Usage:
All Models
Warranty Category: Y
131-5050 DataView Group (PC not included)
Caterpillar DataView is a portable diagnostic tool that allows data, measured by sensors temporarily installed on Caterpillar products to be viewed on a Personal Computer. It allows many of the individual hand-held diagnostic tools currently in use by technicians to be replaced with a single unit. DataView also allows diagnostic data to be shared with other PC programs, such as the Caterpillar Service Information System (SIS) and the Caterpillar Electronic Technician (ET). DataView can be used with all Caterpillar products. DataView consists of a portable hardware instrument (DataView hardware) which connects to a standard PC via the parallel printer port and a Windows based software program (DataView software) that runs on the PC. The DataView software program provides setup, digital displays, graphs, and data logging of the measurements being taken. The hardware will accept up to nine standard Caterpillar sensors. A parallel port on DataView is provided for operating a printer when DataView is attached to the PC. DataView operates from an internal battery pack, but can also be powered from an external power source (110 to 220 Volts AC). Power can also be taken directly from a machine battery of 11 to 40 Volts DC or by using a vehicle 12 Volt or 24 Volt cigarette lighter.
Caterpillar PC-Based Diagnostic Tools. - A future version of DataView software will provide startup of DataView from the Tool Box Manager.
Features/Benefits
-
- * PC-based diagnostic tool. Accepts up to nine standard Caterpillar sensors for measurements on any engine or machine. Allows data to be displayed on a Personal Computer (PC).
- * Includes Data Logger using 2 Mbyte PC Memory Card for storage. Data Logger has Auto Triggering and Pre-Trigger information settings.
- * Measures pressure, temperature, blowby, position, RPM, Hz, duty cycle (PWM), hydraulic flow, and fuel flow.
- * DataView hardware unit connects to standard PC parallel (printer) port. DataView software program runs on PC using Microsoft Windows/tm/ or IBM OS/2/tm/ operating system.
- * Allows many current hand-held diagnostic tools to be replaced with a single diagnostic unit.
- * Includes digital and analog measurements, bar graphs, charts, and histograms in real time or Data Logged data.
- * DataView can provide test/diagnostic data for test facilities such as dynamometer rooms, transmission test centers, or any other application where diagnostic measurements are required.
- * Future versions of DataView software will interface with other programs such as SIS and ET.
- * Six "Analog" inputs for measuring any combination of pressure, temperature, blowby, and position.
- * Three "Frequency" inputs for measuring RPM, Hz, duty cycle (PWM), hydraulic flow, and fuel flow.
- * Two "Engine Set Point" inputs.
- * Calculated channels for displaying sum, difference, and hydraulic horsepower.
- * Automatic sensor identification of "Analog" sensors for automatic set-up using Auto ID cables (optional).
- * RS232 input connector for future Digital Multimeter (DMM).
- * Portable TechStation carrying case holds DataView and a portable PC.
- * Internal battery operates for up to eight hours.
- * Operates and charges on 110/220 VAC, 11 to 40 VDC, or 12V Automotive Cigarette Lighter.
- * CE certified for European use.
- * PC-based diagnostic tool. Accepts up to nine standard Caterpillar sensors for measurements on any engine or machine. Allows data to be displayed on a Personal Computer (PC).
