Illustration 1 | g01072472 |
IQAN module (1) Yellow or Red Status LED (2) Green Power LED |
There are two indicators on the IQAN XA2 module. The green power LED (2) indicates that the module has power. The yellow or red status LED (1) indicates the status of the module. If the status LED is flashing yellow, the module detects normal status. If the status LED is flashing red, the module detects an error.
When an error is detected by one of the modules, an error message automatically appears on the IQAN Master Display (MD3).
ReferenceFor more information on the diagnostic functions of the IQAN Monitoring and Control System and on the specific descriptions of error messages, refer to the Service Manual module for Troubleshooting, "Diagnostic Capabilities".
IQAN Master Display
Failure Modes for CAN Interface
Failure Modes for CAN Interface     | ||
---|---|---|
Failure Mode     | Effect     | |
1     | CAN-H to -BAT     | No CAN communication. All output turned off.     |
2     | CAN-L to -BAT     | No CAN communication. All output turned off.     |
3     | CAN-H to +BAT     | No CAN communication. All output turned off.     |
4     | CAN-L to +BAT     | No CAN communication. All output turned off.     |
5     | CAN-L open circuit     | No CAN communication. All output turned off.     |
6     | CAN-H open circuit     | No CAN communication. All output turned off.     |
7     | CAN-L to CAN-H     | No CAN communication. All output turned off.     |
8     | CAN-termination failure, termination on     | No effect.     |
9     | CAN-termination failure, termination off     | Dependent on CAN size and number of CAN nodes.     |
Failure Modes for Reference Voltage
Failure Modes for Reference Voltage     | ||
---|---|---|
Failure Mode     | Effect     | |
1     | +VREF Open     | VIN out of range and will create a VIN error. VIN is a predefined error value.     |
2     | -VREF Open     | VIN out of range and will create a VIN error. VIN is a predefined error value.     |
3     | +VREF shorted to -VREF     | VREF error. VIN out of range and will create a VIN error. VIN is a predefined error value.     |
4     | +VREF shorted to +BAT     | VREF error. VIN out of range and will create a VIN error. VIN is a predefined error value.     |
5     | +VREF shorted to -BAT     | VREF error. VIN out of range and will create a VIN error. VIN is a predefined error value.     |
6     | -VREF shorted to +BAT     | External fuse on +BAT will blow (if less than 7.5 A).     |
7     | -VREF shorted to -BAT     | Not detected.     |
Failure Modes for VIN
Failure Modes for VIN     | ||
---|---|---|
Failure Mode     | Effect     | |
1     | VIN Open     | VIN out of range and will create a VIN error. VIN is a predefined error value. (1)     |
2     | VIN shorted to +BAT     | VIN out of range and will create a VIN error. VIN is a predefined error value. (1)     |
3     | VIN shorted to -BAT     | VIN out of range and will create a VIN error. VIN is a predefined error value. (1)     |
( 1 ) | Measure is controlled by CAN Master and application as a result from the CAN error message. Outputs are controlled by CAN master unit and are delayed a maximum of two bus cycles. |
Failure Modes for DIN
Failure Modes for DIN     | ||
---|---|---|
Failure Mode     | Effect     | |
1     | DIN Open     | No effect on module, not detected.     |
2     | DIN shorted to +BAT     | No effect on module, not detected.     |
3     | DIN shorted to -BAT     | No effect on module, not detected.     |
Failure Modes for FIN
Failure Modes for FIN     | ||
---|---|---|
Failure Mode     | Effect     | |
1     | FIN Open     | No effect on module, not detected.     |
2     | FIN shorted to +BAT     | No effect on module, not detected.     |
3     | FIN shorted to -BAT     | No effect on module, not detected.     |
Failure Modes in Current Mode
Failure Modes in Current Mode     | ||
---|---|---|
Failure Mode     | Effect     | |
1     | COUT Open     | COUT error, output turned off.     |
2     | RET (active) Open     | COUT error, output turned off.     |
3     | RET (passive) Open     | Not detected, will not influence function.     |
4     | COUT shorted to RET (active)     | COUT error, output turned off.     |
5     | COUT shorted to RET (passive)     | Not detected, will not influence function.     |
6     | COUT shorted to +BAT     | COUT error, output turned off.     |
7     | COUT shorted to -BAT     | COUT error, output turned off.     |
8     | RET (active) shorted to +BAT     | COUT error, output turned off.     |
9     | RET (active) shorted to -BAT     | COUT error, output turned off.     |
10     | RET (passive) shorted to +BAT     | Not detected, will not influence function.     |
11     | RET (passive) shorted to -BAT     | COUT error, output turned off.     |
12     | COUT shorted to 2:nd COUT (passive)     | Not detected, will not influence function.     |
13     | COUT shorted to 2:nd RET (active)     | COUT error, output turned off.     |
14     | COUT shorted to 2:nd RET (passive)     | Not detected, will not influence function.     |
15     | RET shorted to 2:nd RET (active)     | COUT error, output turned off.     |
16     | RET shorted to 2:nd RET (passive)     | Not detected, will not influence function.     |
17     | Insufficient voltage     | COUT error, output turned off.     |
