797 and 797B Off-Highway Truck Power Train Electronic Control System Caterpillar


MID 081 - CID 0709 - FMI 05

Usage:

797 5YW
Conditions Which Generate This Code:


Illustration 1g00568117
(1) Safety cables.


Illustration 2g00579554
Torque Converter Lockup Clutch Valve
(2) Lockup clutch solenoid valve.

The location for the lockup clutch solenoid valve is on the torque converter lockup clutch valve that is mounted to the torque converter housing.



Illustration 3g00579559
Schematic Of The Lockup Clutch Solenoid Valve

Note: The approximate coil resistance of the solenoid is 8 ohms at 20 °C (68.0 °F).

This diagnostic code is associated with the Modulating Valve (Lockup Clutch). The FMI 05 means that the ECM has determined that the current of the solenoid is below normal.

The possible causes of this diagnostic code are listed below:

  • The energize circuit of the solenoid is open.

  • The return circuit of the solenoid is open.

  • The solenoid has failed.

  • The ECM has failed. This is unlikely.

Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 0709 FMI 05 is active before performing this procedure.

Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.

------ WARNING! ------

When it is necessary to work under the machine with the body (bed) raised, attach the body (bed) retaining cables to the rear tow points. Install the rear tow point pins through the ends of the retaining cables.

Failure to properly secure the body (bed) may result in personal injury or death.


Test Step 1. CHECK THE SOLENOID.

  1. Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.

  2. Disconnect the solenoid with the active diagnostic code from the machine harness.

  3. At the machine harness connector for the solenoid, place a jumper wire from contact 1 (wire 705-PA8-PK(Pink)) to contact 2 (wire H803-PA9-BU(Blue)).

  4. Observe the status of the CID 0709 FMI 05.

Expected Result:

The CID 0709 FMI 05 remains active. The FMI has not changed and the "05" is still active.

Results:

  • YES - The diagnostic code remains active. The jumper wire does not affect the diagnostic code. Proceed to Test Step 2.

  • NO - The diagnostic is no longer active. The solenoid has failed.

    Repair: The solenoid has failed. Repeat this Test Step "CHECK THE SOLENOID" in order to verify the solenoid failure. Replace the solenoid. Verify that the new solenoid corrects the problem.

    STOP

Test Step 2. CHECK THE HARNESS FOR AN OPEN.

  1. Turn the key start switch and the disconnect switch to the OFF position.

  2. Disconnect the machine harness connector(s) from the ECM.

  3. The jumper wire that was installed in the previous Test Step remains in place.

  4. At the machine harness connector, measure the resistance from signal contact J2-60 (wire 705-AM44-PK(Pink)) to contact J2-59 (wire H803-AM54-BU(Blue)).

Expected Result:

The resistance is less than 5.0 ohms.

Results:

  • OK - The resistance is less than 5.0 ohms. The machine harness is correct. Proceed to Test Step 3.

  • NOT OK - The resistance is greater than 5000 ohms. The resistance measurement is not correct. There is an open circuit in the machine harness.

    Repair: The open is in wire 705-AM44-PK(Pink) or in wire H803-AM54-BU(Blue) of the machine harness. Repair the machine harness or replace the machine harness.

    STOP

Test Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS.

  1. Inspect the contacts of the harness connectors and clean the harness connectors.

  2. Reconnect all harness connectors.

  3. Turn the disconnect switch and the key start switch to the ON position.

  4. Operate the machine.

  5. Check the status of the CID 0709 FMI 05.

Expected Result:

The CID 0709 FMI 05 is active.

Results:

  • YES - The CID 0709 FMI 05 is active. The diagnostic code has not been corrected. The ECM may have failed.

    Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace".

    STOP

  • NO - The CID 0709 FMI 05 is not active. The diagnostic code does not exist at this time.

    Repair: The initial diagnostic code was probably caused by a poor electrical connection at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.

    STOP

Caterpillar Information System:

2002/06/24 Correction to Specifications , "Pressure Control Valve (Transmission)" {3074}
RM-350B Reclaimer Mixer Machine Electronic Control System Using Caterpillar Monitoring System to Determine Diagnostic Codes
938G Series II Wheel Loader and IT38G Series II Integrated Toolcarrier Engine Oil Level - Check
797 and 797B Off-Highway Truck Power Train Electronic Control System MID 081 - CID 0709 - FMI 03
3056E Industrial Engine Crankshaft Seals
797 and 797B Off-Highway Truck Power Train Electronic Control System MID 081 - CID 1428 - FMI 03
247 and 257 Multi Terrain Loaders Loader Frame
3056E Industrial Engine Water Temperature Regulator
797 and 797B Off-Highway Truck Power Train Electronic Control System MID 081 - CID 0673 - FMI 08
3056E Industrial Engine Engine Oil Pan
797 and 797B Off-Highway Truck Power Train Electronic Control System MID 081 - CID 1427 - FMI 06
3054E Industrial Engine Engine Oil Pressure
797 and 797B Off-Highway Truck Power Train Electronic Control System MID 081 - CID 0709 - FMI 06
120H, 12H, 135H, 140H, 143H, 160H and 163H Motor Graders Transmission Charging Pump Pressure - Test
797 and 797B Off-Highway Truck Power Train Electronic Control System MID 081 - CID 0826 - FMI 03
Instructions for Updating the CABSDos Software and Reinstalling the CABSDos Software{7610, 7620} Instructions for Updating the CABSDos Software and Reinstalling the CABSDos Software{7610, 7620}
2002/05/27 Preparation of Air Conditioner Units for Seasonal Use {7320}
797 and 797B Off-Highway Truck Power Train Electronic Control System MID 081 - CID 0826 - FMI 04
797 and 797B Off-Highway Truck Power Train Electronic Control System MID 081 - CID 0967 - FMI 02
2002/04/01 Change to Specifications Manual {1157}
Installation Procedure for Installing a Blade on 574 Forwarders{6060} Installation Procedure for Installing a Blade on 574 Forwarders{6060}
120H, 12H, 135H, 140H, 143H, 160H and 163H Motor Graders Transmission Pressures - Test
C-9 Engine for MT735, MT745, MT755, MT765, MTC735, MTC745, MTC755, and MTC765 Agricultural Tractors System Configuration Parameters
IQAN<COMP-BREAK TAGNAME=cp850>©<COMP-RESUME> Monitoring ; Control System Retrieving and Saving Parameter Files
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.