G3304 and G3306 Engines Caterpillar


Coolant Temperature Contactor

Usage:

G3306 07Y



Illustration 1g01663653

(1) Final installation torque for the water temperature contactor assembly ... 52 ± 8 N·m (38 ± 6 lb ft)

Actuation temperature ... 98.0 ± 1.5 °C (208 ± 3 °F)

Minimum deactuation temperature ... 91° C (196 °F)

Operating temperature ... −40 to 120 °C (−40 to 248 °F)

Contact position (1-2) ... Normally open below actuation temperature

Contact position (2-3) ... Normally closed below actuation temperature