Re-Calibrate Payload / Empty Machine Calibration
- Select "Trans/Chassis ECM" > "OK".
Show/hide table
Illustration 2 g03865835 Select "Service" > "Calibrations". - Select "Service" > "Calibrations".
Show/hide table
Illustration 3 g03865836 Select "Payload System Calibrations" > "Start". - Select "Payload System Calibrations" > "Start".
Show/hide table
Illustration 4 g03865840 Follow the on-screen instructions. Select "OK". - Follow the on-screen instructions. Select "OK".
Show/hide table
Illustration 5 g03865859 Select "Payload System Empty Machine Weight Calibration" > "Begin". - Select "Payload System Empty Machine Weight Calibration" > "Begin".
Show/hide table
Illustration 6 g03865860 When set up conditions are met, select "Next". - When set up conditions are met, select "Next".
Show/hide table
Illustration 7 g03865861 Once calibration has successfully completed, the "Calibration Successful" message will appear. Select "Finish". - Once calibration has successfully completed, the "Calibration Successful" message will appear. Select "Finish". The "ECM Summary" screen will appear.
Illustration 1 | g03865834 |
Select "Trans/Chassis ECM" > "OK". |
Illustration 8 | g03865863 |
"ECM Summary" screen |
Empty weight calibration procedure via Cat Information Display
Service > Calibrations
Note: Entry into the Calibrations menu page requires the service mode password.
For more information, refer to the following section in this manual:
- Service > Service Mode
- Press the "Calibrations" menu button. The menu button will first turn to blue, then turn to yellow and the "Calibrations" menu page will appear.
Show/hide table
Illustration 10 g06247332 - Press the "Empty Weight Calibration" menu button. The menu button will first turn to blue, then turn to yellow and the "Empty Weight Calibration" page will appear.
Show/hide table
Illustration 11 g06247337 - Read the instructions and warning carefully before proceeding with the calibration. Press the "OK" button to continue with the calibration. Press the "BACK" button to return to the previous page.
Show/hide table
Illustration 12 g06247370 - Read the instructions and warning carefully before proceeding with the calibration. Press the "OK" button to continue with the calibration.
Note: During the calibration, the following machines will show the following states:
Body Up status (True or False)
- (Models 745D HRC (3T6))
- (Models 745D LRC (3F6))
Ejector Blade status (Retracted or Not Retracted)
- (Models 740D HRC EJ (3T7))
- (Models 740D LRC EJ (3F7))
Show/hide tableIllustration 13 g06247374 - Continue following the instructions on the calibration pages. To continue with the calibration, press the bottom "NEXT" button. To abort the calibration, press the top "ABORT" button.
Show/hide table
Illustration 14 g06247376 - Allow the calibration to continue.
Illustration 9 | g06247330 |
Illustration 15 | g06247377 |
If the calibration is successful, a message will appear in the lower information banner.
Press the "OK" button to continue.
Illustration 16 | g06247385 |
If the calibration is unsuccessful, a message will appear in the lower information banner. The reason(s) that the calibration was aborted is also shown on the page.
Press the OK button to continue.
Illustration 17 | g06247391 |
The calibration can be aborted any time. The top button on this page is the "ABORT" button.
Press the "ABORT" button to abort the calibration. The Abort Calibration verification page will appear.
Illustration 18 | g06247397 |
The Abort Calibration verification page will appear so that the operator can verify that the calibration is to be aborted.
Press the "OK" button to abort the calibration procedure.
Press the "BACK" button to return to the previous page.