279C, 279C2, 289C, 289C2 and 299C Compact Track Loaders, 287C, 277C, 277C2, 287C2 and 297C Multi Terrain Loaders and 246C, 256C, 262C, 262C2 and 272C Skid Steer Loaders Machine Electronic Control System Caterpillar


MID 039 - CID 0356 - FMI 05

Usage:

256C DWS
Conditions Which Generate This Code:


Illustration 1g01267850

Schematic for the Bucket Raise Solenoid

This diagnostic code is associated with the Bucket Raise Solenoid. The FMI 05 means that the ECM has detected that the current for the solenoid circuit is below normal.

Conditions that could causes this diagnostic code to be activated are:

  • The energize circuit of the solenoid is open.

  • The return circuit of the solenoid is open.

  • The solenoid has failed.

  • The ECM has failed. This is unlikely.

Note: Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, secure and in good condition. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing this procedure.

Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected.

Note: The resistance of the solenoid coil should be 27 ± 1.4 ohms at 20 °C (68.0 °F).

Test Step 1. CHECK THE SOLENOID

  1. Disconnect the solenoid from the machine harness.

  1. At the machine harness connector for the solenoid, place a jumper wire from contact 1 (wire P846-PK) to contact 2 (wire H803-BU).

  1. Turn the key start switch to the ON position. Do not start the engine.

  1. Observe the status of the CID 0356 FMI 05 diagnostic code.

Expected Result:

The CID 0356 FMI 05 diagnostic code is no longer active. A CID 0356 FMI 06 diagnostic code becomes active when the jumper wire is connected.

Results:

  • YES - The CID 0356 FMI 05 diagnostic code is no longer active. A CID 0356 FMI 06 diagnostic code becomes active when the jumper wire is connected. The solenoid has failed.

    Repair: Repeat this Test Step "CHECK THE SOLENOID" in order to verify the solenoid failure. Replace the solenoid. Verify that the new solenoid corrects the problem.

    STOP

  • NO - The CID 0356 FMI 05 diagnostic code remains active. The jumper wire does not affect the status of the active diagnostic code. The solenoid is not causing the problem. Proceed to Test Step 2.

Test Step 2. CHECK THE CIRCUIT FOR AN OPEN

The jumper wire that was installed in the previous Test Step remains in place.

  1. Disconnect the negative battery cable and turn the key start switch to the OFF position.

  1. Disconnect the machine harness ECM connector J1 from the ECM.

  1. At the machine harness connector J1 for the ECM, measure the resistance from contact J1-66 (wire P846-PK) to contact J1-55 (wire H803-BU).

  1. While observing the multimeter resistance measurement, wiggle the machine harness connectors for the ECM and wiggle the machine harness connector for the solenoid. Gently pull on the wires and move the wires around.

Expected Result:

The resistance measurement is less than 5.0 ohms at all times during the manipulation of the harness and connectors.

Results:

  • OK - The resistance measurement is less than 5.0 ohms. The resistance measurement is not indicating an open or a bad connection in the circuit. Proceed to Test Step 3.

  • NOT OK - The resistance measurement is greater than 5.0 ohms. The resistance measurement is indicating and open circuit or a bad connection in the machine harness.

    Repair: A resistance measurement that is greater than 5000 ohms could indicate that a wire is either not connected or is open. A resistance measurement that is greater than 5.0 ohms but less than 5000 ohms could indicate that one of the connection points in the circuit is not open but is not a good connection.The open or possible bad connection is in supply wire P846-PK or in return wire H803-BU of the machine harness. Refer to the complete machine Electrical System Schematic. Check all of the connectors that are in the solenoid circuit. Ensure that all connections are clean, secure and in good condition. Repair the machine harness or replace the machine harness.

    STOP

Test Step 3. CHECK THE OPERATION OF THE ECM

The key start switch remains in the OFF position. The machine harness connector for the solenoid and the ECM J1 connector remain disconnected.

  1. Remove the jumper wire that was installed in the last test step.

  1. At the machine harness connector J1 for the ECM, use a 151-6320 Removal Tool to remove the solenoid energize wire P846-PK and socket at contact J1-66 from the harness connector.

  1. Reconnect the machine harness J1 connector to the ECM.

  1. Reconnect the negative battery cable and turn the key start switch to the ON position.

  1. Use a 7X-1710 Multimeter Probe that is not connected to a multimeter or a similar device to make contact with the ECM pin at J1-66 through the vacant space in the J1 connector.

  1. While observing the status of the active CID 0356 FMI 05 diagnostic code, ground the other end of the 7X-1710 Multimeter Probe to frame ground.

Expected Result:

The CID 0356 FMI 05 diagnostic code is no longer active. A CID 0356 FMI 06 diagnostic code becomes active when the ECM pin at J1-66 is grounded.

Results:

  • YES - The CID 0356 FMI 05 diagnostic code is no longer active. A CID 0356 FMI 06 diagnostic code has been activated after the ECM pin is grounded. The ECM has responded correctly to the grounded circuit condition in the solenoid circuit. The ECM is most likely not causing the problem.

    Reinstall the disconnected solenoid energize wire back into the correct spot in the ECM connector before proceeding to the next test step.

    Proceed to Test Step 4.

  • NO - The CID 0356 FMI 05 diagnostic code remains active. The status of the active diagnostic code does not change when the ECM pin for the solenoid is grounded.

    Repair: The ECM has not responded correctly to the grounded condition in the solenoid circuit. The operation of the ECM is not correct.Prior to replacing an ECM, always contact your dealership's Technical Communicator for possible consultation with Caterpillar. This consultation may greatly reduce repair time. If the ECM must be replaced, refer to Testing and Adjusting, "Electronic Control Module (ECM) - Replace".

