CAN Data Link - Test

Usage:

CS54B 505

Machine ECM

The following is a list of diagnostic codes (SPN) that are associated with the CAN data link of the machine.

Table 1
Machine ECM (MID 39) 
SPN-FMI  Code Description  System Response 
639-8  J1939 Network #1: Abnormal Frequency, Pulse Width, or Period  Communication lost between Main ECM and Engine ECM
Display will show "MID 40" to report fault since the Main ECM cannot communicate
Disable Propel, Vibe
Fault Level - 3 
639-9  J1939 Network #1: Abnormal update rate  Communication lost between Main ECM and Display
Display will show "MID 40" to report fault since the Main ECM cannot communicate
Not Latched, Not Logged.
Fault Level - 3 
1231-9  J1939 Network #2: Abnormal update rate  Communication lost between Main ECM and Compaction ECM
Disable CMV/MDP Gauge Values
Fault Level - 1 
2661-9  Joystick 1 Y-Axis Position: Abnormal update rate  Disable Propel
Fault Level - 1 
2661-12  Joystick 1 Y-Axis Position: Bad device or component  Disable Propel
Fault Level -1 
2808-9  Keypad: Abnormal update rate  Loss of Communication at Startup: Use fault states and stop communication with keypad.
Fault Level - 1 
Loss of Communication After Startup: Use current states and stop communication with keypad.
Fault Level - 1
2808-12  Keypad: Failure  Faulty button at Startup: Use fault states and stop communication with keypad.
Fault Level - 1 
Faulty button After Startup: Use current states and stop communication with keypad.
Fault Level -1

Each CAN data link circuit is an input and output of select electronic control modules. The data link is designed to carry communications between the electronic control modules. The data link consists of internal control circuits and the connecting harness wiring.

Possible causes for an FMI 8 or FMI 9 diagnostic codes are:

  • The wrong software is installed on an ECM.

  • The ECM is communicating intermittently.

  • Terminating resistors on the J1939 data link are missing or have failed.

  • An open or a poor connection in the data link circuit.

  • Short in the data link circuit.

  • An ECM or smart device is not powering up or powering down properly.

  • Lack of key switch input to an ECM or smart device (where applicable).

  • The energize circuit for the MSS Key Reader may have failed.

  • Electronic noise from other electric circuits introduced into the data link.

  • One of the ECMs or smart devices has failed. This condition is unlikely.

Note: A loss of power to any ECM on the data link can cause the ECM to activate this diagnostic code combination. Ensure that the ECMs identified by this diagnostic code are powered up before proceeding with this procedure.

The FMI 09 means that the ECM has lost all communication with another control module.

The diagnostic code combination is caused by abnormal communications between the ECM and a specific ECM module via the data link. The update rate is not correct.



Illustration 1g06236233
CAN Data Link connections

The diagram above is a simplified schematic of the System Voltage Machine ECM connections. The schematic is electrically correct. However, not all the possible harness connectors are shown.

For the full Electrical Schematic of the Soil Compactors in this manual, refer to the Electrical Schematic, UENR6390.

Diagnostic Trouble Code Procedure

Note: Prior to beginning this procedure, inspect the harness connectors that are involved in this circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, secure, and in good condition. Check the wiring for pinch points or abrasions. Look for and repair areas that indicate wires are exposed. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing a troubleshooting procedure.

Table 2
FMI 8 or FMI 9 Troubleshooting 
Troubleshooting Test Steps  Values  Results 
1. Verify The Hardware And The Software Part Numbers(1)

A. Verify that the following information is correct:

-The part number of the flash software for the ECM is correct.
-The part number of the ECM is correct.
-The part numbers of the sensors are correct. 

All of the part numbers are correct 
OK - All of the part numbers are correct

Proceed to Test Step 2.

