Removal Procedure
Start By:
- Release the hydraulic system pressure. Refer to Disassembly and Assembly, "Hydraulic System Pressure - Release".
NOTICE |
---|
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to Special Publication, NENG2500, "Caterpillar Dealer Service Tool Catalog" for tools and supplies suitable to collect and contain fluids on Caterpillar products. Dispose of all fluids according to local regulations and mandates. |
Note: Put identification marks on all hoses, on all hose assemblies, on all wires, and on all tube assemblies for installation purposes. Plug all hose assemblies and all tube assemblies. This helps to prevent fluid loss, and this helps to keep contaminants from entering the system.
Note: Cleanliness is an important factor. Before the disassembly procedure, the exterior of the component should be thoroughly cleaned. This will help to prevent dirt from entering the internal mechanism.
- Open access door (1) .
Illustration 1 | g01176377 |
- Release latch (2) and position refrigerant condenser and mounting (3) forward.
Illustration 2 | g01194373 |
- Disconnect harness assemblies (4) .
Illustration 3 | g01194380 |
- Remove solenoid valves (5) and the O-ring seals.
Installation Procedure
NOTICE |
---|
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to Special Publication, NENG2500, "Caterpillar Dealer Service Tool Catalog" for tools and supplies suitable to collect and contain fluids on Caterpillar products. Dispose of all fluids according to local regulations and mandates. |
Note: Cleanliness is an important factor. Before the assembly procedure, the exterior of the component should be thoroughly cleaned. This will help to prevent dirt from entering the internal mechanism.
- Install solenoid valves (5) and the O-ring seals.
Illustration 4 | g01194380 |
- Connect harness assemblies (4) .
- Position refrigerant condenser and mounting (3) and fasten latch (2) .
Illustration 5 | g01194373 |
- Close access door (1) .
Illustration 6 | g01176377 |