Wiring Harness (Short Circuit) - Test

Usage:

- PL7

------ WARNING! ------

Accidental engine starting can cause injury or death to personnel working on the equipment.

To avoid accidental engine starting, disconnect the battery cable from the negative (−) battery terminal. Completely tape all metal surfaces of the disconnected battery cable end in order to prevent contact with other metal surfaces which could activate the engine electrical system.

Turn the battery disconnect switch to the OFF position and lockout the battery disconnect switch with a safety lock.

Place a Special Instruction, SEHS7332, "Do Not Operate" tag at the start switch and battery disconnect location to inform personnel that the machine is being worked on.


A short circuit is a failure of an electrical circuit that results in undesired electrical current. Usually, a short circuit is a bypass of the circuit across a load. For example, a short across the wires in a circuit for a lamp produce too much current in the wires but no current is felt at the lamp. The lamp is shorted out. The resistance in a normal circuit can vary, but the resistance between a particular circuit and other unrelated circuits is always greater than 5000 ohms. The following procedure explains the test for a short circuit:

Reference: For a complete electrical schematic, refer to Electrical System Schematic for the machine that is being serviced.

TEST FOR A SHORT CIRCUIT.

  1. Identify the connectors and the wire numbers of the suspect circuits. Use the Electrical System Schematic of the machine to identify the circuits.

  2. Turn the key start switch and the disconnect switch to the OFF position.

  3. Disconnect the component and the ECM from the wiring harness.

  4. At the machine harness connector for the ECM, place one of the multimeter probes on the contact of the suspect wire.

  5. Use the other multimeter probe to check the resistance across all other contacts in the connectors of the ECM and frame ground.

    Expected Result: The resistance is greater than 5000 ohms for all the measurements.

    OK - The resistance is greater than 5 ohms for all the measurements. The harness circuits are correct.

    Stop.

    NOT OK - The resistance is less than 5 ohms. There is a short in the machine harness. The short is between the suspected wire and the wire with the lowest resistance measurement.

    Repair: Repair the machine harness or replace the machine harness.

    Stop.

Caterpillar Information System:

Product Link ® Elite PLE742 Systems Wiring Harness (Open Circuit) - Test
Product Link ® Elite PLE742 Systems Electrical Connector - Inspect
Product Link ® Elite PLE742 Systems ECM - Replace
Product Link ® Elite PLE742 Systems Configuration File - Uninstall
Product Link ® Elite PLE742 Systems Configuration File - Install
Product Link ® Elite PLE742 Systems ECM Software - Install
Product Link ® Elite PLE742 Systems Service Meter - Synchronize
Product Link ® Elite PLE742 Systems External Antenna - Test
Product Link ® Elite PLE742 Systems Web Configuration Home Page Is Not Accessible
Product Link ® Elite PLE742 Systems User Interface Does Not Update GPS Location
Product Link ® Elite PLE742 Systems User Interface Does Not Alert when Geo-Fence Is Crossed
Product Link ® Elite PLE742 Systems Operating Hours Discrepancy
MD6200 Rotary Drill Fuel Tank Water and Sediment - Drain
PM310, PM312, and PM313 Cold Planer Machine Interlocks
Improved Pipe Assemblies for Coolant Tube are Now Used on Certain 794 AC Off-Highway Trucks {1380} Improved Pipe Assemblies for Coolant Tube are Now Used on Certain 794 AC Off-Highway Trucks {1380}
C175-16 and C175-20 Engines for Caterpillar Built Machines Fuel Filter Housing - Remove
Procedure to Install Ventilation Reduction Package on R1600H Load Haul Dump Machines {1000, 7620} Procedure to Install Ventilation Reduction Package on R1600H Load Haul Dump Machines {1000, 7620}
990K Wheel Loader Systems Window Wiper and Wiper Motor
992K Wheel Loader Systems Window Wiper and Wiper Motor
980L Tier 3 Wheel Loader Machine System Control Valve (Auxiliary) - Remove and Install
New Electronic Monitoring System (EMS) Series III Is Now Available on Certain Machines Equipped with Cat® Product Link {7490, 7610, 7620} New Electronic Monitoring System (EMS) Series III Is Now Available on Certain Machines Equipped with Cat® Product Link {7490, 7610, 7620}
New Product Link Software Is Now Available on Certain Cat® Product Link Devices When Using R-Terminal Connection {7606, 7610, 7620} New Product Link Software Is Now Available on Certain Cat® Product Link Devices When Using R-Terminal Connection {7606, 7610, 7620}
980L Tier 3 Wheel Loader Engine Supplement Hood - Remove and Install - One Piece Hood
980L Tier 3 Wheel Loader Machine System Main Control Valve - Remove and Install
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.