Illustration 1 | g01349694 |
(1) 107-7175 Spring
- Length under test force ... 107.16 mm (4.219 inch)
- Test force ... 555.6 ± 20.0 N (124.9 ± 4.5 lb)
- Free length after test ... 144.5 mm (5.69 inch)
- Outside diameter ... 27.00 mm (1.063 inch)
- Test force ... 555.6 ± 20.0 N (124.9 ± 4.5 lb)
Illustration 2 | g01418999 |
(A) Dimension for the gear
- Length of the new gear ... 110.000 ± 0.015 mm (4.3307 ± 0.0006 inch)
- Depth of the bore in oil pump body for the new gear ... 110.15 ± 0.02 mm (4.337 ± 0.001 inch)
(B) Dimension for the shaft
- Diameter of the new shaft ... 31.742 ± 0.008 mm (1.2497 ± 0.0003 inch)
- Bore in bearing for the shaft after assembly ... 31.811 ± 0.013 mm (1.2524 ± 0.0005 inch)
(C) Protrusion of the dowel from the pump cover ... 6.0 ± 0.5 mm (0.24 ± 0.02 inch)
(D) Distance from the end of the idler shaft to gear face ... 34.0 ± 0.5 mm (1.34 ± 0.02 inch)
(E) Distance from the end of the shaft to gear face ... 47.0 ± 0.5 mm (1.85 ± 0.02 inch)
(F) The sleeve bearing is installed in the pump cover at the following depth. ... 1.5 ± 0.5 mm (0.06 ± 0.02 inch)
(G) The sleeve bearing is installed in the oil pump body at the following depth. ... 1.5 ± 0.5 mm (0.06 ± 0.02 inch)
Illustration 3 | g01419001 |
Illustration 4 | g01430632 |
(H) Position of bearing joint from the centerline through the bearing bore ... 45 ± 15 degrees
When the engine oil pump is viewed from the drive end the drive gear rotates in the following direction. ... Clockwise
Bench test specifications
- Unrestricted flow rate per minute at 1000 rpm ... 410 L (108 US gal)
- Pump pressure at 300 rpm with fully blocked outlet ... 590 to 670 kPa (86 to 98 psi)
Note: Before you install the pump, lubricate the moving parts with clean engine oil. Rotate the pump by hand in order to ensure that the pump rotates freely.