Illustration 1 | g01376964 |
Illustration 2 | g01362478 |
(1) Torque for the 48 bolts ... 1000 ± 125 N·m (740 ± 90 lb ft)
(2) Torque for the six nuts ... 1000 ± 125 N·m (740 ± 90 lb ft)
(3) Torque for the two fittings ... 16 N·m (12 lb ft)
(4) Torque for the two O-ring plugs ... 82 + 8 N·m (60 + 6 lb ft)
(5) Torque for the O-ring plugs ... 210 + 20 N·m (155 + 15 lb ft)
(6) Torque for the eight nuts ... 1000 ± 125 N·m (740 ± 90 lb ft)
(7) Torque for the 44 bolts ... 210 ± 40 N·m (155 ± 30 lb ft)
Note: After tightening the bolts, turn the bolts for an additional 120 ± 10 degrees.
(8) Apply 6V-6640 Sealant between mating surfaces of cover and trunnion support.
(9) Torque for the pressure relief fitting ... 16 N·m (12 lb ft)
(10) Torque for the magnetic plug ... 210 + 20 N·m (155 + 15 lb ft)
(A) Outside diameter of trunnion ... 265.60 ± 0.08 mm (10.457 ± 0.003 inch)
Inside diameter of the new sleeve bearing ... 266.70 ± 0.41 mm (10.500 ± 0.016 inch)
(B) Inside diameter of trunnion support ... 289.65 ± 0.10 mm (11.404 ± 0.004 inch)
Outside diameter of the new sleeve bearing ... 290.00 ± 0.15 mm (11.417 ± 0.006 inch)
(C) Inside diameter of trunnion support ... 246.00 ± 0.10 mm (9.685 ± 0.004 inch)
Outside diameter of the new sleeve bearing ... 246.00 ± 0.15 mm (9.685 ± 0.006 inch)
(D) Outside diameter of housing ... 228.70 ± 0.08 mm (9.004 ± 0.003 inch)
Inside diameter of the new sleeve bearing ... 229.46 ± 0.41 mm (9.034 ± 0.016 inch)