Specifications/Technical Information
Minimum PC Requirements
- Connection to PC - standard parallel (printer) port
- Computer - IBM PC compatible with 486, 33 Mhz SL or SXL processor or greater
- RAM - 8 Mb
- Available hard disc space - 10 Mb
- Diskette drive (internal or external add-on) - 3.5 Inch, 1.44 Mb
- Monitor - VGA
- DOS version - 5.0 or greater
- Operating system - Microsoft Windows® version 3.1 or Windows 95, OS2 version 2.11, or Warp 3.0
- Printer port - parallel
- Computer - IBM PC compatible with 486, 33 Mhz SL or SXL processor or greater
General Hardware Specifications
- Internal power source - rechargeable internal nickel metal hydride battery (Varta C526F, 7.2 Volt 2400 mAh) AC external power - 131-5052 AC Power Adapter, 90 to 264 VAC, 47 to 63 Hz
- External power connector - 11 to 40 VDC machine power or cigarette lighter adapter
- External power connector - 11 to 40 VDC machine power or cigarette lighter adapter
- Low battery indicator - flashing ON light
- Battery life - 10 hours nominal (dependent upon sensors being used)
- Battery charge time - 6 hours
- Battery charge indicator - light off - not charging, light on solid - fast charge, light flashing - trickle charge
- Operating temperature - -17 to +60°C (0 to 140°F)
- Storage temperature - -40 to +100°C (-40 to +212°F)
- Size - 297 x 229 x 45.7 mm (1.7 x 9.0 x 1.8 in)
- Weight - DataView hardware (enclosure only) 1.8 kg (4 lbs)
- External power connector - 11 to 40 VDC machine power or cigarette lighter adapter
Data Logger Specifications
- Channels - data can be logged from all nine input channels Memory - 2 Mbyte PC PCMCIA flash memory card is standard
- Sample rate - adjustable up to 1000 samples per second
- Recording time - varies depending on sample rate and number of channels in use
- Maximum log size - At first release of software, logs will be limited to 8000 samples. A later software version will provide larger size logs.
- Pre-trigger - allows logging of events which happen before the log trigger point
- Auto trigger - logging can be triggered from an event or change in any channel
- Manual trigger - logging can be manually started from the PC or from the hardware
- Sample rate - adjustable up to 1000 samples per second
Analog Channel Specifications
- Connector type - 5 pin DIN connectors (female)
- Analog channel sensor types - analog inputs are automatically reconfigured with relays to accept voltage, milliamp, RTD, or resistance-type output sensors.
- Analog channel input ranges - 0 to 5 VDC; Milliamp: 4 to 20 mA; RTD: 100 Ohm, PRTD; Resistance: 15K Ohm nominal
- Sensor power supply ranges - 5, 8, 12, or 15 VDC available, firmware selectable
- Input impedance - 500K Ohms minimum
- A/D resolution - 12 bit
- A/D Access time - 10 microseconds
- Channel scan rate - 50 microseconds per channel (10 channels scanned in 500 microseconds)
- Frequency response - DC to 300 Hz (2000 samples per second)
- A/D input voltage range - 0 to 5 VDC
- Max input voltage - protected to 40V RMS or peak
- Analog channel sensor types - analog inputs are automatically reconfigured with relays to accept voltage, milliamp, RTD, or resistance-type output sensors.
Frequency Channel Input Specifications
- Frequency sensor types - waveform or pulse inputs
- Input voltage range - 0.1 to 40 VAC or VDC peak
- Allowable signal offset - +0.040 VDC
- Input impedance - 50K Ohms minimum
- Frequency response - 3 Hz to 15K Hz
- Frequency accuracy - ±1 Hz
- RPM measurement range - 1 to 9999 RPM
- RPM accuracy - ±1 RPM in selected RPM/PPR ranges
- Pulses per revolution - 0.1 to 256 pulses per revolution;
- Hz fixed at 60 pulses per revolution
- Pulse width measurement - 1 to 100% duty cycle for 40 Hz to 15K Hz
- Cat PWM sensor measurement - special adapter cable required because of DC offset on output signal
- Pulse width accuracy - ±1% for signals above 1V peak
- Photo pickup - power provided for 9U-5140 Photo Pickup
- Photo pickup range - 3 to 30 inches from retro-reflective tape target
- Input voltage range - 0.1 to 40 VAC or VDC peak
Engine Set Point Specifications
- Set point inputs - 2 inputs provided for use with 2 frequency channels
- Rack contact voltage - 12 VDC
- Rack contact current - 5.5 mA
- Overrun indication - 0 to 10% rack contact closure
- Set point indication - 11% rack contact stores engine rpm
- Lug indication - 75 to 100% rack contact closure
- Rack contact voltage - 12 VDC
131-5050 Basic Cat DataView
This is a very basic group which includes only DataView hardware unit and accessories necessary to power it and connect it to the PC. No sensor or adapter cables are included. The memory card for data logging is not supplied but can be purchased separately, if desired.
