Usage:
Start By:
a. remove expansion tank and heat exchanger
FLUID SPILLAGE CONTAINMENT
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the machine. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to "TOOLS AND SHOP PRODUCT GUIDE, NENG2500", for tools and supplies suitable to collect and contain fluids in Caterpillar machines. Dispose fluids according to local regulations and mandates.
1. Remove water temperature regulators (1).
NOTICE |
---|
Be sure the water temperature regulators are installed correctly. If the regulators are not installed correctly, engine overheating will result. |
NOTE: For installation of the water temperature regulators, reverse the removal step.
NOTE: For more detailed information regarding the water temperature regulators, see the topic "Water Temperature Regulators" in the Specifications Manual.
End By:
a. install expansion tank and heat exchanger