SCJ and 8SC Series Alternators Caterpillar


Field Winding - Test

Usage:

D10R 3KR

Field Winding Continuity Test




Illustration 1g01065374

Rotor Assembly

(3) Slip Rings

(4) Rotor

(5) Rotor Shaft

  1. Set the multimeter to the 200 ohm resistance scale. Measure the resistance between the slip rings (3) .

  1. The resistance between the slip rings (3) should be within the following values.

    Resistance of field winding at 24 °C (75 °F)

    184-7171 Alternator Gp ... 5.29 to 5.69 Ohms
    220-4995 Alternator Gp ... 5.29 to 5.69 Ohms
    150-1935 Alternator Gp ... 6.52 to 6.88 Ohms
    215-5568 Alternator Gp ... 6.52 to 6.88 Ohms
    264-0511 Alternator Gp ... 3.19 to 3.74 Ohms

  1. Replace the rotor (4) if the measurement is incorrect.

Field Winding Ground Test

  1. Set the multimeter to the 20 M ohm resistance scale. Measure the resistance between one of the slip rings (3) and the rotor shaft (5) .

  1. The multimeter reading should be greater than 100 K Ohms (0.100 M Ohms).

  1. Replace the rotor (4) if the multimeter reading is low. Low resistance indicates undesired continuity between the field winding and the rotor shaft.

  1. Repeat steps 1 through 3 for the other slip ring (3) .
Back to top