    STOP

Test Step 4. CHECK THE STATUS OF THE DIAGNOSTIC CODE

  1. Inspect the harness connectors and clean the contacts of the harness connectors and check the wires for damage to the insulation that is caused by excessive heat, battery acid, or chafing.

  1. Perform a 45 N (10 lb) pull test on each of the wires that are associated with the sensor circuit.

  1. Reconnect all harness connectors. Make sure that the connectors are fully seated and the clips for each connector are completely fastened.

  1. The key start switch remains in the ON position.

  1. Operate the machine.

  1. Check the status of the CID 0356 FMI 05 diagnostic code.

Expected Result:

The CID 0356 FMI 05 diagnostic code is active.

Results:

  • YES - The CID 0356 FMI 05 diagnostic code is active. The diagnostic code has not been corrected.

    Repair: Check the circuit again. Use the Caterpillar Electronic Technician (ET) service tool, if available, in order to perform a "Wiggle Test" on the machine wiring harness. The wiggle test can detect momentary or intermittent shorts or opens in the machine wiring harness.If the cause of the problem is not found in the machine harness, the ECM may have failed. This is unlikely as the ECM responded correctly to the grounded condition in the previous test step.Verify that all possible causes of the diagnostic code have been investigated. Exit this procedure and perform this procedure again.Prior to replacing an ECM, always contact your dealership's Technical Communicator for possible consultation with Caterpillar. This consultation may greatly reduce repair time. If the cause of the active diagnostic code is not found and the ECM must be replaced, refer to Testing and Adjusting, "Electronic Control Module (ECM) - Replace".

    STOP

  • NO - The CID 0356 FMI 05 diagnostic code is not active. The diagnostic code does not exist at this time.

    Repair: The initial diagnostic code was probably caused by a poor electrical connection at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.

    STOP

Caterpillar Information System:

279C, 279C2, 289C, 289C2 and 299C Compact Track Loaders, 287C, 277C, 277C2, 287C2 and 297C Multi Terrain Loaders and 246C, 256C, 262C, 262C2 and 272C Skid Steer Loaders Machine Electronic Control System MID 039 - CID 0356 - FMI 03
2012/02/27 A New Serviceable Accumulator is Available {5077}
770 and 772 Off-Highway Trucks Automatic Lubrication System Lubrication System
Installing the 258-3639 Backhoe Mounting Gp (Kit) or the 367-9770 Backhoe Mounting Gp (Kit){6504} Installing the 258-3639 Backhoe Mounting Gp (Kit) or the 367-9770 Backhoe Mounting Gp (Kit){6504}
2006/05/08 A New Location for the Dipstick is Now Used on the Rotor Transmission on Reclaimer Mixers {3030}
773F Off-Highway Truck and 775F Off-Highway Truck Power Train Relief Valve (Torque Converter Outlet) Pressure - Test and Adjust
325D Material Handler Circuit Breakers - Reset
773G and 775G Off-Highway Truck Power Train Relief Valve (Torque Converter Inlet) Pressure - Test
1390 Track Feller Buncher Hub Oil Level (Flexxaire Fan) - Check
120M, 12M, 140M, 14M, 160M and 16M Motor Graders Implement Electronic Control System MID 082 - CID 2113 - FMI 04
120M, 12M, 140M, 14M, 160M and 16M Motor Graders Implement Electronic Control System MID 082 - CID 2113 - FMI 03
2006/10/30 Improved Hoist Cylinders Are Used {5102}
279C, 279C2, 289C, 289C2 and 299C Compact Track Loaders, 287C, 277C, 277C2, 287C2 and 297C Multi Terrain Loaders and 246C, 256C, 262C, 262C2 and 272C Skid Steer Loaders Machine Electronic Control System MID 039 - CID 0356 - FMI 06
279C, 279C2, 289C, 289C2 and 299C Compact Track Loaders, 287C, 277C, 277C2, 287C2 and 297C Multi Terrain Loaders and 246C, 256C, 262C, 262C2 and 272C Skid Steer Loaders Machine Electronic Control System MID 039 - CID 0356 - FMI 13
279C, 279C2, 289C, 289C2 and 299C Compact Track Loaders, 287C, 277C, 277C2, 287C2 and 297C Multi Terrain Loaders and 246C, 256C, 262C, 262C2 and 272C Skid Steer Loaders Machine Electronic Control System MID 039 - CID 2474 - FMI 13
770 and 772 Off-Highway Truck Operation Information
CS56, CS64, CS74, CS76, CP56, CP64, CP74 and CP76 Vibratory Soil Compactors Final Drive Planetary (Drum) Oil - Change
CS56, CS64, CS74, CS76, CP56, CP64, CP74 and CP76 Vibratory Soil Compactors Final Drive Planetary (Drum) Oil - Check
CS56, CS64, CS74, CS76, CP56, CP64, CP74 and CP76 Vibratory Soil Compactors Final Drive Planetary (Drum) Oil Sample - Obtain
120M, 12M, 140M, 14M, 160M and 16M Motor Graders Implement Electronic Control System MID 082 - CID 2165 - FMI 03
120M, 12M, 140M, 14M, 160M and 16M Motor Graders Implement Electronic Control System MID 082 - CID 2165 - FMI 05
120M, 12M, 140M, 14M, 160M and 16M Motor Graders Implement Electronic Control System MID 082 - CID 2165 - FMI 06
120M, 12M, 140M, 14M, 160M and 16M Motor Graders Implement Electronic Control System MID 082 - CID 2165 - FMI 13
C9 Marine Engines and C9 Marine Generator Sets Unit Injector Hydraulic Pump
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.