MID 039 - CID 1704 - FMI 03

Usage:

D6K LGP DHA
Conditions Which Generate This Code:


Illustration 1g01327228

Schematic of the Left Drive Pump Referse Control Solenoid

This diagnostic code is associated with the implement pilot supply solenoid. The FMI 03 means that the ECM has detected that the voltage of the solenoid circuit is above normal or that the ECM has detected voltage in the circuit when no voltage should be present.

Conditions that could causes this diagnostic code to be activated are:

  • The energize circuit of the solenoid is shorted to another voltage source.

  • The ECM has failed. This is unlikely.

Note: Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, secure and in good condition. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing this procedure.

Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected.

System Response:

A Level 2 warning will be generated. Functionality is lost in forward direction. Motion in reverse direction is allowed with level 3 active event.

Test Step 1. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT

  1. Turn the disconnect switch and the key start switch to the OFF position.

  1. Disconnect the machine harness connector from the solenoid. Disconnect the machine harness connectors J1 and J2 from the ECM.

  1. At the machine harness ECM connectors, measure the resistance from contact J1-49 (wire K943-OR) to all of the other contacts that are used in the J1 and J2 connectors for the ECM.

Expected Result:

Each resistance measurement is greater than 5000 ohms.

Results:

  • YES - Each resistance measurement is greater than 5000 ohms. The resistance measurement does not indicate a short in the machine harness. Proceed to Test Step 2.

  • NO - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness.

    Repair: The short is between wire K943-OR and the circuit that has a low resistance measurement.For information on testing for short circuits and finding short circuits, refer to Testing and Adjusting, "Wiring Harness (Short Circuit) - Test". Repair the machine harness or replace machine harness.

    STOP

Test Step 2. CHECK THE OPERATION OF THE ECM

The disconnect switch and the key start switch remain in the OFF position. The machine harness connectors for the solenoid and the ECM remain disconnected.

  1. At the machine harness connector J1 for the ECM, use a 151-6320 Removal Tool to remove the solenoid energize wire K943-OR and socket at contact J1-49 from the harness connector.

  1. Reconnect the machine harness J1 and J2 connectors to the ECM.

  1. Turn the disconnect switch and the key start switch to the ON position.

  1. Observe the status of the active CID 1704 FMI 03 diagnostic code.

Expected Result:

The CID 1704 FMI 03 diagnostic code is no longer active. A CID 0358 FMI 05 diagnostic code is now active.

Results:

  • YES - The CID 1704 FMI 03 diagnostic code is no longer active. A CID 1704 FMI 05 diagnostic code has been activated after the solenoid energize circuit was disconnected. The ECM has responded correctly to the open circuit condition in the solenoid circuit.

    Reinstall the disconnected solenoid energize wire back into the correct space in the ECM connector before proceeding to the next test step.

    Proceed to Test Step 3.

  • NO - The CID 1704 FMI 03 diagnostic code remains active. The status of the active diagnostic code did not change when the solenoid energize wire was disconnected from the ECM.

    Repair: The ECM has not responded correctly to the open condition in the solenoid circuit. The operation of the ECM is not correct.Prior to replacing an ECM, always contact your dealership's Technical Communicator for possible consultation with Caterpillar. This consultation may greatly reduce repair time. If the ECM must be replaced, refer to Testing and Adjusting, "Electronic Control Module (ECM) - Replace".

    STOP

Test Step 3. CHECK THE STATUS OF THE DIAGNOSTIC CODE

  1. Inspect the harness connectors and clean the contacts of the harness connectors and check the wires for damage to the insulation that is caused by excessive heat, battery acid, or chafing.

  1. Perform a 45 N (10 lb) pull test on each of the wires that are associated with the circuit.

  1. Reconnect all harness connectors. Make sure that the connectors are fully seated and the clips for each connector are completely fastened.

  1. Turn the disconnect switch and the key start switch to the ON position.

  1. Operate the machine.

  1. Determine if the CID 1704 FMI 03 diagnostic code is active.

Expected Result:

The CID CID 1704 FMI 03 diagnostic code is active.

Results:

  • YES - The CID 1704 FMI 03 diagnostic code remains active.

    Repair: Check the circuit again. Use the Caterpillar Electronic Technician (ET) service tool, if available, in order to perform a "Wiggle Test" on the machine wiring harness. The wiggle test can detect momentary or intermittent shorts or opens in the machine wiring harness.If the problem remains, the ECM may have failed. This is unlikely because the ECM detected the open circuit condition in the solenoid circuit and activated the FMI 05 diagnostic code when the solenoid energize wire was disconnected.Verify that all possible causes of the diagnostic code have been investigated. Exit this procedure and perform this procedure again.Prior to replacing an ECM, always contact your dealership's Technical Communicator for possible consultation with Caterpillar. This consultation may greatly reduce repair time. If the cause of the diagnostic code is not found and the ECM must be replaced, refer to Testing and Adjusting, "Electronic Control Module (ECM) - Replace".

    STOP

  • NO - The CID 1704 FMI 03 code is not active. The problem does not exist at this time.

    Repair: The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.

    STOP

Caterpillar Information System:

814F Series 2 Wheel Dozer, 815F Series 2 Soil Compactor and 816F Series 2 Landfill Compactor Braking System Foot Brake Control
AS3251C Asphalt Paver Solenoid Valve (Extender Extend) - Install
AS3251C Asphalt Paver Solenoid Valve (Extender Extend) - Remove
PL61 Pipelayer and D6K Track-Type Tractor Diagnostic Capabilities
450E Backhoe Loader Axles, Differential and Brakes Wheel and Tire (Front)
120M, 12M, 140M, 14M, 160M and 16M Motor Graders Power Train Electronic Control System MID 027 - CID 1961 - FMI 04
793D Off-Highway Truck/Tractor Steering Link - Assemble
C11 and C13 Engines and 14M and 16M Motor Graders Throttle Lock - Test
793D Off-Highway Truck/Tractor Steering Link - Disassemble
793D Off-Highway Truck/Tractor Steering Link - Install
793D Off-Highway Truck/Tractor Steering Link - Remove
AS3251C Asphalt Paver Power Adjuster Motor Group (Sloper) - Install
PL61 Pipelayer and D6K Track-Type Tractor MID 039 - CID 1704 - FMI 05
777G Off-Highway Truck Engine Supplement Disconnect Switch (Battery) - Remove and Install
AS3251C Asphalt Paver Height Adjuster Jack (Extender) - Remove and Install
C175-16 and C175-20 Engines for Off-Highway Trucks Vibration Damper
914G2 and IT14G2 Compact Wheel Loaders Lubricant Viscosities - Fluids Recommendations
120M, 12M, 140M, 14M, 160M and 16M Motor Graders Power Train Electronic Control System MID 027 - CID 1674 - FMI 05
24M Motor Grader Power Train Electronic Control System MID 027 - CID 1674 - FMI 06
PL61 Pipelayer and D6K Track-Type Tractor MID 039 - CID 1704 - FMI 06
The Response of the Implements Are Slow Due to the Hydraulic Pump{5070} The Response of the Implements Are Slow Due to the Hydraulic Pump{5070}
2006/10/16 Scrapers for the Tracks on the Floor for the Ejector Body Can Be Made {6203}
2006/10/02 A Discharge Chute for Debris in the Ejector Body Is Used {6203}
AS3251C Asphalt Paver Screed Plate (Main) - Remove and Install
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.