Removal Procedure
NOTICE |
---|
Keep all parts clean from contaminants. Contaminants may cause rapid wear and shortened component life. |
NOTICE |
---|
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to Special Publication, NENG2500, "Caterpillar Tools and Shop Products Guide" for tools and supplies suitable to collect and contain fluids on Caterpillar products. Dispose of all fluids according to local regulations and mandates. |
- Drain the coolant from the cooling system into a suitable container for storage or disposal. Refer to the OEM for the approximate capacity of the cooling system. Refer to Operation and Maintenance Manual, "Cooling System Coolant (DEAC) - Change" or Operation and Maintenance Manual, "Cooling System Extended Life Coolant - Change".
- Remove two bolts (1) from water temperature regulator housing (5) .
Illustration 1 | g00825537 |
- Remove cover (2) and gasket (4) for the water temperature regulator (3) .
- Remove water temperature regulator (3) from the water temperature regulator housing (5) .
- Remove all debris and gasket material from the mating surfaces of cover (2) and water temperature regulator housing (5). Use a new gasket for assembly.
- Inspect water temperature regulator (3) for wear or damage. If the water temperature regulator is worn or damaged, use a new part for replacement. Refer to Testing and Adjusting, "Water Temperature Regulator - Test" for more information on testing the water temperature regulator.
Installation Procedure
NOTICE |
---|
Keep all parts clean from contaminants. Contaminants may cause rapid wear and shortened component life. |
- Install water temperature regulator (3) to water temperature regulator housing (5) .
Illustration 2 | g00825537 |
- Position a new gasket (4) and cover (2) for water temperature regulator (3) on water temperature regulator housing (5) .
- Install bolts (1) to cover (2). Tighten the two bolts for the cover to a torque of 14 N·m (10 lb ft).
- Fill the cooling system with coolant to the correct level. Refer to Operation and Maintenance Manual, "Refill Capacities" for more information.