IQAN-XA2
Failure Modes for Reference Voltage
Failure Modes for Reference Voltage     | ||
---|---|---|
Failure Mode     | Effect     | |
1     | +VREF Open     | VIN out of range and will create a VIN error. VIN is a predefined error value. (1)     |
2     | -VREF Open     | VIN out of range and will create a VIN error. VIN is a predefined error value. (1)     |
3     | +VREF shorted to -VREF     | VIN out of range and will create a VIN error. VIN is a predefined error value. (1)     |
4     | +VREF shorted to +BAT     | VIN out of range and will create a VIN error. VIN is a predefined error value. (1)     |
5     | +VREF shorted to -BAT     | VIN out of range and will create a VIN error. VIN is a predefined error value. (1)     |
6     | -VREF shorted to +BAT     | External fuse on +BAT will blow (if less than 7.5 A).     |
7     | -VREF shorted to -BAT     | Not detected.     |
( 1 ) | Measure is controlled by CAN master and application as a result from the CAN error message. Outputs are controlled by CAN master unit and are delayed maximum two bus cycles. |
Failure Modes for CAN Interface
Failure Modes for CAN Interface     | ||
---|---|---|
Failure Mode     | Effect     | |
1     | CAN-H to -BAT     | No CAN communication. All output turned off.     |
2     | CAN-L to -BAT     | No CAN communication. All output turned off.     |
3     | CAN-H to +BAT     | No CAN communication. All output turned off.     |
4     | CAN-L to +BAT     | No CAN communication. All output turned off.     |
5     | CAN-L open circuit     | No CAN communication. All output turned off.     |
6     | CAN-H open circuit     | No CAN communication. All output turned off.     |
7     | CAN-L to CAN-H     | No CAN communication. All output turned off.     |
8     | CAN-termination failure, termination on     | No effect.     |
9     | CAN-termination failure, termination off     | Dependent on CAN size and number of CAN nodes.     |
Failure Modes for VIN
Failure Modes for VIN     | ||
---|---|---|
Failure Mode     | Effect     | |
1     | VIN Open     | VIN out of range and will create a VIN error. VIN is a predefined error value. (1)     |
2     | VIN shorted to +BAT     | VIN out of range and will create a VIN error. VIN is a predefined error value. (1)     |
3     | VIN shorted to -BAT     | VIN out of range and will create a VIN error. VIN is a predefined error value. (1)     |
( 1 ) | Measure is controlled by CAN master and application as a result from the CAN error message. Outputs are controlled by CAN master unit and are delayed maximum two bus cycles. |
Failure Modes for DIN
Failure Modes for DIN     | ||
---|---|---|
Failure Mode     | Effect     | |
1     | DIN Open     | No effect on module, not detected.     |
2     | DIN shorted to +BAT     | No effect on module, not detected.     |
3     | DIN shorted to -BAT     | No effect on module, not detected.     |
Failure Modes for FIN
Failure Modes for FIN     | ||
---|---|---|
Failure Mode     | Effect     | |
1     | FIN Open     | No effect on module, not detected.     |
2     | FIN shorted to +BAT     | No effect on module, not detected.     |
3     | FIN shorted to -BAT     | No effect on module, not detected.     |
Failure Modes in Current Mode
Failure Modes in Current Mode     | ||
---|---|---|
Failure Mode     | Effect (1)     | |
1     | COUT Open     | COUT error, output turned off.     |
2     | RET (active) Open     | COUT error, output turned off.     |
3     | RET (passive) Open     | Not detected, will not influence function.     |
4     | COUT shorted to RET (active)     | COUT error, output turned off. (2)     |
5     | COUT shorted to RET (passive)     | Not detected, will not influence function.     |
6     | COUT shorted to +BAT     | COUT error, output turned off.     |
7     | COUT shorted to -BAT     | COUT error, output turned off. (2)     |
8     | RET (active) shorted to +BAT     | COUT error, output turned off. (2)     |
9     | RET (active) shorted to -BAT     | COUT error, output turned off.     |
10     | RET (passive) shorted to +BAT     | Not detected, will not influence function.     |
11     | RET (passive) shorted to -BAT     | COUT error, output turned off.     |
12     | COUT shorted to 2:nd COUT (passive)     | Not detected, will not influence function.     |
13     | COUT shorted to 2:nd RET (active)     | COUT error, output turned off. (2)     |
14     | COUT shorted to 2:nd RET (passive)     | Not detected, will not influence function.     |
15     | RET shorted to 2:nd RET (active)     | COUT error, output turned off.     |
16     | RET shorted to 2:nd RET (passive)     | Not detected, will not influence function.     |
17     | Insufficient voltage     | COUT error, output turned off.     |
( 1 ) | Outputs are controlled by CAN master and therefore delayed by maximum two bus cycles. If local error handling is enabled, the output will turn off locally without delay. |
( 2 ) | Turned off by integrated protection functions in IC. |
Status Values
Status is used to indicate warnings, errors, or other info. The status is an integer in the range 0 - 255, which is divided into four ranges. Some status changes are shown as on-screen messages or LED codes on the master, and some are even logged in the system log.