NOT OK - All of the part numbers are not correct

Repair: The ECM or the sensors have the wrong part number or incorrect flash software is installed. Flash the correct software or replace the incorrect ECM or the sensor with a module that has the correct part number. Refer to the Troubleshooting, "ECM - Flash Program" section for additional information

Proceed to Test Step 9. 
2. Inspect The Harness Connections

A. Turn key start switch and disconnect switch OFF.

B. Inspect all harness connections related to the CAN data link. Make sure that the connectors are clean and tight.

C. Check the connectors for proper mating. Ensure that all the seals are present and in place.

D. Check the harness for signs of damage or abrasion.

E. Check the wires at the connector. Ensure that the wires are secured tightly into the connector. Take care not to pull the wire out of the connector.

F. Check the exposed wires at the connectors for nicks or signs of abrasion.

G. Check for moisture inside the connector. 

The machine harness connectors are tight and free of corrosion. 
OK - The machine harness connectors are tight and free of corrosion.

Proceed to Test Step 4.

NOT OK - The machine harness connectors are in need of repair.

Repair: Repair or replace the machine harness.

Proceed to Test Step 9. 
3. Check The Voltage Of The Data Link

A. Turn the key start switch and the disconnect switch to the ON position.

B. Connect Cat® Electronic Technician (Cat ET) Service Tool and verify which ECMs have logged communication diagnostics. At each ECM or device that is not communicating, use an electrical spoon to measure the voltage. One at a time, measure the voltage of the CAN data link wires to frame ground. 

The reading is 0.5V to 4.5V on each wire. 
OK - The voltages of the wires for the data links are correct.

Proceed to Test Step 6.

NOT OK - The voltage is greater than 4.5 V.

Proceed to Test Step 7.

NOT OK - The voltage is less than 0.5 V.

Proceed to Test Step 4. 
4. Check For Short To Ground In the Data Link

A. The key start switch and disconnect switch remain OFF.

B. Disconnect the machine harness connectors from all electronic control modules that use the suspect CAN data link.

C. At the machine harness for the Machine ECM, measure the resistance between frame ground and the positive CAN connector contact of the circuit.

D. At the machine harness for the Machine ECM, measure the resistance between frame ground and the negative CAN connector contact of the circuit. 

The reading is greater than 5K Ω. 
OK - The harness circuit resistance is correct.

Proceed to Test Step 5.

NOT OK - A reading is less than 5 Ω. The machine harness has failed.

Repair: There is a short between frame ground and the contacts of the CAN data link circuit in the machine harness. Repair or replace the machine harness.

Note: A resistance that is greater than 5 Ω but less than 5K Ω would indicate a loose connection or a corroded connection in the circuit. A resistance measurement that is greater than 5K Ω would indicate an open in the circuit.

Proceed to Test Step 9. 
5. Check For A Short Between The Data Link Wires

A. The key start switch and the disconnect switch remain in the OFF position.

B. Disconnect the terminating resistors if the resistors are a part of the circuit.

C. Measure the continuity between the data link wires. 

The reading is greater than 5K Ω. 
OK - The resistance measurement is correct.

Proceed to Test Step 6.

NOT OK - The resistance measurement is not correct. The wires for the data link are shorted together.

Repair: Repair the machine harness or replace the harness.
Proceed to Test Step 9. 
6. Check The Terminating Resistors

A. The key start switch and the disconnect switch remain in the OFF position.

B. The terminating resistors remain disconnected.

C. Check the terminating resistor connectors for the following:

-Moisture
-Corrosion
-Damaged Terminals
-Loose Connections

D. Measure the resistance between terminal A and B of each terminating resistor that was removed from the CAN circuit. 

The reading is approx. 120 Ω. 
OK - Both resistance measurements are approximately 120 Ω. The terminating resistors have not failed. Reinstall the terminating resistors.

Proceed to Test Step 7.

NOT OK - One or both resistance measurements are not approximately 120 Ω. At least one of the resistors is not functioning properly.

Repair: Replace the terminating resistor or resistors that have failed. Reinstall the terminating resistor that has not failed.