131-5050 DataView Group
Not Shown:
131-5051 DataView Portable TechStation Group
This group contains all accessories, excluding sensors, needed to operate DataView on a PC. A carrying case is also included which holds DataView unit and PC (not included).
131-5051 DataView Portable TechStation Group
Not Shown:
Optional Equipment
Optional Equipment
Not shown:
Optional Cables And Sensors
The following sensors and cables are used with DataView.
Analog Channel Sensors
Pressure Sensors for Analog Channels
- A 131-5054 Adapter Cable or Auto ID Cable is always required to use these sensors
- 4C-6816 Pressure Sensor (0 to 60 psi)
- 131-5060 Auto ID Cable (for 4C-6816 Sensor)
- 4C-6817 Pressure Sensor (0 to 100 psi)
- 131-5061 Auto ID Cable (for 4C-6817 Sensor)
- 4C-6818 Pressure Sensor (0 to 500 psi)
- 131-5062 Auto ID Cable (for 4C-6818 Sensor)
- 4C-6819 Pressure Sensor (0 to 1000 psi)
- 131-5063 Auto ID Cable (for 4C-6819 Sensor)
- 4C-6820 Pressure Sensor (0 to 7500 psi)
- 131-5064 Auto ID Cable (for 4C-6820 Sensor)
- 4C-6816 Pressure Sensor (0 to 60 psi)
Probe Type RTD Temperature Sensors
- 4C-6264 RTD Temperature Sensor, 25.4 mm (1.0 in) long, 3.2 mm (.125 in) diameter
- 4C-6265 RTD Temperature Sensor, 38.1 mm (1.5 in) long, 3.2 mm (.125 in) diameter
- 4C-6266 RTD Temperature Sensor, 63.5 mm (2.5 in) long, 3.2 mm (.125 in) diameter
- 4C-6267 RTD Temperature Sensor, 88.9 mm (3.5 in) long, 3.2 mm (.125 in) diameter
- 4C-6265 RTD Temperature Sensor, 38.1 mm (1.5 in) long, 3.2 mm (.125 in) diameter
Exhaust RTD Temperature Sensor
- 4C-6268 Exhaust RTD Temperature Sensor
Hand Held RTD Temperature Probes
- 4C-6496 Immersion Hand Held RTD Temperature Probe, 3.18 mm (.125 in) diameter
- 4C-6497 Surface Hand Held RTD Temperature Probe, 6.35 mm (.25 in) diameter
Blowby Sensors for Analog Channels
- 8T-2685 Small Blowby/Air Flow Pickup (Part of 8T-2700 Blowby Group)
- 131-5066 Auto ID Cable for Small Blowby Pickup 1U-8860 Large Engine Blowby/Air Flow Pickup Group (For 3500 and 3600 Engines)
- 131-5067 Auto ID Cable for Small Blowby Pickup
- 131-5066 Auto ID Cable for Small Blowby Pickup 1U-8860 Large Engine Blowby/Air Flow Pickup Group (For 3500 and 3600 Engines)
Position Sensor for Analog Channels
- 8T-1002 Position Sensor 0 to 25 mm (0 to 1.0 in) range
- 131-5065 Auto ID Cable for 8T-1002 Position Sensor
- 6V-6042 Contact Point Group
- 5P-4814 Fuel Setting Collet
- 9U-6909 Extended Fuel Setting Collet (for 3500 engines)
- 131-5065 Auto ID Cable for 8T-1002 Position Sensor
Frequency Channel Sensors
Photo Pickup Speed Sensor
- 9U-5140 LED Photo Pickup
- 6V-3137 Magnetic Mounting Base for 9U-5140
- 6V-3138 Extension Rod for 6V-3137
- 1U-6605 Retro-Reflective Tape, 12 mm (.5 in) x 15 m (5.0 ft) long
- 6V-0093 Retro-Reflective Tape, 12 mm (.5 in) x 47.5 m (50 ft) long
