Disassembly Procedure
Start By:
- Remove the vibratory and steering pump. Refer to Disassembly and Assembly, "Gear Pump (Steering and Vibratory) - Remove".
Note: Cleanliness is an important factor. Before you begin the disassembly procedure, the exterior of the components should be thoroughly cleaned. This will help to prevent dirt from entering the internal mechanism. Precision components can be damaged by contaminants or by dirt. Perform the disassembly procedures on a clean work surface. Keep components covered and protected at all times.
Note: In some cases, it may not be economical or it may not be practical to recondition a pump. This determination is made after disassembly and a close inspection of the pump components. Due to wear, reconditioning may not be possible. If the cost of reconditioning a pump exceeds the cost of a remanufactured pump, the pump should be replaced with a remanufactured pump instead of a reconditioned pump.
Show/hide table
|
|
|
Illustration 1 | g01025467 |
- Remove bolts (3). Remove steering pump (2) from vibratory pump (1) .
Show/hide table
|
|
|
Illustration 2 | g01025469 |
Note: Steps 2 through 5 are for the disassembly of the steering pump.
- Remove relief valve (7), gear assembly (5), and end cap (4) from housing (6). Remove the seal from the end cap.
Show/hide table
|
|
|
Illustration 3 | g01025473 |
- Remove backup ring (9) and O-ring seal (8) from relief valve (7) .
Show/hide table
|
|
|
Illustration 4 | g01025477 |
- Remove seal (10) and O-ring seal (11) from housing (6) .
Show/hide table
|
|
|
Illustration 5 | g01025480 |
- Remove gear carrier (12) for each end of the gear assembly. Remove seal retainer (13) and seal (14) .
Show/hide table
|
|
|
Illustration 6 | g01025483 |
Note: Steps 6 through 12 are for the disassembly of the vibratory pump.
- Remove bolts (15) and nuts (16) which hold the vibratory pump together. Remove mounting flange (17) from the housing.
Show/hide table
|
|
|
Illustration 7 | g01096268 |
- Remove O-ring seal (19) from mounting flange (17). Remove lip seal (18) from the mounting flange, if necessary.
Show/hide table
|
|
|
Illustration 8 | g01025487 |
- Remove seal (20), seal retainer (21), and seal (22) from the mounting flange.
Show/hide table
|
|
|
Illustration 9 | g01025488 |
- Remove wear plate (24) from housing (23) .
Show/hide table
|
|
|
Illustration 10 | g01025490 |
- Remove gear assemblies (25) from housing (23) .
Show/hide table
|
|
|
Illustration 11 | g01025495 |
- Remove wear plate (26) and housing (23) from end cover (27) .
Show/hide table
|
|
|
Illustration 12 | g01025501 |
- Remove seal (28) and seal retainer (29) from end cover (27). Remove the seal that was under the retainer.