- Asphalt Screed
- SE50 V (S/N: J971-374)
- SE50 VT (S/N: B861-135; J6K1-254)
- SE60 V (S/N: JJ31-756)
- SE60V XW (S/N: JS91-221)
- SE60VT XW (S/N: E991-146; TLW1-286)
- SE50 VT (S/N: B861-135; J6K1-254)
Description Of Change: The following improvements have been made:
- New heater design to eliminate water ingression.
- Improved cable assembly with overmold and hex head connector to eliminate water ingression.
- New heater hold-downs to improve system IR during screed heat up.
- New software with changes to ground fault logic.
Adaptable To:
Do not operate or work on this product unless you have read and understood the instruction and warnings in the relevant Operation and Maintenance Manuals and relevant service literature. Failure to follow the instructions or heed the warnings could result in injury or death. Proper care is your responsibility. |
Parts List | ||||
---|---|---|---|---|
Item | Qty | New Part No | Description | Former Part No |
1 | 1 | Implement Software Gp SFWR GP-A2000 - Implement Control | 527-7511 | |
2 | 2 | Screed Heater As - HEATER AS-ENDGATE - Heated end-gate heater | 442-6176 | |
3 | 1 | Power Train Software Gp - SFWR GP-A5012 - Generator ECM | 548-8669 | |
4 | 1 | Monitor Software Gp - SFWR GP-A5012 - Generator ECM | 539-5530 |
Follow the instructions in SEHS0522 to update the Generator Power Inverter and Implement Control software. The specific file to be used on the Generator power Inverter ECM depends on the part number of the ECM.
Use
Use
Use
In additions to the parts list in this publication, other parts are required that vary with the screed serial number. Consult the following publications for a complete list of parts required.
SE50 VS/N:J9700100-00374
Follow special instruction , M0099943 to update the SE50V screed.
Note: The screed plates will need to be dropped for the older group of screeds, but can remain installed for the newer, higher serial number screeds.
SE50 VTS/N:B8600100-00135 / ; S/N:J6K00001-00254
Follow special instruction , M0101905 to update the SE50VT screed.
Note: The screed plates will need to be dropped for the older group of screeds, but can remain installed for the newer, higher serial number screeds.
SE60 VS/N:JJ300001-00756
Follow special instruction , M0098949 to update the SE60V screed.
Note: The screed plates will need to be dropped for the older group of screeds, but can remain installed for the newer, higher serial number screeds.
SE60 V XWS/N:JS900001-00221
Follow special instruction , M0101523 to update the SE60V XW screed.
Note: The screed plates will need to be dropped for the older group of screeds, but can remain installed for the newer, higher serial number screeds.
SE60 VT XWS/N:E9900001-00146 / ; S/N:TLW00001-00286
Follow special instruction , M0103287 to update the SE60VT XW screed.
Note: The screed plates will need to be dropped for the older group of screeds, but can remain installed for the newer, higher serial number screeds.
In addition to the parts specified in the special instructions above, screeds configured with heated end-gates will need the end-gate heaters replaced.
When servicing the screeds, follow all service literature, including special instructions , REHS9161 for proper connector torque and the use of lock wire.