G3408C and G3412C Engines Caterpillar


Before Starting Engine

Usage:

G3408C 3WR
Note: Certain procedures are required before an engine is started for the first time. Refer to the Special Instruction, REHS0371, "Installation and Initial Start-Up Procedure for G3300 and G3400 Engines".

Perform the required daily maintenance and other periodic maintenance before starting the engine. This can prevent major repairs at a later date. Refer to the Operation and Maintenance Manual, "Maintenance Interval Schedule" (Maintenance Section).

Walk-Around Inspection


NOTICE

For any type of leak (coolant, lube, or fuel) clean up the fluid. If leaking is observed, find the source and correct the leak. If leaking is suspected, check the fluid levels more often than recommended until the leak is found or fixed, or until the suspicion of a leak is proved to be unwarranted.


To obtain maximum service life for your engine, make a thorough inspection before starting the engine. Make a walk-around inspection of the installation. Look for items such as oil or coolant leaks, loose bolts and trash buildup. Remove any trash. Make repairs, if necessary.

  • Inspect the drive belts for cracks and wear.

  • The guards must be in the proper place. Repair damaged guards or replace missing guards.

  • Ensure that the areas around the rotating parts are clear.

Air Inlet System

------ WARNING! ------

Unburned gas in the air inlet and exhaust system may ignite when the engine is started. Personal injury and/or property damage may result.

Before starting an engine that may contain unburned gas, purge the unburned gas from the air inlet and exhaust system. Refer to the topic on purging unburned gas in the "Starting the Engine" section.


  • Ensure that the air inlet piping and the air filters are in place.

  • Ensure that all clamps and connections are secure.

  • Inspect the air cleaner service indicator (if equipped). Service the air cleaner filter element when the yellow diaphragm enters the red zone, or the red piston locks in the visible position.

  • Inspect flexible piping for cracks and leaks.

Cooling System

  • Inspect the cooling system for leaks or loose connections. Inspect the condition of all the hoses and pipes for the cooling system. Ensure that the connections are properly clamped.

  • Inspect the water pumps for evidence of leaks.

  • Check the coolant level. Add coolant, if necessary. For information on the proper coolant to use, see this Operation and Maintenance Manual, "Refill Capacities and Recommendations" (Maintenance Section).

  • For engines with separate circuit aftercooling, open the water supply.

Driven Equipment

  • Check the oil levels of the driven equipment. Perform any maintenance that is required for the driven equipment. Refer to the literature that is provided by the OEM of the driven equipment.

  • If the engine is equipped with a clutch, ensure that the clutch is disengaged.

  • For generator set engines, ensure that the main circuit breaker is open.

Electrical System

Inspect the wiring for the following conditions:

  • Loose connections

  • Wiring that is worn or frayed

Inspect the gauge panel and the control panel for good condition. Reset any shutoff or alarm components.

Fuel System

------ WARNING! ------

NEVER use a flame to check for gas leaks. Use a gas detector.

An open flame can ignite mixtures of air and fuel. This will cause explosion and/or fire which could result in severe personal injury or death.


  • Check the fuel system for leaks with a gas detector.

  • Inspect the fuel lines for loose fittings. Ensure that the fuel lines are properly clamped.

  • Ensure that the fuel is supplied to the engine at the correct pressure for the engine.

Lubrication System



Illustration 1g00760044
Oil level gauge (dipstick)
(1) "ADD" mark
(2) "FULL" mark


NOTICE

Excessive engine oil will increase oil consumption and result in excessive deposits in the combustion chamber. Do not overfill the engine with oil.


  • Check the engine crankcase oil level. Maintain the oil level between the "ADD" and "FULL" marks on the "ENGINE STOPPED" side of the oil level gauge. For information on the proper oil to use, see this Operation and Maintenance Manual, "Refill Capacities and Recommendations" (Maintenance Section).

  • Check for leaks at the following components: crankshaft seals, crankcase, oil filters, oil gallery plugs, sensors and valve cover.

  • Inspect the tubes, and the clamps on the crankcase breathers.

Starting System

Note: If the engine is equipped with a system for external support, prepare the system before starting the engine. Ensure that all of the systems for engine support are enabled. Perform all prestart checks for the control system.

Air Starting Motor

  • Drain moisture and sediment from the air tank and from any other air piping.

  • Check the oil level in the lubricator. Keep the lubricator at least half full. Add oil, if necessary. For temperatures above 0 °C (32 °F), use a nondetergent 10W oil. For temperatures below 0 °C (32 °F), use air tool oil.

  • Check the air pressure for starting. The air starting motor requires a minimum of 690 kPa (100 psi). The maximum allowable air pressure is 1030 kPa (150 psi). Open the air supply valve.

Electric Starting Motor

  • Disconnect any battery chargers that are not protected against the high current drain that is created when the electric starting motor engages.

Inspect the wiring, the electrical cables, and the battery for the following conditions:

  • Loose connections

  • Wires that are worn or frayed

  • Corrosion

Caterpillar Information System:

G3408 and G3412 Engines Engine Operation
C-10 and C-15 Petroleum Engines Ether Injection System - Test
C15 Petroleum Engine After Stopping Engine
2004/06/01 Realignment of Air System Components is Recommended. {1063}
C18 Generator set and C18 Marine Engines Heat Exchanger - Assemble - Without Fuel Cooler
C18 Generator set and C18 Marine Engines Heat Exchanger - Disassemble - With Fuel Cooler
C-10 and C-15 Petroleum Engines Engine Speed/Timing Sensor Circuit - Test
SCJ and 8SC Series Alternators Charging System
SCJ and 8SC Series Alternators Service Tools
C-12 Generator Set Engine CID 0268 FMI 02 Check Programmable Parameters
G3300 Engines Cooling System Coolant (NGEC) - Change
2004/05/01 New Water Lines Groups are Used for Venting of the Separate Circuit Aftercooler {1380}
G3408C and G3412C Engines Starting with Jump Start Cables
2004/04/01 An Unknown Diagnostic Fault Code is Displayed on the CAT Electronic Service Tool Display {1901}
G3408C and G3412C Engines Engine Oil Level - Check
C-10 and C-15 Petroleum Engines Injector Solenoid Circuit - Test
3126B Petroleum Engine Throttle Position Sensor Circuit - Test
G3520C and G3520E Engines Temperature Sensor - Thermocouple
SCJ and 8SC Series Alternators Capacitor - Test
SCJ and 8SC Series Alternators Field Winding - Test
SCJ and 8SC Series Alternators Stator - Test
3516B and 3516B High Displacement Engines for 994D and 994F Wheel Loaders Accessory Drive (Upper Left Hand)
3126B Petroleum Engine Diagnostic Flash Code Retrieval
C-15 Petroleum Engine Auxiliary Water Pump - Disassemble
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.