G3516B and G3520B Generator Set Engines Caterpillar


Fuel Control Valve - Remove and Install

Usage:

G3516B 7EZ

Removal Procedure


NOTICE

Keep all parts clean from contaminants.

Contaminants may cause rapid wear and shortened component life.


  1. Turn off the gas supply.


    Illustration 1g00764979

  2. Remove bolts (1) from the flange and tubes on each side of fuel control valve (2).

  3. Disconnect electrical connection (2) from fuel control valve (2).


    Illustration 2g00764988

  4. Remove four bolts (4) that fasten fuel control valve (2) to the mounting plate. Remove fuel control valve (2).

Installation Procedure


NOTICE

Keep all parts clean from contaminants.

Contaminants may cause rapid wear and shortened component life.




    Illustration 3g00764988

  1. Position the fuel control valve (2) on the mounting plate and install four bolts (4).


    Illustration 4g00764999

  2. Install gasket (5) on each end of fuel control valve (2).


    Illustration 5g00764979

  3. Put the flange and tubes in position and install bolts (3).

  4. Install electrical connection (3) on the fuel control valve (2).

  5. Turn on the gas supply.