1983/02/28 Caterpillar


Test Procedure For Hydramechanical Shutoff After Engine Storage{7418}

Usage:


All D379B, D398B And D399 Engines So Equipped

It is our recommendation to check the operation of the hydramechanical shutoffs before the above engines are put back into service after a period of extended storage. The procedures which follow can be used to make sure the air shutoff and the rack shutoff work correctly.

Air Shutoff Group

1. Remove bolts (1) that hold the hydraulic cylinder or solenoid in place. See Illustration 1.


Illustration 1. Air shutoff group.

2. Remove the hydraulic cylinder or solenoid. When the cylinder or solenoid are removed, the plate assembly will automatically move to the fully closed position.

3. Turn knob (2) and check the movement of plate assembly (3). The plate assembly must move freely from the fully closed position to the fully open position. If the plate assembly moves freely, the hydraulic cylinder or solenoid can be put back in position. Make sure the shutoffs are in the open position.

If the plate assembly does not move freely to the fully closed position, see the next step.

4. Remove knob (2). Remove the cover assembly (4).

5. Install knob (2) and put penetrating type oil on the shaft, especially where the shaft goes into the housing. Turn the shaft until it moves freely.

6. Assemble the air shutoff group.


NOTICE

Be sure both air inlet shutoff valves (one on each side of the engine) are open before the engine is started. Both valves must be open to prevent possible engine damage.


Rack Shutoff Group (5N5792 Only)

1. Disconnect the oil supply tube assembly at the rack shutoff group.

2. Remove the rack shutoff group and three bolts (1) that hold it in place on the governor. Do not remove bolt (2) at this time. See Illustration 2.


NOTICE

Spring pressure is present behind the cover. Make sure the cover and housing are held together while bolt (2) is removed. Gradually let the cover and housing separate.



Illustration 2. Rack shutoff group.

3. While the cover and housing are held together, remove bolt (2). Gradually let the cover and housing separate.

4. Remove the spring and piston.

5. Check the condition of the seal on the end of the piston. If the seal is hard and/or cracked, install a new seal.

6. Make sure the piston moves freely in the housing.

7. Clean all the parts and the gasket surfaces of the rack shutoff housing and the governor drive housing.

8. Assemble the rack shutoff group and install it on the engine. Use new gaskets.

During normal operation, it is our recommendation that the operation of the hydramechanical shutoff be checked every 500 service meter units or 3 months whichever comes first.

If it is not possible to disassemble the components, this procedure can be used to check the operation of the hydramechanical shutoff after extended storage of an engine.

1. With the engine running, pull the red emergency knob. The engine must stop.


NOTICE

Be sure both air inlet shutoff valves (one on each side of the engine) are open before the engine is started. Both valves must be open to prevent possible engine damage.


2. Put both the air shutoff valves in the open position. They are located on each side of the engine.

3. Fasten the air shutoff valves in the open position. The knobs can be fastened with wire or held open manually by two servicemen.

4. Pull the red emergency knob. The engine must stop.

5. If the engine does not stop after either Step 1 or 4, see your Caterpillar dealer for the necessary repairs. The emergency shutoff system must work correctly for your engine to have protection during operation.

Caterpillar Information System:

1983/02/14 New Water Pump Has Improved Seal{1361}
1983/02/14 Check Cylinder Bores For Chamfer During Reconditioning{1202,1222,1223}
1983/02/14 New Clutches For Rear Power Take-Off{3055,3054}
1983/01/31 Special Instruction Available For "Troubleshooting And Repair Of The 6V2100 Multitach"{0651}
1983/01/31 FT806 Cylinder Head Repair Bench Group Is Improved{1101,1201}
1983/01/31 Notice: Bolts, Washers Can Fall Into Suction Screen Housing And Damage Oil Pump{1302}
1983/01/31 Know What Type Of Repair To Make And When{0374}
1983/01/31 Parts Service Information For Pistons{1214,1225}
1983/01/31 Service Information For Hydramechanical Shutoff Units{7418}
1983/01/31 Change In Repair Centers For 5P2160 Horsepower Meter Group{0651}
1983/01/24 New Expansion Tank And Support Used{1354}
1983/01/24 Corrections To Product Update Guide (Form PEGP2808) And Engine Update Guide (Form PEGP2811){0374}
1983/02/28 New Specifications For Installation Of Crankshaft Counterweight Bolts{1202}
1983/02/28 Use FT1783 Fixture To Drill Vent Holes In Impeller{0665,1361}
1983/02/28 Engine Valve Stem "Use Again" Specifications{0653,1105}
1983/02/28 New Rack Shutoff Solenoid Available{1257,1259}
1983/02/28 Use Vacuum Tester For Quality Control Check Of Water Pump Seal{0652,1361}
1983/02/28 New Instruction Decal Used On 6V4060 Engine Set Point Indicator{0374}
1983/03/14 New Manual BrakeSaver Control Group{1159}
1983/03/14 Fabricated Bracket Decreases Stress On Refrigerant Compressor Bracket{1405,1802}
1983/03/14 "Gas Engine Application And Installation Guide" Now Available{0374}
1983/03/14 Additions To Reference Chart For Major Production Changes{0374,0375,1000}
1983/03/14 Change Made To 6V3032 Deluxe Test Lead Kit{0651}
1983/03/21 New Bolt Used In Front Engine Support{1154}
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.