |
NOTICE |
---|
Keep all parts clean from contaminants. Contamination of the hydraulic system with foreign material will reduce the service life of the hydraulic system components. To prevent contaminants from entering the hydraulic system, always plug or cap the lines, fittings, or hoses as they are disconnected. Cover any disassembled components and clean them properly before assembly. Clean the hydraulic system properly after any major component exchange or especially after a component failure, to remove any contamination. |
- Drain the oil from the hydraulic tank into a suitable container for storage or disposal. Refer to Operation and Maintenance Manual, "Hydraulic System Oil - Change" for the proper draining procedure.
- Remove cover assembly (1) .
Illustration 1 | g01172650 |
- Disconnect hoses (2) .
Illustration 2 | g01172651 |
- Remove bolts (3). Repeat for the opposite side.
- Remove hydraulic oil cooler (4) .
Illustration 3 | g01172653 |
Installation Procedure
NOTICE |
---|
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to Special Publication, NENG2500, "Caterpillar Tools and Shop Products Guide" for tools and supplies suitable to collect and contain fluids on Caterpillar products. Dispose of all fluids according to local regulations and mandates. |
NOTICE |
---|
Keep all parts clean from contaminants. Contamination of the hydraulic system with foreign material will reduce the service life of the hydraulic system components. To prevent contaminants from entering the hydraulic system, always plug or cap the lines, fittings, or hoses as they are disconnected. Cover any disassembled components and clean them properly before assembly. Clean the hydraulic system properly after any major component exchange or especially after a component failure, to remove any contamination. |
- Position hydraulic oil cooler (4) .
Illustration 4 | g01172662 |
- Install bolts (3). Repeat for the opposite side.
- Connect hoses (2) .
- Install cover assembly (1) .
Illustration 5 | g01172650 |
- Fill the hydraulic tank. Refer to Operation and Maintenance Manual, "Capacities (Refill)" for the capacity of the hydraulic tank. Refer to Operation and Maintenance Manual, "Hydraulic System Oil - Change" for the proper filling procedure.