C6.6 Generator Set Caterpillar


E539 High Intake Manifold Air Temperature

Usage:

C6.6DE150E ECR
Conditions Which Generate This Code:

The Electronic Control Module (ECM) detects a fault with the intake manifold air temperature. The ECM detects the following faults:

  • The engine has been running for more than 3 minutes.

  • The trip point for the event code for intake manifold air temperature is reached.

  • Diagnostic code 172-3 Intake Manifold Air Temperature open/short to +batt is not active.

  • Diagnostic code 172-4 Intake Manifold Air Temperature short to ground is not active.

Table 1
Trip Points for the Intake Manifold Air Temperature
   
    E539-1     E539-2    
Engine Model            
Turbocharged Aftercooled Engines (TA)    
82 °C (179 °F)    

86 °C (186 °F)    

System Response:

The warning lamp will be illuminated. If equipped, the diagnostic lamp will flash the event code.

The event code will be logged.

E539-1

None

E539-2

The engine will be derated.

Test Step 1.

Refer to Troubleshooting, "Intake Air Temperature Is Too High".

Results:

  • OK - STOP

Caterpillar Information System:

C6.6 Generator Set E361 High Engine Coolant Temperature
C6.6 Generator Set Diagnostic Code Cross Reference
C4.4 Generator Set Engines Intermittent Engine Shutdown
C6.6 Marine Generator Set Excessive Fuel Consumption
C6.6 Marine Generator Set Engine Will Not Crank
TH31 Well Servicing Transmissions Pump Drive - Disassemble
C9 On-highway Engine Flywheel Housing
325D and 329D Excavators and 325D Material Handler Machine System Specifications Pilot Valve (Boom Drift Reduction)
C15-XQ400 Rental Generator Set Fan Drive Bearing - Lubricate
TH31-E61 and TH35-E81 Petroleum Transmissions Capacities (Refill)
2006/01/30 New Oil Drain Tube for the Turbocharger {1052, 1307}
C27 and C32 Generator Set Engines Crankshaft Front Seal - Install
C27 and C32 Generator Set Engines Engine Support (Front) - Remove and Install
TH31-E61 and TH35-E81 Petroleum Transmissions Reference Material
2005/12/12 Remove Certain 6D-7726 Hose Assemblies from Inventory {0738}
TH31-E61 and TH35-E81 Petroleum Transmissions Breather (Transmission) - Clean
C27 and C32 Generator Set Engines Housing (Front) - Remove
C-9 Engine for TK711, TK721, TK722, TK732, TK741, TK751, and TK752 Track Feller Bunchers Engine Will Not Crank
C27 and C32 Generator Set Engines Housing (Front) - Install
C13, C15, and C18 Tier 4 Final Engines Flywheel
C15 and C18 Engines for Caterpillar Built Machines Flywheel
C-15, C-16, and C-18 Truck Engines Flywheel
100-200 kW Tactical Quiet Generator (TQG) Digital Voltage Regulator General Information
100-200 kW Tactical Quiet Generator (TQG) Digital Voltage Regulator Dimensions
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.