- 4C-6919 Retro-Reflective Tape, 25 mm (1.0 in) x 2.5 m (100 in) long
- 6V-3137 Magnetic Mounting Base for 9U-5140
Injection Line Speed Sensor
- 6V-4950 Injection Line Pickup Group (from Multitach Group)
- 4C-6821 Injection Line Pickup Group (from Data Logger Group)
Tach Generator Speed Sensor
- 9U-7506 Magnetic Adapter Cable
- 5P-7360 Tach Generator (20 tooth internal gear)
- 5P-1759 Tachometer Drive Group
- 5P-7360 Tach Generator (20 tooth internal gear)
Flywheel TDC Magnetic Speed Sensors
- 9U-7506 Magnetic Adapter Cable
- 8T-5184 Magnetic TDC Pickup 89 mm (3.5 in) long
- 6V-2197 Magnetic TDC Pickup 114 mm (4.5 in) long
- 8T-5185 Magnetic TDC Pickup 178 mm (7.0 in) long
- 9U-7506 Magnetic Adapter Cable (required for TDC Sensors)
- 6V-2199 Sensor Mounting Adapter, 1/8 in NPTF
- 6V-3093 Sensor Mounting Adapter, 1/4 in NPTF
- 7X-1171 Sensor Mounting Adapter, 7/16-20 Straight Thread
- 8T-5184 Magnetic TDC Pickup 89 mm (3.5 in) long
Magnetic Pickup Speed Sensors
- 8L-4171 General Purpose Magnetic Speed Sensor, 91 mm (3.5 in) long, 5/8-18 Thread
- 9G-6724 Magnetic Speed Sensor, 76 mm (3.0 in) long, 3/4-16 Thread
- 6V-4156 Adapter Cable (required for above sensors), Amphenol to Phono Jack
- 9U-7506 Magnetic Adapter Cable (required for above sensors) Phono Jack to DataView
- 9G-6724 Magnetic Speed Sensor, 76 mm (3.0 in) long, 3/4-16 Thread
Fuel Flowmeters And Fuel Flow Communicator
- 1U-9500 Fuel Flow Communicator
- 1U-5450 Complete Engine Fuel Flow Monitor Arrangement
- 4C-9764 Fuel Flow Monitor Group
- 4C-9758 Fuel Flowmeter Group, Supply, Small
- 4C-9759 Fuel Flowmeter Group, Return, Small
- 4C-9760 Fuel Flowmeter Group, Supply, Large
- 4C-9761 Fuel Flowmeter Group, Return, Large
- 1U-5305 Adapter Group, Hose, Small
- 1U-5306 Adapter Group, Hose, Large
- 1U-5420 Adapter Group, Hose, 3600 Engine
- 1U-5299 Case Assembly
- 1U-5430 Small to Medium Engine Fuel Flow Monitor Arrangement
- 1U-5440 Medium to Large Engine Fuel Flow Monitor Arrangement
- 1U-5450 Complete Engine Fuel Flow Monitor Arrangement
Hydraulic Flowmeters for Frequency Channels
- The 131-5056 Adapter Cable is required to use the following flowmeters.
- 4C-9911 Hydraulic Flowmeter, 8 to 50 Lpm (2 to 12 gpm)
- 4C-9436 Hydraulic Flowmeter, 12 to 120 Lpm (3 to 25 gpm)
- 4C-9912 Hydraulic Flowmeter, 20 to 220 Lpm (5 to 50 gpm)
- 4C-9913 Hydraulic Flowmeter, 30 to 300 Lpm (8 to 80 gpm)
- 4C-8687 Hydraulic Flowmeter, 45 to 450 Lpm (10 to 100 gpm)
- 4C-9914 Hydraulic Flowmeter, 50 to 550 Lpm (12 to 150 gpm)
- 4C-8686 Hydraulic Flowmeter, 60 to 700 Lpm (15 to 180 gpm)
- 4C-9911 Hydraulic Flowmeter, 8 to 50 Lpm (2 to 12 gpm)
Reference
- Tool Operating Manual; NEHS0662, Using the Caterpillar DataView;
- Marketing Brochure; NEHP5622, Caterpillar DataView