Proceed to Test Step 9. 
7. Check For A Short To +Battery Circuit In The Data Link

A. The key start switch and disconnect switch are OFF.

B. All related modules remain disconnected from the machine harness.

C. At the machine harness connector for the Machine ECM, measure the resistance between the connector contact for the +Battery and the positive CAN connector contact.

D. At the machine harness connector for the Machine ECM, measure the resistance between the connector contact for the +Battery and the negative CAN connector contact. 

The reading is greater than 5K Ω. 
OK - The harness circuit resistance is correct.

Proceed to Test Step 8.

NOT OK - A reading is less than 5 Ω. The machine harness has failed.

Repair: There is a short between the +battery circuit and one of the CAN data link circuits in the machine harness. Repair or replace the machine harness.

Note: A resistance that is greater than 5 Ω but less than 5K Ω would indicate a loose connection or a corroded connection in the circuit. A resistance measurement that is greater than 5K Ω would indicate an open in the circuit.

Proceed to Test Step 9. 
8. Check The Data Link For An Open

Note: Two 120 Ω resistors should be located on the CAN Data Link. A resistance of 60 Ω should be found at any point on the data link.

A. The key start switch and disconnect switch are OFF.

B. Use an electrical spoon to connect to the back of the harness connector for each ECM that has communication issues.

C. Measure the resistance across the CAN line at each connector to find the open wire. If the resistance measurement is 60 Ω, that connector does not have an open between either terminating resistor. If the resistance measurement is 120 Ω, there is an open at that connector, between one of the terminating resistors. If the resistance is greater than 5K Ω, there is an open between that connector and both terminating resistors. If there is a measurement of 40 Ω, there is an extra terminating resistor somewhere on the line. Once the section of harness containing the open is isolated, repair or replace the machine harness. 

All resistance measurements are between 55 and 65 Ω 
OK - The resistance measurements are correct.

Proceed to Step 9.

NOT OK - At least one resistance measurement is greater than 65 Ω. If the resistance is approximately 115 to 125 Ω. There is an open in the harness.

Repair: Repair or replace the machine harness.

Proceed to Test Step 9.

NOT OK - At least one resistance measurement is less than 55 Ω.

Repair: Look for the source of the short by disconnecting the terminating resistors and check the resistance again. If the resistance is still under 55 Ω, continue disconnecting ECMs and devices from the CAN circuit until the resistance goes up.
If everything is disconnected from the CAN circuit, and the resistance still is less than 55 Ω the harness has failed.

Repair or replace the machine harness.

Proceed to Test Step 9. 
9. Check If The Diagnostic Code Remains

A. Reconnect all harness connectors. Return machine to normal operating condition.

B. Turn the key start switch and the disconnect switch ON.

C. Clear all diagnostic codes.

D. Operate the machine.

E. Stop the machine and engage the safety lock lever.

F. Check if the diagnostic code is active. 

The diagnostic code is no longer present. 
OK - The diagnostic code does not exist at this time. The initial diagnostic code may have been caused by poor electrical connection or short at one of the harness connections. Resume machine operation.

STOP.

NOT OK - The diagnostic trouble code has not been corrected. If the diagnostic code has not been corrected after performing the procedure a second time, the ECM may require replacement.

Prior to replacing the ECM, always contact the Technical Communicator at your dealership for possible consultation with Caterpillar. This consultation may effect repair time.

Follow the steps in Troubleshooting, "ECM - Replace" if the ECM needs to be replaced.

STOP. 
(1) Consult your Caterpillar Authorized Dealer for the correct part numbers of the flash software.