Status Values     | |
---|---|
Integer     | Status     |
0-63     | Information     |
64-127     | OK     |
128-191     | Warning     |
192-255     | Error     |
The "Msg" column states whether a system message dialog box is displayed or not. The "Log " column states whether a record is created in the system log or not.
Status Description Msg Log
Status Description Msg Log     | ||||
---|---|---|---|---|
n     | Status     | Description     | Msg     | Log     |
0     | Disabled     | Component disabled. Not evaluated.     |     |     |
1     | Not evaluated     | Not evaluated. Not evaluated due to lazy evaluation.     |     |     |
64     | OK     | Status OK.     |     |     |
128     | High temperature     | Module internal temperature (only IQAN modules).     | X     | X     |
129     | Low supply voltage     | Module internal temperature (only IQAN modules).     | X     | X     |
130     | High supply voltage     | Module internal temperature (only IQAN modules).     | X     | X     |
131     | Date and time not set     | Applies to master module only.     | X     | X     |
132     | Start block     | Lever not in zero position at power-up.     | X     | X     |
133     | Low Alarm     | Value below low alarm level on input channel.     | X     | X     |
134     | High Alarm     | Value over high alarm level on input channel.     | X     | X     |
135     | Saturated     | Not able to output commanded current. Current is 50-100% of commanded.     |     | X     |
137     | Checksum error     | Checksum calculation error for adjustable/stored value.     |     | X     |
192     | Low error     | Value below low alarm level on input channel.     | X     | X     |
193     | High error     | Value over high error level on input channel.     | X     | X     |
194     | Overload     | Output overloaded.     | X     | X     |
195     | Open load     | Output is disconnected. Current is less than 50% of commanded.     | X     | X     |
196     | Division by zero     | Math calculation.     |     | X     |
197     | Calculation overflow     | Math calculation.     |     | X     |
198     | Negative square root     | Math calculation.     |     | X     |
199     | Invalid argument     | Math calculation.     |     | X     |
200     | J1939 error     | J1939 error detected at parameter input channel (PIN).     | X     | X     |
201     | J1939 not available     | Parameter (PIN) not available in J1939 parameter group (PGIN).     | X     | X     |
202     | Timeout     | Timeout detected on parameter group input (PGIN) or generic frame input (GFIN).     | X     | X     |
203     | No contact     | No contact with expansion module. Applies to all modules.     | X     | X     |
204     | Multiple address     | Two or more IQAN modules with same address detected.     | X     | X     |
205     | VREF error     | VREF error detected on IQAN module.     | X     | X     |
206     | Internal error     | Internal IQAN module error.     | X     | X     |
207     | Critical error     | Critical IQAN module error.     | X     | X     |
208     | Pin conflict     | Invalid channel type connected to module pin.     |     |     |
209     | CAN bus error     | CAN bus does not work.     |     |     |
210     | Address error     | Invalid address tag on master module.     | X     | X     |
211     | Out of range     | A parameter or channel value is out of range.     |     | X     |
212     | Input error     | Error detected on input channel (used by AAC, DDC, and ADC channels).     | X     | X     |
213     | Diff check error     | Input channels not equal (used by AAC, DDC, and ADC channels).     | X     | X     |