Removal Procedure
NOTICE |
---|
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the machine. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to Special Publication, NENG2500, "Caterpillar Tools and Shop Products Guide", for tools and supplies suitable to collect and contain fluids in Caterpillar machines. Dispose of all fluids according to local regulations and mandates. |
Note: Mark all lines, hoses, wires, and tubes for identification purposes. Plug all lines, hoses, and tubes in order to prevent foreign material from entering the system.
Note: Drain all fluids into a suitable container for storage or disposal.
- Remove four clamps (1). Remove two bolts (2) and remove cooler bypass valve (3) .
Illustration 1 | g00529112 |
Installation Procedure
- Install cooler bypass valve (3). Install two bolts (2) and attach four clamps (1) .
Illustration 2 | g00529112 |