Caterpillar Information System:

A Procedure to Improve the ATAAC Tubes on Certain 797 and 797B Off-Highway Trucks is Available {1071} A Procedure to Improve the ATAAC Tubes on Certain 797 and 797B Off-Highway Trucks is Available {1071}
Procedure to Improve the ATAAC Tubes on Certain 797 and 797B Off-Highway Trucks {1071} Procedure to Improve the ATAAC Tubes on Certain 797 and 797B Off-Highway Trucks {1071}
CB13, CB15 and CB16 Asphalt Compactor Machine Systems Relief Valve (Main, Vibratory) - Test and Adjust
CB13, CB15 and CB16 Asphalt Compactor Propel Systems Relief Valve (Charge) - Test and Adjust
MP318, MP324, MP332, MP345 and and MP365 Multi-Processors and Jaws Gear and Bearing - Remove and Install
MD6200 Rotary Drill Water Injection System Pump - Check - If Equipped
Retrofitting Hydraulic Hose Clamping On D2 Series Loaders {5057} Retrofitting Hydraulic Hose Clamping On D2 Series Loaders {5057}
Procedures are Now Available to Rework Soot Sensor, Single Stage Precleaner, and Dual Stage Precleaner on Certain 815K Soil Compactors and 816K Landfill Compactors {1051, 1054, 1055, 108F, 108K, 1335, 1400, 1408} Procedures are Now Available to Rework Soot Sensor, Single Stage Precleaner, and Dual Stage Precleaner on Certain 815K Soil Compactors and 816K Landfill Compactors {1051, 1054, 1055, 108F, 108K, 1335, 1400, 1408}
MD6200 Rotary Drill Engine and Machine Warm-Up
PM620, PM622, PM820 and PM822 and PM825 Cold Planer Machine Systems Water Spray Lines
Brake Pedal Stop Bolt May Become Loose on Certain F2-Series Backhoe Loaders {4251} Brake Pedal Stop Bolt May Become Loose on Certain F2-Series Backhoe Loaders {4251}
PM620, PM622, PM820 and PM822 and PM825 Cold Planer Machine Systems Water Spray Lines
CS54B, CP54B and CS64B Vibratory Soil Compactors Machine Electronic Control System Speed Sensor (Dual Signal) - Test
CS54B, CP54B and CS64B Vibratory Soil Compactors Machine Electronic Control System Speed Sensor - Test
New High Strength Bolts Now Used on the Spindle to Brake Housing Joint and the Brake Housing to Brake Anchor Joint on R2900, R2900G, and R3000H Load Haul Dump Machines {4001, 4251} New High Strength Bolts Now Used on the Spindle to Brake Housing Joint and the Brake Housing to Brake Anchor Joint on R2900, R2900G, and R3000H Load Haul Dump Machines {4001, 4251}
PM620, PM622, PM820 and PM822 and PM825 Cold Planer Machine Systems Swing Cylinder Lines
Cat® Product Link Elite (PLE601) Network Managers are Not Communicating with Allen Bradley Panels After Firmware Update {0115, 449C} Cat® Product Link Elite (PLE601) Network Managers are Not Communicating with Allen Bradley Panels After Firmware Update {0115, 449C}
PM620, PM622, PM820 and PM822 and PM825 Cold Planer Machine Systems Electronic Control Module
PM620, PM622, PM820 and PM822 and PM825 Cold Planer Machine Systems Frame
PM620, PM622, PM820 and PM822 and PM825 Cold Planer Machine Systems Pump Lines - Auxiliary
Improved Fastening Method Is Now Used to Secure the Truck Body Group Mounting Pin Assembly on Certain 700 C-Series Articulated Trucks {7250, 7258} Improved Fastening Method Is Now Used to Secure the Truck Body Group Mounting Pin Assembly on Certain 700 C-Series Articulated Trucks {7250, 7258}
PM620, PM622, PM820 and PM822 and PM825 Cold Planer Machine Systems Return Lines
New Digital Voltage Regulator (DVR) Is Now Available {1410, 7620} New Digital Voltage Regulator (DVR) Is Now Available {1410, 7620}
PM620, PM622, PM820 and PM822 and PM825 Cold Planer Machine Systems Rotor
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.