Note: Cat HYDO Advanced 10 has a 50% increase in the standard oil drain interval for machine hydraulic systems (3000 hours versus 2000 hours) over second and third choice oils - when following the maintenance interval schedule for oil filter changes and for oil sampling that is stated in the Operation and Maintenance Manual for your particular machine. 6000 hour oil drain intervals are possible when using S·O·S Services oil analysis. Contact your Cat dealer for details.
Operate the machine for a few minutes in order to warm the hydraulic system oil.
The machine should be level . Lower the bucket to the ground and apply slight downward pressure. Engage the parking brake and stop the engine.
The hydraulic tank filler cap is located under the access door on the top of the engine compartment.
- Open the engine access door on the top of the machine.
Show/hide table
Illustration 1 g01289083 - Remove the hydraulic tank filler cap.
Show/hide table
Illustration 2 g01412119 Show/hide tableIllustration 3 g01412174 - Open the drain valve that is located on the hydraulic pump. Allow the oil to drain into a suitable container.
- Tighten the drain valve.
- Change the hydraulic system filter. Refer to Operation and Maintenance Manual, "Hydraulic System Oil Filter - Change".
- Inspect the hydraulic tank breather that is located in the breather hose on top of the hydraulic tank. Replace the breather, if necessary.
- Fill the hydraulic system oil tank. Refer to Operation and Maintenance Manual, "Lubricant Viscosities" and Operation and Maintenance Manual, "Capacities (Refill)".
Show/hide table
Illustration 4 g01412213 - Maintain the hydraulic oil level in the sight gauge between the "MIN" mark and the "MAX" mark.
Check the hydraulic oil level with the loader on the ground and with the backhoe in the transport position.
Note: The oil must be free of bubbles. If bubbles are present in the oil, air is entering the hydraulic system. Inspect the suction hoses and hose clamps.
- Inspect the gasket on the hydraulic tank filler cap for damage. Replace the gasket, if necessary.
- Install the hydraulic tank filler cap.
- Close the access door.